TAIE Temperature Controller FY800-702000T
People who bought this item also viewed
Carel Temperature Controller RITCUSRG02
Meas Transmitter M5156-00000W-250BG
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Aupo Fuse A7-5A-F
Becker Vacuum Pump U5100
Baldor Servo Motor BSM63N-275BA
Recent related posts
-
08/17/2020
What should I do if the compressor current of an industrial chiller is overloaded? okmarts.com editor has a coup!
The compressor current overload phenomenon of industrial chillers, cause analysis and solutions. The "overcurrent" here refers to the current overload of the chiller compressor.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/05/2020
PORTABLE AIR COMPRESSOR MARKET SWOT ANALYSIS BY GROWTH AND FORECAST FROM 2020-2026|STANLEY BLACK&DECKER,POWERMATE,CAMPBELL HAUSFELD,SENCO
DataIntelo report titled Global Centrifugal Air Compressor Market provides detailed information and overview about the key influential factors required to make well informed business decision. This is a latest report, covering the current COVID-19 impact on the market.
-
08/11/2020
The role of these parts in cold storage construction
Speaking of cold storage, we must all know that in the field of food in our daily life, it brings us not only convenience in life, but also health and safety. Everyone knows that any piece of equipment will need a lot of large and small parts,
-
06/28/2020
One article to understand what is a piston compressor
One article to understand what is a piston compressor Piston compressor is a compressor that relies on live cold reciprocating motion to pressurize gas and deliver gas. It belongs to positive displacement compressor, also known as "reciprocating piston compressor" or "reciprocating compressor".
-
06/14/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
The 120KW cold capacity air-cooled compressor mainly has three related systems: refrigerant circulation system, water circulation system and automatic electrical control system.
-
04/04/2023
AC Compressor Failure and Case Analysis
The compressor is the energy core of the air-conditioning refrigeration (heat) system. In the refrigeration system, it mainly plays the role of compressing the refrigerant and promoting the continuous circulation of the refrigeration oil.
-
06/20/2020
Working principle of air conditioner temperature controller
In the use of our home air conditioners, the most important function is to ensure that our indoor temperature is maintained at a relatively comfortable degree, and the air conditioner temperature controller is a tool to help us achieve this. What is the principle of controlling the temperature of our air conditioner by air conditioner? Today I will introduce some working principles and functions of air conditioner temperature controller for everyone to understand.
-
08/31/2020
How to achieve zero consumption of compressed air for drainage
This article discusses the working principle of the compressed air zero-consumption automatic steam trap, and gives the most marketable accessory installation sample structure, and the actual energy-saving effect achieved in the actual application of the enterprise.
-
09/21/2020
The history of industry
China is one of the first countries in the world to invent rolling bearings. According to archaeological relics and data, China’s oldest bearing with the prototype of a modern rolling bearing structure appeared in Xuejiaya Village, Yongji County, Shanxi Province from 221 to 207 BC (Qin Dynasty).