power pole contact composition
3 NO
Rated working current [Ie]
80 A 60 °C) on <= 440 V AC AC-1 for power circuit
65 A 60 °C) on <= 440 V AC AC-3 for power circuit
Control circuit voltage
230 V AC 50/60 Hz
Auxiliary contact type
1 NO + 1 NC
We can also provide the following models
8702SEA2V07P2
8502SQR3V01X01
8903SHT1V42X01
8903SCW1V01P2
8502SEA2V06P2
8502SAH2V02P1
8903SYG1V42P1
8702SET2V81P1
8702SHF3V08S
8903SCW2V08P2
8702SXG2V07C
8702SZG1V42X01
8903SJA2V81P1
8502SMR3V08X01
8702SYR4V42E
8702SGA2V07FF4T
8903LF20V04
8502SYW1V81S
8702SCG3V81F4T
8903SXF2V07S
8502SFO1V81E
8702SZR1V01S
8903SBF1V01P1
8702SBT3V01S
8702SQF4V42F4T
8903SZH3V42P1
8702SXF2V08
8502SVG1V07
8502SZA2V01X10
8903SYW1V02P2
8702SFG3V08C
8903SVO4V02C
8702SBA1V81P2
8702SJW2V06P2
8903SHO2V07A
8702SDW1V08P1
8903SAW2V02
8903SHR3V01FF4T
8502SAT4V42P1
8903SBT2V81C
8502SVH4V01P2
8502SGR3V02H
8702SDR2V07FF4T
8502SDH2V08X10
8702SBA2V08F4T
8702SFA3V42FF4T
8903SVT1V42E
8502SMF3V07H
8502SGO4V07E
8903SMG91V02
8903SGG3V81E
8903SQO2V01FF4T
8702SBA1V08FF4T
8903SPW1V08C
8502SYW3V01
8702SQR2V06A
8702SVR4V01A
8702SHH3V42F4T
8903SVA4V01P1
LC1K06105T7
8903SAW2V07X10
8702SQT2V07P1
8502SQT3V08E
8903LXG1200V85FF4T
8903SQG3V07
8903SXW2V81P2
8702SMT2V07C
8702SBH2V81FF4T
8903SZG2V08E
8502SAW4V81C
8702SYG2V81S
8903SQW1V81A
8702SEA1V06H
8702SFT3V01F4T
For more information,please contact us freely
Schneider Contactor LC1D65P7C
People who bought this item also viewed
Fuji Contactor SC-0RM
Togami Contactor CLK-15H31-P4BL
RIKEN Contactor RAB-125N
Togami Contactor RSK-12H
Schneider Transformer ABT7PDU010B
Fuji Fuse CR6L-150/UL
TYCO Relay R10-E1X2-S800
UniOhm Resistor 0805W8F270JT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TOWARD Relay HRR2-1A-12
SMC Solenoid Valve SY5120-3LZD-C4
KOGANEI Solenoid Valve 240-4E1-PS-L
MARUYAMA Piston Pump MW150-011
Panasonic Servo Motor MSME041S1S
Recent related posts
-
09/10/2020
Afternoon tea problems often exist in air conditioning design
The author of okmarts.com came into contact with the HVAC engineering design of some design institutes, and compared the "Code for Design of Heating, Ventilation and Air Conditioning"
-
10/29/2021
VFD Troubleshooting: 10 Simple Methods to Master
At present and in the future, the maintenance of the electrical control equipment, VFD (Variable Frequency Drive) will become the professional knowledge that all electricians need to master.
-
08/11/2020
Pay attention to these details. The air energy heat pump can be used for more than 10 years.
In a few months, the northern heating season will officially begin. In addition to central heating, this year's "coal-to-electricity conversion" has also received much attention.
-
11/21/2022
What are Centrifugal Fans Used for?
The centrifugal fan is a device that relies on the input mechanical energy to increase the pressure of the air and discharge the air.
-
09/03/2020
Introduction of simple pressure vessel and fixed pressure vessel for air compressor gas storage tank
As the fourth most widely used energy source, compressed air is second only to traditional energy sources such as electric energy. As a necessary product for air compressors, compressed air is widely used in various fields of national production and life in my country.
-
01/06/2021
Parts of the Reciprocating Compressor
Parts of the Reciprocating Compressor Cylinder, Piston, Connecting Rod, Crankshaft: Parts of Reciprocating Compressor Introduction Now that we have seen the principle of working of the reciprocating compressor, let us see the various parts of the compr 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ
-
07/19/2020
The principle structure, advantages and disadvantages of scroll refrigeration compressor
Principle: The scroll line pattern of the moving plate and the static plate are the same, but the phase difference is 180°C; they mesh to form a series of closed spaces; the static plate does not move, and the moving plate revolves around the center of the fixed plate with the eccentricity as the radius. When the moving disc revolves, it meshes in sequence, so that the crescent-shaped area is continuously compressed and reduced, so that the gas is continuously compressed and finally discharged from the center hole of the static disc
-
12/20/2023
AC Fan Won't Turn off (Troubleshooting Guide)
The air conditioning system can be a true lifesaver during sweltering summers and chilling winters, providing comfort and respite from extreme temperatures.
-
09/07/2020
An article to fully understand the principle, failure and maintenance of nitrogen compressors
Nitrogen compressors are mainly used in various industrial needs. Pipes are used to connect the original air inlet of the nitrogen compressors and the balance gas tank. When the sealing performance of the sealing box is not very good, the pipeline provides a certain pressure ,
-
09/25/2023
Chilled Water System: Basics, Working Principle Diagram, Types and More
A chilled water system is a type of HVAC (heating, ventilation, and air conditioning) system that provides cooling through the circulation of chilled water.