7A:Recommended Operating Voltage [Vdc]:1-72
Absolute Maximum Rating [Vdc]:100
Maximum Off-State Leakage Current @ Rated Voltage [mA]:0.1
Maximum Load Current [Adc]:60
Minimum Load Current [mA]:5
Maximum Surge Current (10msec) [Adc]:180
Maximum On-State Voltage Drop @ Rated Current [Vdc]l:0.6
Maximum On-State Resistance [RDS-ON] [Ohms]:0.01
Thermal Resistance Junction to Case (Rjc) [°C/W]:0.34
Minimum Heat Sink for Rated Current @ 40°C [°C/W]:1
Maximum Pulse Width Modulation Frequency [Hz]:1000
12A:Recommended Operating Voltage [Vdc]:1-72
Absolute Maximum Rating [Vdc]:100
Maximum Off-State Leakage Current @ Rated Voltage [mA]:0.2
Maximum Load Current [Adc]:80
Minimum Load Current [mA]:5
Maximum Surge Current (10msec) [Adc]:220
Maximum On-State Voltage Drop @ Rated Current [Vdc]l:0.7
Maximum On-State Resistance [RDS-ON] [Ohms]:0.01
Thermal Resistance Junction to Case (Rjc) [°C/W]:0.008
Minimum Heat Sink for Rated Current @ 40°C [°C/W]:0.5
Maximum Pulse Width Modulation Frequency [Hz]:900
20A:Recommended Operating Voltage [Vdc]:1-72
Absolute Maximum Rating [Vdc]:100
Maximum Off-State Leakage Current @ Rated Voltage [mA]:0.3
Maximum Load Current [Adc]:100
Minimum Load Current [mA]:5
Maximum Surge Current (10msec) [Adc]:330
Maximum On-State Voltage Drop @ Rated Current [Vdc]l:0.5
Maximum On-State Resistance [RDS-ON] [Ohms]:0.005
Thermal Resistance Junction to Case (Rjc) [°C/W]: 0.27
Minimum Heat Sink for Rated Current @ 40°C [°C/W]:0.5
Maximum Pulse Width Modulation Frequency [Hz]:800
INPUT:
Control Voltage Range 3.5-32 VDC
Maximum Reverse Voltage -32 VDC
Minimum Turn-On Voltage 3.5 VDC
Must Turn-Off Voltage 1 VDC
Minimum Input Current (for on-state) 10 mA
Maximum Input Current 15 mA
Nominal Input Impedance Current Regulated
Maximum Turn-On Time [μsec] 100
Maximum Turn-Off Time [μsec] 100
Sensata-Crydom Relay D1D60
People who bought this item also viewed
SIEMENS Relay 3TK2824-1AL20
Riken Relay RAB-150N
JEL Relay S1C-225WDV
PARKER Relay SCPSD-400-14-27
CHINT Transformer JBK4-500
GE Circuit Breaker FGN46KA350LLF
Fuji Contactor SC-E4P-G
CITEL Surge Protection Device DS44S-280
Littelfuse Fuse SPF30
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TCS Oil Seal TC 25*47*10
Daikin Air Conditioner FVY125DQV2CB(R4)
Mitsubishi Compressor KH165VLRC
SIEMENS Servo Drive 6SL3120-1TE24-5AA3
MitsubishiServo DriveMR-H100A
Panasonic PLC FP2-X16D2
Festo Air Cylinder DNC-63-310-PPV-S6
Recent related posts
-
01/26/2024
Computer Room Air Conditioning: Work Principle, Characteristics and Technical Requirements, Benefits
Computer room air conditioners (CRACs), to put it simply, are air conditioners dedicated to computer rooms.
-
11/06/2023
Should the Radiator Fan Turn On When the AC Is On?
When it comes to the operation of your vehicle's cooling system, the radiator fan plays a crucial role. It helps dissipate heat from the engine coolant, ensuring that the engine stays within its optimal temperature range.
-
06/30/2022
Types of Check Valve
Depending on the design of the check valve, they will operate slightly differently. The most common check valve is a spring loaded in-line check valve, however, we will discuss multiple types below.
-
09/20/2020
ABB motor low price spot limited time
Shanghai ABB Motor's okmarts.com's ABB motor storage-type spot supplier, was established on Chengdu Airport Road, highway, canal and airport to the whole country. The company has a high-quality, skilled and dedicated team of 30 people.
-
09/15/2020
Advantages and applicable fields of silent oil-free air compressor
Introduction to the advantages of silent oil-free air compressors and applicable fields When it comes to air compressors, everyone seems to remember the roar of motors that have a great impact on our lives and work, and because of the shortcomings of high noise, the scope of use of air compressors has great limitations.
-
07/25/2020
This is the "3 times", "8 steps" and "5 keys" of central air conditioning installation~~
It is not an exaggeration to say that the central air conditioner is installed with 3 points and 7 points for quality. The central air conditioner needs to be properly matched with the interior decoration. In fact, the equipment itself is only a "semi-finished product".
-
07/25/2020
Oil pressure protection? High and low voltage protection? Thermal relay protection? Come and see if the automatic control appliance fails
There are two types of failures in the automatic control of refrigeration devices: one is caused by the failure of the refrigeration system; the other is caused by automatic control, electrical component failure, and improper debugging.
-
06/14/2020
Trouble analysis and elimination of piston refrigeration compressor
Trouble analysis and elimination of piston refrigeration compressor Trouble analysis and elimination of piston refrigeration compressor 1) Large oil consumption of compressor Reason: The gap between the bearing, oil ring, cylinder and piston 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់
-
09/23/2020
Automatic control scheme for multiple adsorption dryers and air compressors
With the development of modern industry and the improvement of automation level, various industries have higher and higher requirements for air supply, purification level, automatic control, and continuous and reliable air supply of air compressor stations.
-
08/16/2020
What are the tasks that water-cooled chillers need to perform regularly
When using a water-cooled chiller, due to environmental or water quality issues, which will affect the normal operation of the equipment, it is necessary to perform some work on the water-cooled chiller regularly to maintain a stable working state and reduce the occurrence of failures.