Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 10 |
Number of Poles | 2 pole |
Setting range for thermal overload releases | 7...10 A |
Circuit breaker size S00 for motor protection, CLASS 10 A-release
7...10 A N release 130 A Spring-type terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
in networks with grounded star point between
main and auxiliary circuit
400 V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles)
typical 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
height 106 mm
width 45 mm
depth 97 mm
Siemens Circuit Breaker 3RV2011-1JA20
People who bought this item also viewed
Siemens Circuit Breaker 5SY6111-7
Siemens Circuit Breaker 3RV1011-0EA10
Siemens Circuit Breaker 3RV1041-4KA10
Siemens Circuit Breaker 3RV2011-1BA15
Siemens Circuit Breaker 3RV1011-1DA15
Terasaki Circuit Breaker XS30NB
Siemens Circuit Breaker 3RV2021-1JA10
Wurth Transformer 750813540
Schneider Contactor LC1N0910M5
OBO Surge Protection Device FLD 24
Littelfuse Fuse 0314040.MXP
Broyce Relay ELRM44V-10
UniOhm Resistor 0603WAF150JT5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
EPCOS Capacitor B32652A4394J
Mean Well Power Supply RPS-200-24
AirTAC Air Cylinder ACQ25X80S
Carel Temperature Controller PJEZY0H000
Siemens Sensor 3RG6014-3AF00
Recent related posts
-
03/18/2021
The working principle and the common wiring method of the servo drive
The servo drives, the motor under the command signal from a control system, so whether the drive can work normally or not directly affects the overall performance of the equipment. In the servo control system, the servo drive is equivalent to the brain, and the servo motor is equivalent to the hands and feet.
-
07/21/2020
11 common protection devices for refrigeration compressors
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
09/03/2020
Theoretical basis for appearance design of natural gas compressor
The modern design system is an open system, especially in terms of shape, color, and materials. Ergonomics, also known as ergonomics or ergonomics, originated in Europe and the United States
-
10/29/2021
VFD Troubleshooting: 10 Simple Methods to Master
At present and in the future, the maintenance of the electrical control equipment, VFD (Variable Frequency Drive) will become the professional knowledge that all electricians need to master.
-
08/20/2020
How to judge the fault based on the indicator light of the ice machine
1. The power indicator light keeps flashing quickly and the machine does not work: The cause of the failure: the water temperature probe is open. Repair method: Open the rear cover, open the cover of the electric control box above the compressor, find a three-core connector, check if there is any dropout or poor contact, then reconnect it.
-
08/20/2020
The difference between cross-flow cooling tower and counter-flow cooling tower
The so-called cross-flow cooling tower is a type of cooling tower that allows air to flow horizontally through the water spray filler, and the water dragon falls vertically from the top of the tower
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
09/12/2023
Hydronic Heat Pump Explained (Definition, Working Principle, Pros and Cons)
Hydronic heat pumps are a type of heat pump that are becoming increasingly popular in residential and commercial settings. They offer a number of advantages over traditional heating and cooling systems, including increased efficiency, reduced energy costs, and improved air quality.
-
07/21/2023
Heat Pump vs Air Conditioner: Which One is Right for You?
When it comes to cooling your home, you have two main options: a heat pump or an air conditioner. Both of these systems work to keep your home comfortable during hot weather, but there are some key differences between the two.
-
07/05/2020
Hitachi heat pump compressor
Does the compressor not start related to the four-way valve? There is no relationship between the compressor does not start and the four-way valve. Therefore, when the four-way valve coil is damaged, it will not cause the air-conditioning compressor to fail to start normally, nor will the compressor start normally after the good four-way valve coil is replaced.