Power (W) 20W
Stroke Frequency 120 Stroke/min
Pump head material PVDF
Valve ball material Ceramics
Diaphragm material PTFE
Injection valve PVDF
Bottom valve filter PVDF
installing support
Vertical type
Pressure: Low Pressure
Power: Electric
SEKO Diaphragm Pump AKS600
People who bought this item also viewed
SEKO Diaphragm Pump MS1A094C21B4080
GRACO Diaphragm Pump Husky515 D52911
Iwaki Diaphragm Pump EHN-B11SH9R
ARO Diaphragm Pump 6661T3-3EB-C
Becker Vacuum Pump DT4.16/3
Iwaki Magnet Pump MD-70RM
MASTRA Water Pump 4SP8-10
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNX Sensor RX-LS200
IDEC Input Output Module FC6A-T16P3
Recent related posts
-
08/13/2021
How to Find Low Side of Your Refrigerator Compressor
The compressor of a refrigerator plays a key role in the cooling effect of the refrigerator, as well as the refrigeration cycle.
-
06/13/2020
Basic knowledge and role of refrigeration oil
The function and classification of refrigeration oil and the requirements of refrigeration equipment for refrigeration oil
-
08/20/2020
Solution to condensation on air outlet of air conditioner
Part 1: Causes of condensation at the air outlet 1. Theoretical analysis of condensation: First of all, we must first understand the cause of condensation and why it occurs.
-
07/15/2020
ZP61K5E-TF55.1 HP 60Hz (R410A) air-conditioning operating conditions Emerson Copeland compressor
The editor today will introduce the Emerson Copeland compressor ZP61K5E-TF5, which is suitable for R410A refrigerant at 60Hz three-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 5.1 hp. For other technical parameters, please download the product manual on our company website for self-inquiry.
-
08/14/2020
Factors affecting the boiling heat transfer of refrigerant liquid
In the evaporator, the heat of the cooled medium is transferred to the refrigerant through the heat transfer wall, so that the liquid refrigerant absorbs heat and vaporizes.
-
06/24/2020
Reasons and solutions of refrigerator not cooling
In the use of refrigerators, when there are more or less problems, I believe many people have encountered the reason why the refrigerator at home does not cool. What will you do when you encounter this situation? How much do you know about the reasons for the refrigerator not cooling? What? The following editor will introduce the reasons and solutions for the refrigerator not cooling, I hope to help you.
-
11/26/2021
Basics of ASHCROFT Pressure Transmitter - Performance Index, Wiring, Thread Type, Unavoidable Inaccuracies and Mounting
ASHCROFT pressure transmitter is one of the most commonly used transmitters in industrial applications.
-
12/09/2021
Top 10 Brands of HMI Worldwide
HMI is the abbreviation of human machine interface, which is also known as user interface. It is the medium of interaction and information exchange between the system and users.
-
06/20/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
12/07/2023
Air Cooling and Liquid Cooling: Introduction to Data Center Cooling System Technology
Most of the electrical energy consumed during the operation of electronic information equipment in the data center is converted into waste heat.