Resolution:2500 PPR
Voltage:5V +- 10% DC
Signal:1 Vpp
SIEMENS Encoder 6FX2001-3CC50
People who bought this item also viewed
Tamagawa Seiki Encoder TS5016N532
HENGSTLER Encoder RI41-O/360ER.11KB
Yaskawa Servo Drive SGDH-08AE-S-OY
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder ADN-25-25-I-P-A
Siemens Contactor 3RT2535-1AP00
3 water pump SMI8-4T 380V
Vickers Solenoid Valve DG18V-3-2AL-B-60
Recent related posts
-
09/20/2023
Geothermal vs Air Source Heat Pump: Which One is Right for You?
As the world becomes more conscious about the environment, finding ways to reduce carbon emissions has become a top priority. One of the ways to achieve this is by using renewable energy sources to heat our homes.
-
07/01/2020
How to adjust the capacity of refrigeration compressor
How to adjust the capacity of refrigeration compressor The capacity of the compressor is determined according to the maximum production of BOG in the storage tank. After the compressor is selected, its capacity is constant. If the amount of inhaled air is greater than the amount of BOG produced in the tank, the tank pressure will drop.
-
04/11/2022
What Does an Expansion Valve Do?
Expansion valve is an important part of refrigeration system, which is generally installed between liquid storage tank and evaporator.
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.
-
08/16/2020
What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency.
-
07/15/2020
ZP725KCE-TWD60 HP 50Hz air conditioner Emerson Copeland compressor
Today's editor will introduce the Emerson Copeland compressor ZP725KCE-TWD, which is suitable for R410A refrigerant at 50Hz single-phase electric air conditioning. The power given in the manual of Emerson Copeland Scroll Air Conditioner Compressor is 60 hp. Other technical parameters can be downloaded from our company's website for inquiries.
-
08/23/2020
Why does the cooler temperature drop slowly
1. The cold storage has a large loss of cold due to poor heat insulation or sealing performance. Poor thermal insulation performance is due to insufficient insulation thickness of pipes, warehouse insulation walls, etc.,
-
06/14/2020
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year
Is it necessary to install the fresh air system recommended during decoration Where are the people who have been eating ash for many years but are secretly happy this year Is it necessary for ordinary families to install fresh air system?
-
07/06/2022
What is a Proportional Valve
A proportional valve provides a change in output pressure or flow in the same ratio as the change in the input, for example if the input doubles then the output will also double.
-
11/09/2022
Comparisons between the Electronic Expansion Valve and the Capillary Tube
The electronic expansion valve (EEV) and the capillary tube (CT) are both commonly used throttling devices in the refrigeration and the air conditioning systems.