Output: NPN
Connect: M12
Schneider Sensor XS518BLNAM12
People who bought this item also viewed
Schneider Sensor XS7D1A1DAL2
Honeywell Sensor P8000A0016G
Banner Sensor DF-G3IR-PS-Q5
Honeywell Sensor H7015B1020
Honeywell Sensor P7620C0042A
Endress Hauser Transmitter PMC71-ABA1E2CPAAU
Siemens Flame Detector FDF241-9
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LNTECH Light Curtain SFA140405
Siemens Contactor 3RT2017-1AR62
IFM Sensor TM5101
Siemens Circuit Breaker 3WT8121-5UG00-0AA1
Recent related posts
-
07/16/2020
Main features of semi-closed scroll compressor
1. On-site maintenance: The shell of the half-sealed scroll compressor can be disassembled, and the horizontal cast iron body is fixed by bolts. 2. Patented flexible scroll technology: compact structure, extremely low vibration-quiet operation and higher tolerance to liquids and magazines.
-
08/14/2020
How does the cold storage refrigeration system supplement and discharge refrigerant
The cold storage refrigeration system must ensure that the refrigerant is dry when adding refrigerant (only applicable to fluorine refrigerant refrigeration systems),
-
04/12/2023
How to Tell if Refrigerator Compressor is Bad
The compressor is the core component of the refrigerator. If the fridge compressor doesn't work, the whole fridge won't work either. So what can cause a refrigerator compressor to fail?
-
07/04/2020
Introduction of the models such as the MT-100 and other hermetic compressors
Introduction of the models such as the MT-100 and other hermetic compressors The picture shows the fully enclosed compressor MT-100, which is installed by the customer. Meiyou Le Maneurop hermetic compressor detailed introduction;
-
08/07/2020
What does air conditioning vrv mean How to choose an air conditioner
Air conditioners are a concern that every family will choose, and there are more and more types of air conditioners. Many people must pay attention to the above identification problems when buying air conditioners,
-
06/14/2020
The difference between air compressor and refrigeration compressor
The air compressor is the same as the refrigeration compressor in that it is the same compressor, the difference is that its working principle and working medium are different.
-
06/22/2020
Which refrigerator is better
The two cooling methods of the refrigerator are good. From the perspective of defrosting, the air-cooled refrigerator will perform better, because the air-cooled refrigerator uses forced air convection to cool the temperature. It reaches the expected temperature, and it is not easy to frost. The direct-cooled refrigerator absorbs heat by the evaporator to reduce the temperature, and it is easy to condense the frost.<img src="{{media url="magefan_blog/Which_refrigerator_is_better.jpg"}}" alt="" />
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
11 common problems in refrigeration compressors, do you know these
11 common problems in refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
06/14/2020
What's going on with frost during refrigeration compressor operation
Whether the compressor will frost depends on the evaporation temperature of the system and the superheat of the return air. The dry storage evaporator system of cold storage and refrigerator freezer, the refrigeration system under standard working conditi 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠