Type | 3RV2 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.32 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.22...0.32 A |
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.22...0.32 A N-release 4.2 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5?W
at AC in hot operating state per pole 1.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.22?...?0.32?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 0.32?A
operating current
at AC-3
at 400 V rated value 0.32?A
operating power
at AC-3
at 230 V rated value 40?W
at 400 V rated value 90?W
at 500 V rated value 120?W
at 690 V rated value 120?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 4.2?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.32?A
at 600 V rated value 0.32?A
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Siemens Circuit Breaker 3RV2111-0DA10
People who bought this item also viewed
Siemens Circuit Breaker 3RV1021-0DA10
Siemens Circuit Breaker 5SY6225-7CC
Siemens Circuit Breaker 5SY6116-7CC
Siemens Circuit Breaker 3RV2021-1BA10
Siemens Circuit Breaker 3RV1011-1HA10
Fuji Circuit Breaker BW32SAG-2P015
Terasaki Circuit Breaker S250-SF
Siemens Circuit Breaker 3WN6361-0GV58-0AK1
Delixi Transformer BK-2500
Schneider Contactor LC1-D1201Q7N
CHINT Fuse RT29-125 80A
Pizzato Relay CS AT-02M230
EBG Resistor UXP-350-450KR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COTO Relay 3502-05-511
Panasonic Servo Motor MGME202GCG
TADIRAN Battery SL360-T
EATON VFD Frequency Converter MMX34AA9D0F0-0
Recent related posts
-
01/23/2024
Single Fan and Dual Fan for Household Central Air Conditioning Outdoor Unit: How to Choose?
Central air conditioning generally includes indoor units and outdoor units. For the selection of outdoor units, there are generally single fan and double fan types to choose from. So which one is better to choose?
-
09/07/2020
Reasons for rust or corrosion of gas tank
The gas storage tank is a part of the post-processing equipment of the air compressor, which mainly plays the role of gas storage, buffering, pressure reduction, and drainage. It will inevitably cause corrosion in the air, rain or humid atmosphere after long-term use or use for many years.
-
11/09/2021
PLC (Programmable Logic Controllers) and HMI (Human-Machine Interface) for Intelligent Factory
The development of "intelligent factory" has put forward a new direction for manufacturers. It is necessary for manufacturers to master the production and marketing process clearly
-
11/07/2021
The Era of Intelligent Building Management Comes with Siemens HMI + KNX
Siemens is a leading electronic and automation product manufacturer in the world. Based on its advanced human-computer communication technology and brand development concept
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
07/05/2020
Is Hitachi central air conditioning good okmarts.com tells you how powerful Hitachi compressors are
Is Hitachi central air conditioning good okmarts.com tells you how powerful Hitachi compressors are ? I saw many articles about Hitachi compressors, various parameters and terminology, and simply summarized the following points
-
09/09/2020
Comparison of screw type and piston type air compressor
Friends who are often exposed to air compressors should know the basic difference between piston air compressors and screw air compressors. They have obvious differences in structure, moving parts and operating parts, as well as consumption life and performance. , The following brings you some knowledge about the difference between the piston machine and the screw machine.
-
09/04/2020
The current situation and improvement measures of the compressed air dryer market
Compressed air dryers are mainly divided into adsorption dryers and refrigerated dryers. It covers a wide range of fields, mainly including metallurgy, petroleum, chemical, electric power, automobile manufacturing, food processing,
-
06/14/2020
Frequently asked questions about refrigeration compressors Do you know these?
1. Why control the impurity content and moisture content of the compressor and air conditioning system?
-
09/06/2023
What is an Inverter Heat Pump: Understanding the Technology and Benefits
An inverter heat pump is a type of HVAC system that uses advanced technology to provide efficient heating and cooling for residential and commercial spaces. Unlike traditional HVAC systems, which operate at a fixed speed, inverter heat pumps can vary their output to match the exact requirements of your space.