VM320 valves series: 3/2way
Voltage : 24VDC
SHAKO Solenoid Valve VM320-9
People who bought this item also viewed
CKD Solenoid Valve 4SB019-C3
SHAKO Solenoid Valve PU225A-06-S9
SHAKO Solenoid Valve BM520-02-D1
SHAKO Solenoid Valve BM520-02-S9
SHAKO Solenoid Valve PU225A-14-S
MAC Solenoid Valve 411A-DOA-DM-DDAJ-1KD
CKD Solenoid Valve PDV3-25A-N2C-DC24V
CHELIC Solenoid Valve SNK-6102
Danfoss Transmitter 060G3007
Danfoss Solenoid Coil BF110CS
REXROTH Overflow Valve DBDH30P10B/315
NACHI Piston Pump PZS-6A-180N4-10
ALBERT Vane Pump SQP32-39-17VQ-1AA-18
Boden Gear Pump BHP3A1D100C1L1
LEEMIN Filter LH0240R030BN3HC
Danfoss Sight Glass SG3S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder SCD40X245S
Recent related posts
-
06/25/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
06/14/2020
Will the compressor car refrigerator affect the car
The weather has recently become hot. Many friends came to me and asked me how to get an Indell compressor car refrigerator on the car? Will it affect the car battery? I thought it would be the same. When the demand for car refrigerators is getting hotter, 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི
-
01/26/2023
How to Maintain a Pressure Transmitter
In order to prolong the service life of the pressure transmitter and reduce the error, regular inspection and maintenance are recommended, such as weekly inspection.
-
09/04/2020
The difference between ordinary asynchronous motor and variable frequency motor
1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which cannot fully meet the requirements of variable frequency speed regulation
-
06/14/2020
Top 10 common faults in maintenance and debugging of refrigeration systems
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦
-
07/02/2020
Compressor operation in the heart of the refrigeration system in 2020
Compressor operation in the heart of the refrigeration system in 2020 A compressor is a fluid machine that raises low-pressure gas to high-pressure gas. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor, and discharges high-temperature and high-pressure refrigerant gas to the exhaust pipe to provide power for the refrigeration cycle, thereby achieving compression-condensation (heat release) )-Expansion-evaporation (heat absorption) refrigeration cycle.
-
08/17/2020
Comparison of advantages and disadvantages of dry evaporator and flooded evaporator
The refrigerant of the dry expansion evaporator evaporates in the tube. The superheat at the outlet end of the evaporator is usually about 5 to 10K. The expansion valve uses the superheat detected by the temperature sensor to adjust the refrigerant flow r碌7館2 䀀 締眪湠眷 V
-
08/28/2023
Heat Pump Not Turning On: Troubleshooting Guide
Heat pumps are a popular HVAC system for homeowners, thanks to their energy efficiency and ability to provide both heating and cooling.
-
07/24/2020
Piston refrigeration compressor
The structure of the piston refrigeration compressor<br></br> Piston refrigeration compressor is mainly composed of three parts: working chamber part, machine base part and auxiliary system lubrication, cooling, etc.<
-
06/14/2020
After the Mitsubishi air conditioner is turned on, the indoor compressor does not rotate and cannot be cooled
Fault phenomenon: After a Mitsubishi SRC285cENF air conditioner is turned on, the indoor fan operates normally, and the indoor compressor does not rotate and cannot be cooled.