Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 28 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 23...28 A |
Circuit breaker size S0 for motor protection, CLASS 10 A-release
23...28 A N-release 364 A screw terminal Standard switching
capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 13.25?W
at AC in hot operating state per pole 4.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
23?...?28?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 28?A
operating current
at AC-3
at 400 V rated value 28?A
operating power
at AC-3
at 230 V rated value 7?500?W
at 400 V rated value 15?000?W
at 500 V rated value 18?500?W
at 690 V rated value 22?000?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 25?kA
at 500 V rated value 5?kA
at 690 V rated value 2?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 55?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 4?kA
response value current
of instantaneous short-circuit trip unit 364?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 28?A
at 600 V rated value 28?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 2?hp
at 230 V rated value 5?hp
for three-phase AC motor
at 200/208 V rated value 7.5?hp
at 220/230 V rated value 10?hp
at 460/480 V rated value 20?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 400 V gL/gG 63 A
at 500 V gL/gG 63 A
at 690 V gL/gG 63 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 45?mm
depth 97?mm
Siemens Circuit Breaker 3RV2021-4NA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1031-4GB10
Siemens Circuit Breaker 3RV2021-1BA10
Siemens Circuit Breaker 3VA1463-5EF32-0AA0
Siemens Circuit Breaker 3RV2021-4PA10
ABB Circuit Breaker SH202-D50
Fuji Circuit Breaker EW50SAG-3P010
Siemens Circuit Breaker 3RV2011-1GA10
Wurth Transformer 750811116
Eaton Contactor DILER-40-G
Littelfuse Fuse 0218001.MXP
FULRD Relay FDR1 A4810 25A
UniOhm Resistor 0603WAJ0270T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Lenze VFD Frequency Converter EVS9330-ER
Schneider Circuit Breaker A9F19250
GMCC Compressor DA200S2C-10MT
Recent related posts
-
08/05/2020
How to solve the common old problems in the operation of chillers
In the pharmaceutical, food, chemical and other industries, process water cooling is required. The chiller has become a must-choice equipment for many industries.
-
08/19/2020
The difference between chilled water, cooling water and condensed water and the principle of refrigeration
The central air-conditioning host is composed of a compressor, an evaporator, a condenser, and a throttle valve. The compressor provides energy. The condenser reduces the temperature of the refrigerant from the compressor.
-
08/16/2020
The difference between duct air conditioner and split air conditioner
1. What is split air conditioner Split type is the name to distinguish it from the window machine. The compressor, condenser, evaporator and other components of the window air conditioner are all connected together.
-
08/08/2020
How much do you know about freezing oil
Although the refrigerating oil is only a small material, if you accidentally use inferior products, you can even burn the machine. I believe that many colleagues have often encountered it.
-
09/03/2020
The customer says the price is high, what should the air compressor seller do
After quoting customers, we often encounter such a problem, "Your price is too high". Strictly speaking, it is not a rejection of the question "your price is too high" raised by the customer. This is actually a positive signal.
-
06/13/2020
Screw compressor oil system workflow and common faults
Screw compressor oil system workflow and common faults 1. Working process of screw refrigeration unit The working process of screw refrigeration unit can be divided into refrigerant process and oil system process. Friends who are familiar with screw uni 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ـ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/10/2020
Air compressor selection and energy saving methods
I. Overview Among many commonly used energy sources, compressed air can be said to be one of the popular energy sources second only to electricity. Although the use of compressed air has not yet penetrated into ordinary households like electricity,
-
07/05/2020
Global Portable Air Compressor Market 2020 Players, Demand And Supply: Stanley Black&Decker, Fini Compressors, Powermate and Senco
The Global Portable Oil-Free Air Compressors Market report offers a quantitative analysis of the world Portable Oil-Free Air Compressors market with respect to a series of elements such as deep estimations, present industry trends, Portable Oil-Free Air Compressors market share, and key dynamics of the Portable Oil-Free Air Compressors market size from 2020-2026 in order to recognize the leading Portable Oil-Free Air Compressors market opportunities.
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
06/22/2023
What is a DC Compressor? A Comprehensive Guide
A DC compressor is an electrical compressor that is powered by direct current (DC) electricity.