Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 2 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 1.4...2 A |
Suitable for induction motors with P | 0.75 kW |
Instantaneous overcurrent releases | 26 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.356 kg |
Circuit breaker size S0 for motor protection CLASS 10 A-release1.4...2 A Short-circuit release 26 A
Screw terminal Standardswitching capacity !!! Phased-out product !!! Successor is SIRIUS3RV2 Preferred
successor type is >>3RV2011-1BA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25 W
at AC in hot operating state per pole 2.8 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20
mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 2 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 1.4 - 2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 2 A
operating power at AC-3
at 400 V rated value 750 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 8 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Siemens Circuit Breaker 3RV1021-1BA10
People who bought this item also viewed
ABB Circuit Breaker GSH202 AC-C16
Siemens Circuit Breaker 3RV1021-4AA10
Siemens Circuit Breaker 3RV1011-1KA10
Siemens Circuit Breaker 3VU1300-1MG00
Siemens Circuit Breaker 3RV2021-4CA20
ABB Circuit Breaker GS201 AC-C16
Siemens Circuit Breaker 3RV2011-1GA20
Eaton Moeller Circuit Breaker KD35K
Siemens Circuit Breaker 3RV2011-0DA10
TRIAD Transformer TY-146P
Siemens Contactor 3RT1066-6PF35
OBO Surge Protection Device V50-B+C3+NPE-280
Raychem Fuse RGEF500 5A
TYCO Relay KHAU-17D18-110
Yageo Resistor RSF3WSJT-73-150R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
GMCC Compressor PH480X3C-8KUC1
Moeller Contactor DILK12-11(42V50HZ
MINAMOTO Water Pump 50CDLF16-16
PIZZATO Switch FP 731-M2
Recent related posts
-
06/14/2020
Do you know question and answer with refrigeration compressors?
1. Why control the impurity content and moisture content of the compressor and air conditioning system?
-
01/10/2024
Cooling Towers: Operation Methods, Maintenance & Usage Precautions
Cooling towers are critical equipment used in industrial and commercial areas to cool fluids. In order to ensure its effective operation, increase its lifespan and maintain safety, correct operation methods, maintenance and upkeep knowledge, and usage precautions are crucial. In this article, we will delve into these aspects.
-
06/14/2020
Relay protection concept and basic requirements
Before introducing relay protection, first introduce several working states of the power system (1) Normal working state It means that all the equality and inequality constraints of the power system are satisfied, indicating that the power system me 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
07/16/2020
Judgment of the failure of piston compressor in starting
Piston compressor It is a type of compressor commonly used in industrial refrigeration. Most piston compressors use a semi-closed shape, which is simple and convenient to maintain and repair. It is widely used in large supermarkets, cold stores, laboratories, and various refrigeration equipment.
-
07/04/2020
Talking about several common types of Copeland compressors
Talking about several common types of Copeland compressors Copeland compressors, which consist of casings, motors, cylinders, pistons, control equipment (starters and thermal protectors), and cooling systems, are used very often in air conditioning and cold storage.
-
07/18/2020
The advantages and disadvantages of screw refrigeration compressor
Power compressor is indispensable when refrigeration equipment is cooling. Such as chillers, chromatography freezers, ice machines, ultra-low temperature refrigerators, etc., their driving force is the refrigeration compressor, the entire refrigerant cycle is the refrigeration compressor
-
09/04/2020
Have you heard of the 6S management of the compressor station on-site
For compressor users, on-site management is one of the daily management content of each enterprise.
-
12/01/2022
How do Linear Guideways Work?
The linear guideway is a new type of rolling bearing for relative reciprocating linear motion. It uses the ball rolling between the guide rail
-
06/16/2020
Martin Rossen new global head of public affairs and communication at Danfoss
Martin Rossen will join Danfoss as Senior Vice President, Group Communication & Reputation 1st November, 2020, where he will be responsible for Danfoss’ global public affairs and communication activities. As of 1st November 2020, Martin Rossen takes on t 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
08/18/2021
How to Repair Your Servo Motor
First, you need to do the following things before starting the servo motor. Measure the insulation resistance (for low voltage motor it should not be less than 0.5m).