Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.32 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.22...0.32 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
0.22...0.32 A N-release 4.2 A screw terminal Standard switching
capacity with transverse auxiliary switches 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20 of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 ... +60 degrees centigrade
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
0.22 ... 0.32 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operating current rated value 0.32 A
operating current
at AC-3
at 400 V rated value 0.32 A
operating power
at AC-3
at 230 V rated value 40 W
at 400 V rated value 90 W
at 500 V rated value 120 W
at 690 V rated value 120 W
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
design of the auxiliary switch transverse
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A
at 120 V 0.5 A
at 125 V 0.5 A
at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A
at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 4.2 A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.32 A
at 600 V rated value 0.32 A
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit
current Ik < 400 A)
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97 mm
width 45 mm
depth 97 mm
required spacing
for grounded parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 400 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for live parts at 500 V
downwards 30 mm
upwards 30 mm
at the side 9 mm
for grounded parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
for live parts at 690 V
downwards 50 mm
upwards 50 mm
backwards 0 mm
at the side 30 mm
forwards 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
for main contacts
single or multi-stranded 2x (0,75 ... 2,5 mm?), 2x 4 mm?
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
at AWG conductors for main contacts 2x (18 ... 14), 2x 12
type of connectable conductor cross-sections
for auxiliary contacts
single or multi-stranded 2x (0,5 ... 1,5 mm?), 2x (0,75 ... 2,5 mm?)
finely stranded with core end processing 2x (0.5 ... 1.5 mm?), 2x (0.75 ... 2.5 mm?)
type of connectable conductor cross-sections at
AWG conductors for auxiliary contacts
2x (20 ... 16), 2x (18 ... 14)
tightening torque
for main contacts with screw-type terminals 0.8 ... 1.2 N.m
for auxiliary contacts with screw-type terminaals 0.8 ... 1.2 N.m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv 2
design of the thread of the connection screw
for main contacts M3
of the auxiliary and control contacts M3
Safety related data
B10 value
with high demand rate acc. to SN 31920 5 000
proportion of dangerous failures
with low demand rate acc. to SN 31920 50 %
with high demand rate acc. to SN 31920 50 %
failure rate FIT
with low demand rate acc. to SN 31920 50 FIT
T1 value for proof test interval or service life acc. to
IEC 61508
10 y
display version
for switching status Handle
Siemens Circuit Breaker 3RV2011-0DA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV1011-0CA15
Siemens Circuit Breaker 3RV5041-4KA10
Siemens Circuit Breaker 5SY4220-7
Siemens Circuit Breaker 3RV2021-0KA10
Siemens Circuit Breaker 3RV1011-0DA10
Siemens Circuit Breaker 3RV2011-1JA10
TRIAD Transformer F12-1000-C2
Schneider Contactor LP1K12015MD
Ferraz Shawmut Fuse BS217UT69V150
HONGFA Relay HFKM-012-1ZST(555)
UniOhm Resistor 1206W4J0432T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Profantec FAN P2082HSL
HONGFA Relay HFD42-5-L1SR
Sanyo Denki Fan 9GA0912G4021
Meas Transmitter M5154-000005-700BG
Recent related posts
-
06/18/2020
Application rate of air conditioning fans and how to clean and maintain
The air-conditioning fan is a new type, energy-saving, high efficiency, variable speed, low noise centrifugal fan. This type of fan has a compact structure, easy installation, small volume, large air volume, high pressure and low vibration. It is equipped with three-phase voltage regulation The device or frequency converter can implement stepless speed regulation. It is especially suitable for ventilating and ventilating places with strict noise requirements and large air volume changes. It is an ideal supporting product for air conditioning and purification industries.<img src="{{media url="wysiwyg/Application_rate_of_air_conditioning_fans_and_how_to_clean_and_maintain.jpg"}}" alt="" />
-
07/03/2020
Stationary Oil Free Air Compressor Market Analysis, Trends, Top Manufacturers, Share, Growth, Statistics, Opportunities & Forecast To 2026
Building & Construction Hold Over 20 % Share in Portable Air Compressor Market 2019 to 2027 June 25, 2020 No Comments Compressor Control SystemIndustrial Air CompressorPortable Air CompressorPortable Inverter GeneratorReciprocating CompressorRotary Screw Compressor
-
08/25/2020
How to correctly take out ammonia refrigerant when repairing refrigeration parts
First, prepare all tools and emergency supplies before operation. Such as ammonia tanks or a certain number of ammonia bottles, scales, connecting pipes, fitter tools, gas masks, rubber gloves and first aid medicines.
-
06/13/2020
Do you know several common refrigeration compressors
Among various types of refrigeration compressors, piston compressors are the earliest and still have more models. For example, semi-hermetic piston refrigeration compressors are widely used in refrigeration and refrigeration equipment. Common manufacturer 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ
-
07/18/2020
Fault analysis and treatment of excessive oil consumption of the refrigeration compressor of piston chiller
Commonly used chillers are divided into piston type, screw type, centrifugal type, and vortex type chiller according to the type of refrigeration compressor used. Their evaporators and condensers generally use shell and tube heat exchangers, the throttling device uses thermal expansion valves, the refrigerant is freon
-
06/13/2020
An article to understand the centrifugal compressor
With the rapid development of technology in my country's air compression industry, air compressors have greatly improved in structural layout and functional form. Centrifugal air compressors have become a new generation of air compression equipment. Since 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧҈ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理
-
03/02/2021
Application of servo motor
Machine tool manufacturing - lathe, planer, grinder, machining center, gear making machine, milling machine, etc Automobile manufacturing - engine parts production line, vehicle assembly line, engine assembly line, body welding line, testing equipment, etc Casting manufacturing - manipulator, converter tilting, mold processing center, etc
-
11/13/2022
How to Install an Industrial Exhaust Fan?
Factory production emits a lot of waste gas, and there are many workers gathered. For the sake of worker health and safety concerns, some exhaust fans are installed in factories to discharge exhaust gas.
-
08/30/2021
How to Fix a Refrigerator Compressor?
The refrigerator compressor is the core of a refrigerator and achieves the cooling effect. Due to the frequent use of the refrigerator
-
07/23/2020
R410a and R22 refrigerant comparison application and installation specifications
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.