| Type | 3RV1 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 20 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 14...20 A |
| Suitable for induction motors with P | 7.5 kW |
| Instantaneous overcurrent releases | 260 A |
| Short-circuit breaking capacity | 50 kA |
| Weight approx. | 0.363 kg |
Circuit breaker size S0 for motor protection CLASS 10 A-release14...20 A Short-circuit release 260 A
Screw terminal Standardswitching capacity !!! Phased-out product !!! Successor is SIRIUS3RV2 Preferred successor
type is >>3RV2021-4BA10
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
General technical data
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 10.5 W
at AC in hot operating state per pole 3.5 W
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
protection class IP
on the front IP20
mechanical service life (switching cycles)
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typica 100 000
continuous current rated value 20 A
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 - +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 14 -20A
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating current
at AC-3 at 400 V rated value 20 A
operating power at AC-3
at 400 V rated value 7500 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 10 kA
at AC at 690 V rated value 4 kA
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 50022
height 97 mm width 45 mm depth 96 mm
Ask questions
(0/1,200)
- Q: Can I change the size or color of an item after placing an order?
A: If you need to change the size or color of an item after placing an order, please contact our customer service team as soon as possible. We will assist you in modifying the order if it hasn't been processed for shipping.
- Q: How can I participate in promotions or giveaways organized by sellers?
A: We regularly hold promotional events and organize giveaways and gift activities. You can follow our official announcements, emails, or social media channels to get information on how to participate and the details of these activities.
- Q: How can I provide feedback or share my shopping experience with you?
A: We highly value your feedback and would like to hear about your shopping experience. You can contact our customer service or provide feedback through the "Screenshot Feedback" feature on our website. We welcome your opinions and suggestions as they help us improve our services and better serve our customers.
Reviews
- S
Samuel Bankester
Sep 08, 2025
Siemens Circuit Breaker 3RV1021-4BA10It was a beautiful experience.HelpfulUnhelpful - W
Wade Johnson
Jul 28, 2025
Siemens Circuit Breaker 3RV1021-4BA10Everything was just as promised and exceeded my expectations.HelpfulUnhelpful - R
Robert Mundy
Dec 08, 2024
Siemens Circuit Breaker 3RV1021-4BA10I found the answer to my question.HelpfulUnhelpful - J
Jim Vinci
Sep 25, 2024
Siemens Circuit Breaker 3RV1021-4BA10I had no trouble with the order and it arrived on time.HelpfulUnhelpful - M
Matt Gregg
Sep 05, 2024
Siemens Circuit Breaker 3RV1021-4BA10Great, exactly as described.HelpfulUnhelpful - F
Fabián
Feb 23, 2024
Siemens Circuit Breaker 3RV1021-4BA10¡Encontré la pieza rápidamente!HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV1021-4BA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV1021-4BA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
ABB Circuit Breaker GSH202 AC-C16
Siemens Circuit Breaker Q120U
Siemens Circuit Breaker 5SY4640-8CC
Siemens Circuit Breaker 5SY4450-8CC
Siemens Circuit Breaker 5SY5201-6CC
Siemens Circuit Breaker 5SN4432-8CN
Terasaki Circuit Breaker AR440SB-R
TRIAD Transformer FP30-85
ALBRIGHT Contactor SW80A-1018T
Littelfuse Fuse 0154.800DR
OMRON Relay K8AK-AW2 24 VAC/DC
IRC Resistor 20190905 1W 152R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NSK Bearing 6916 CE
Copeland Compressor ZPV0962E-7X9-465
FYH Bearing UCFCX12
SKF Bearing 23228 EK
Copeland Compressor ZBD45KQE-TFD
HAYIGONG Tool for Metal Cutting 1.0mm
LYC Bearing 6030E-RZ
HYDROMAX Gear Pump HGP-22A-F11+11R