| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 1 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 0.7...1 A |
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.7...1 A N-release 13 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25?W
at AC in hot operating state per pole 2.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.7?...?1?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 1?A
operating current
at AC-3
at 400 V rated value 1?A
operating power
at AC-3
at 230 V rated value 180?W
at 400 V rated value 250?W
at 500 V rated value 370?W
at 690 V rated value 550?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 13?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 1?A
at 600 V rated value 1?A
yielded mechanical performance hp
for three-phase AC motor
at 575/600 V rated value 0.5?hp
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 500 V gL/gG 10 A
at 690 V gL/gG 10 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Ask questions
(0/1,200)
- Q: Can I change the size or color of an item after placing an order?
A: If you need to change the size or color of an item after placing an order, please contact our customer service team as soon as possible. We will assist you in modifying the order if it hasn't been processed for shipping.
- Q: How can I participate in promotions or giveaways organized by sellers?
A: We regularly hold promotional events and organize giveaways and gift activities. You can follow our official announcements, emails, or social media channels to get information on how to participate and the details of these activities.
- Q: How can I provide feedback or share my shopping experience with you?
A: We highly value your feedback and would like to hear about your shopping experience. You can contact our customer service or provide feedback through the "Screenshot Feedback" feature on our website. We welcome your opinions and suggestions as they help us improve our services and better serve our customers.
Reviews
- S
Sean Grady
Aug 12, 2025
Siemens Circuit Breaker 3RV2111-0JA10I'm extremely pleased with the product's durability.HelpfulUnhelpful - B
Brett Walker
Jul 07, 2025
Siemens Circuit Breaker 3RV2111-0JA10Your assistance was superb.HelpfulUnhelpful - B
BRIAN TRAXLER
Sep 07, 2024
Siemens Circuit Breaker 3RV2111-0JA10Fast delivery, thanks so much.HelpfulUnhelpful - J
Joseph Gonzales
Mar 10, 2024
Siemens Circuit Breaker 3RV2111-0JA10Pleasant and everything went smoothly~HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2111-0JA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2111-0JA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
GE Circuit Breaker SFKOG 1.6-2.5A
Siemens Circuit Breaker 3AH4305-8RE44-0ED2-Z
Siemens Circuit Breaker 3WN6461-0HV58-0AK1
Siemens Circuit Breaker HHED63B080
Siemens Circuit Breaker 5SU9336-1CN25
Siemens Circuit Breaker 5SY4625-8CC
ABB Circuit Breaker MS116-12
ABB Circuit Breaker MS116-4.0
TRIAD Transformer MD-2400-E
Schneider Contactor LC1D40CCDC
Conquer Fuse APA-A
TYCO Relay MGAC-5W
IRC Resistor 20220522 115.2K
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ASHUN Check Valve MPCDV-04B-05-10
Delixi Relay CDZ9L-54P AC380V
Procon Vane Pump 111A100F11AA250PSI
BANDO Belt STS S5M-1250-30
ROSS Solenoid Valve W7476A6331
SKF Bearing NJ 2206 ECP/C3
Copeland Compressor 4DA3-100E-TSK
VBI Bearing NJ2318
Neuma Solenoid Valve NVSC-3541M-A1-5L
UniOP HMI eTOP312