Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.4 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.28...0.4 A |
Suitable for induction motors with P | 0.09 kW |
Instantaneous overcurrent releases | 5.2 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.288 kg |
Circuit breaker size S0 for motor protection CLASS 10 A-release0.28...0.4 A Short-circuit release 5.2 A
Screw termina Standardswitching capacity Phased-out product Successor is SIRIUS3RV2 Preferred successor
type is 3RV2011-0EA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20 mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 0.4 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.28 - 0.4
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 0.4 A
operating power at AC-3
at 400 V rated value 90 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Siemens Circuit Breaker 3RV1021-0EA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV2011-4AA20
Siemens Circuit Breaker 3RV2011-0HA10
Siemens Circuit Breaker 3RV1011-0CA10
Siemens Circuit Breaker 3RV1021-1CA10
Schneider Circuit Breaker LV430630
Eaton Moeller Circuit Breaker LZMS3-A400
Siemens Circuit Breaker 3WN6071-0DB58-0AK1
CHINT Transformer JBK5-400
TROMBETTA Contactor 684-2461-212
Buss Fuse SC-40
Yageo Resistor RC0201FR-07390KL
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Evermore Tool for Metal Cutting SD16-15
INA Linear Guideway RWU100-E
SUNON Fan KDE2409PTB1-6A
Recent related posts
-
06/14/2020
Reliability-up (Compressors)
Reliability-up (Compressors)
-
07/12/2020
What semi-hermetic screw compressors are customers willing to pay for?
In the early years, many people felt that semi-hermetic screw compressors are expensive and have high technical threshold. Without semi-hermetic piston compressors, they are cheap and easy to use and maintain, so they are a bit daunted.
-
08/17/2020
Common failures of scroll chiller compressor
Scroll compressors are mainly used in air-cooled box chillers, water-cooled box chillers, open chillers, low temperature chillers, etc. It is said that the compressor is the heart of the chiller, so how can we operate to avoid the compressor from malfunct碌7館
-
08/17/2020
How to clean the return air duct of central air conditioning
Today, the editor of okmarts.com mainly introduces some of the most commonly used and basic cleaning procedures for central air-conditioning. I hope it will be useful to everyone!
-
08/20/2020
How to prevent moisture caused by steam penetration in cold storage projects
Under normal circumstances, excessive air humidity causes rapid growth of mold, moldy food, and corrosion of cold storage building materials. Therefore, the moisture-proof of cold storage projects is also particularly important.
-
09/16/2020
Application skills of air compressor using oil and gas separator
Abstract: The application technical requirements of the oil-gas separation core used in air compressors, and the problems that occur during the use of the oil-gas separation core are analyzed, and the matters to be noted before installation.
-
11/29/2021
Photoelectric Encoder on CNC Machines Troubleshooting and Solutions
It is an automatic machine tool with program control system. The control system can logically process the programs with control codes or other symbolic instructions, decode them and express them with coded numbers.
-
08/08/2020
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night
How much electricity does a 1.5-hp air conditioner need to work for 10 hours a night When the indoor temperature reaches the preset temperature, as long as the outdoor compressor and electric fan stop running, the indoor cabinet electric fan will continueﰨ2 䀀
-
08/03/2022
FANUC Spindle Amplifier Alarm Codes and Solutions (1)
FANUC CNC system has two mainstream servo drive amplifiers - αi and βi series servo drive amplifiers.
-
08/11/2020
The relationship between refrigerant and water in explosion-proof chemical air conditioning
Compared with ordinary air conditioners, the good explosion-proof performance of explosion-proof chemical air conditioners is an important factor in the selection of enterprises.