Rated VAC: 110(100V~120V)
Rated Input Amp: 0.07/0.06
Rated Speed RPM: 2400/2550
Max. Air Flow: 1.08/1.10 m?/min
Shengkwei FAN SK938AP-11-2
People who bought this item also viewed
Sanyo Denki Fan 109L5724H501
SUNON Fan PFC0321B1-C01U-S99
ORION Fan OA109AP-11/22-2WB
Delta Fan ASB0305HP-00CP4
Danfoss Compressor MTZ50HK4CBE
APC Power Supply SRC8000XLCIH
TRIAD Transformer CSE5-100701
GE Circuit Breaker FE36MC060JF
Fuji Contactor SF12BAA
FANUC Electric Motor A06B-1408-B100
Danfoss Sight Glass SGI 12S
Beckhoff Coupling Module BK3120
KUDOM Relay KSQE380D40
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Nemicon Encoder OEK-50-1C
Festo Air Cylinder ADVU-80-15-A-P-A
SUNX Sensor RT-410R-1
CHANTO Air Cylinder ASR40X200
Dwyer Transmitter 682-3
Recent related posts
-
06/13/2020
What to do if the screw chiller compressor is damaged
The compressor is the core component of the chiller. Damage to the compressor is a serious fault that needs to be dealt with in time, otherwise the chiller will not work. Today, the editor will introduce the knowledge and process of handling damaged screw 器2 䀀
-
07/05/2020
Global Portable Air Compressor Market 2020 Players, Demand And Supply: Stanley Black&Decker, Fini Compressors, Powermate and Senco
The Global Portable Oil-Free Air Compressors Market report offers a quantitative analysis of the world Portable Oil-Free Air Compressors market with respect to a series of elements such as deep estimations, present industry trends, Portable Oil-Free Air Compressors market share, and key dynamics of the Portable Oil-Free Air Compressors market size from 2020-2026 in order to recognize the leading Portable Oil-Free Air Compressors market opportunities.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/13/2020
Acceptance standards after the cold storage design and installation are completed
A newly built cold storage, when it's time for acceptance, it will definitely be anxious. How can it be accepted to ensure quality and quantity? The editor of okmarts.com will briefly introduce it below.
-
02/28/2021
Characteristics of permanent magnet synchronous servo motor
(1) High power factor and high efficiency; (2) Simple structure and reliable operation; (3) Small size, light weight and small loss. Compared with other kinds of motors
-
09/04/2020
Have you heard of the 6S management of the compressor station on-site
For compressor users, on-site management is one of the daily management content of each enterprise.
-
06/13/2020
Electronic expansion valve
Electronic expansion valve The electronic expansion valve is a speed type and is used in an intelligently controlled inverter air conditioner. The advantages of the electronic expansion valve are: large flow adjustment range; high control accuracy; suita 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
08/02/2020
How to quickly calculate the cost of cold storage
Factors that determine the price of cold storage<br></br> cold storage unit: (cold storage unit size, cold storage unit brand, cold storage unit origin, cold storage unit type).
-
06/29/2020
How the compressor works
-
07/02/2020
The compressor lacks oil, so the harm is so great!
The compressor lacks oil, so the harm is so great! Compressors are complex machines that operate at high speeds. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, and pistons is the basic requirement for maintaining normal operation of the machine.