Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 16 |
Number of Poles | 2 pole |
Setting range for thermal overload releases | 10...16 A |
Circuit breaker size S0 for motor protection, CLASS 10 A-release
10...16 A N-release 208 A Spring-type terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
insulation voltage with degree of pollution 3 at AC
rated value
690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400 V
height 119 mm
width 45 mm
depth 97 mm
Siemens Circuit Breaker 3RV2021-4AA20
People who bought this item also viewed
Siemens Circuit Breaker 3RV1021-4BA15
Siemens Circuit Breaker 3RV1041-4FA10
Siemens Circuit Breaker 3RV1011-1HA15
Siemens Circuit Breaker 3RV1041-4KA15
Terasaki Circuit Breaker S400-CF
Siemens Circuit Breaker 3RV1011-1KA10
Block Transformer STEU100/24
Siemens Contactor 3RT2015-2KA42
Littelfuse Fuse 0695015.PXPS
TYCO Relay OZ-SH-124L1
Schneider Resistor VW3A7750
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
THK Linear Guideway SRG30C1SS
BANDO Belt XL-638-14
E+E Transmitter EE160-HT3XXPBB/TX004
KRIWAN Controller Module SE-B2
SMC Solenoid Valve SY3220-5GZ-C6
Schneider Circuit Breaker EZD160M4100PN
Recent related posts
-
09/05/2020
What is the difference between single screw compressor and twin screw compressor
Single-screw and twin-screw manufacturing process of twin-screw is more complicated than single-screw in terms of structure, and the difference in service life and working efficiency is not very big,
-
08/05/2020
The difference between the three types of evaporators dry, flooded, and falling film evaporators
The refrigerant in the dry evaporator passes through the heat exchange tube, and the cold water runs outside the high-efficiency heat exchange tube. Such a heat exchanger has relatively low heat exchange efficiency,
-
07/02/2020
Baifuma Compressor How to define the stability of the compressor
Baifuma Compressor How to define the stability of the compressor Baifuma compressors have many characteristics, such as pressure ratio, efficiency, mass flow and additional energy. Another important feature is stability. Many people will ignore the stability of the compressor, which is a very bad thing.
-
09/04/2020
The difference between ordinary asynchronous motor and variable frequency motor
1. Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which cannot fully meet the requirements of variable frequency speed regulation
-
07/05/2020
Hitachi 2p cold storage compressor
How does the electronic expansion valve reduce the energy loss of the compressor during start and stop? When the compressor is stopped, the electronic expansion valve can completely close the valve to prevent the refrigerant from flowing from the condenser to the evaporator
-
06/18/2020
The main reason for the slow heating of air conditioners
The main reason for the slow heating of air conditioners There are several reasons for the slow heating of air conditioners: The dirt of the transpiration device and the condenser is too thick, which will cause air flow blockage, affect the heat declaration, and make the air conditioning heating a big discount. The filter is not cleaned for a long time<img src="{{media url="wysiwyg/The_main_reason_for_the_slow_heating_of_air_conditioners.jpg"}}" alt="" />
-
08/08/2020
Maintenance knowledge and failure methods of small combined cold storage
1. The cold storage door is not closed tightly. Please adjust the distance between the hinge and lock on the door and the storage body.
-
08/19/2020
How to speed up the evaporation and heat dissipation of cooling tower water
In the process of water cooling in the cooling tower, the water is formed into very small water droplets or very thin water film, which expands the contact area of water and air and prolongs
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.
-
01/29/2024
The Role of UPS and How to Solve Its Heat Dissipation Problem (UPS Cooling Fan)
(Uninterruptible Power Supply) is a power supply that contains an energy storage device. It is mainly used to provide uninterrupted power for some equipment that requires high power supply stability, such as a single computer, computer network system