| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 0.4 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 0.28...0.4 A |
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.28...0.4 A N-release 5.2 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5?W
at AC in hot operating state per pole 1.8?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.28?...?0.4?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 0.4?A
operating current
at AC-3
at 400 V rated value 0.4?A
operating power
at AC-3
at 230 V rated value 60?W
at 400 V rated value 90?W
at 500 V rated value 120?W
at 690 V rated value 180?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 5.2?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 0.4?A
at 600 V rated value 0.4?A
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Ask questions
(0/1,200)
- Q: Can I request a specific delivery date for my order?
A: While we strive to deliver orders promptly, specific delivery date requests may not always be possible due to logistics and carrier limitations. However, if you have a specific requirement or need expedited shipping, please contact our customer service, and we will do our best to assist you.
- Q: What should I do if I forgot my password?
A: If you forgot your password, click on the "Forgot Password" link on the login page. Follow the instructions to reset your password.
- Q: Do you offer free shipping?
A: We may offer free shipping on select products or as part of promotional campaigns. You can check the product details or promotions to see if free shipping is available.
Reviews
- L
LYNETTE KILCOIN
Apr 12, 2025
Siemens Circuit Breaker 3RV2111-0EA10I'm really enjoying the quality of this product.HelpfulUnhelpful - F
Felipe Chaves
Jan 18, 2025
Siemens Circuit Breaker 3RV2111-0EA10Super response and quick deliveryHelpfulUnhelpful - J
Jay D. Maechtlen
Nov 09, 2024
Siemens Circuit Breaker 3RV2111-0EA10Had what I needed in stock.HelpfulUnhelpful - B
Bill Whitehurst
Oct 02, 2024
Siemens Circuit Breaker 3RV2111-0EA10Ideal destination for HVAC system repair and maintenanceHelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2111-0EA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2111-0EA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
GE Circuit Breaker MC0C310AT
Siemens Circuit Breaker 5SN4463-7CN
Siemens Circuit Breaker 3WT8040-7UG00-0AA1
Siemens Circuit Breaker 3WT8100-8UG04-5AB1
Siemens Circuit Breaker 5SY7201-7CC
Siemens Circuit Breaker 5SY6602-7CC
EATON Transformer STI0,06(230-230)
TENGEN Contactor TGCH1N-2011 AC110V
CITEL Surge Protection Device DS44S-480
Littelfuse Fuse 157.5701.6201
CRYDOM Relay A53TP100D
UniOhm Resistor 1206W4F1203T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Sanyo Denki Servo Motor GAM1A6040F0CNK1
AirTAC Air Cylinder TCM63X90
KITZ Ball Valve 10STR4LAF DN80
Contrinex Sensor BD1.5-W3-M8S
Copeland Compressor CR14K6E-PFV-870WB
Copeland Compressor ZP61KCE-TF7-522
Bristol Compressor H70R943DBER