Series | AG Series |
Type | Reciprocating Compressors |
Application | CBP - Commercial Back Pressure |
BTU Capacity | 30000 |
Refrigerant | R-404A/R-407A/R-448A/R-449A/R-452A |
Voltage | 200-230v |
Frequency | 60hz |
Phase | 3Ph |
Tecumseh Compressor AGA9530ZXT
Product Description:
Type: Reciprocating Compressors
Application: CBP - Commercial Back Pressure
Refrigerant: R-404A/R-407A/R-448A/R-449A/R-452
Voltage/Frequency: 200-230V 3~ 60Hz 200-220V 3 ~ 50H
Version: N/A
Product Specifications
Performance:
|
Refrigeration Capacity |
Input Power |
(E)Efficiency |
EVAP TEMP |
Condition |
AMBIENT TEMP |
RETURN GAS |
LIQUID TEMP |
|||||
Condition |
Test Voltage |
(R) Btu/h |
(R) kcal/h |
(R)W |
(I) W |
(E) Btu/ Wh |
(E) kcal/ Wh |
W/W |
|||||
ARI ( R- 407A) |
230V 3~ 60HZ |
30273 |
7634 |
8872 |
4423 |
6.85 |
1.73 |
2.01 |
-6.7°C (20°F) |
49°C (120°F) |
35°C (95°F) |
4.4°C (40°F) |
49°C (120°F) |
ARI ( R- 448A) |
230V 3~ 60HZ |
30083 |
7586 |
8816 |
4530 |
6.64 |
1.67 |
1.95 |
-6.7°C (20°F) |
49°C (120°F) |
35°C (95°F) |
4.4°C (40°F) |
49°C (120°F) |
ARI ( R- 449A) |
230V 3~ 60HZ |
30083 |
7586 |
8816 |
4530 |
6.64 |
1.67 |
1.95 |
-6.7°C (20°F) |
49°C (120°F) |
35°C (95°F) |
4.4°C (40°F) |
49°C (120°F) |
ARI ( R- 452A) |
230V 3~ 60HZ |
26758 |
6747 |
7842 |
4812 |
5.56 |
1.4 |
1.63 |
-6.7°C (20°F) |
49°C (120°F) |
35°C (95°F) |
4.4°C (40°F) |
49°C (120°F) |
ARI ( R- 404A) |
230V 3~ 60HZ |
29500 |
7434 |
8644 |
5270 |
5.6 |
1.41 |
1.64 |
-6.7°C (20°F) |
49°C (120°F) |
35°C (95°F) |
4.4°C (40°F) |
49°C (120°F) |
General
Evaporating Temp. Range: -17.8°C to 10°C (0°Fto 50°F)
Motor Torque: High Start Torque (HST)
Compressor Cooling: Fan
Mechanical
Weight: 105
Weight Unit of Measure: LB
Displacement (cc): 112.422
Oil Type: Polyolester
Viscosity(cSt): 32
Oil Charge (cc): 1955
Electrical
Voltage Range (50 Hz): 180-242
Voltage Range (60 Hz): 180-254
Locked Rotor Amps (LRA): 126
Tecumseh Compressor AGA9530ZXT
People who bought this item also viewed
Hitachi Compressor G402DHV-64A1
Bristol Compressor L64A113BBCA
Bristol Compressor L63B752BBKB
Copeland Compressor ZB76K5E-TFC-260
Tecumseh Compressor AE4450Z-FZ1A
Tecumseh Compressor AE4430YS
Tecumseh Compressor AEA4440AXA
Tecumseh Compressor CAE4456Y
LG Compressor QJ208HMA
GMCC Compressor PH371X3CS-4MU1
KONOR Compressor GQY99AA
Copeland Compressor ZB21KQE-TFD-558
CHINT Transformer NDKS-400
Danfoss Expansion Valve 067N3168
ALBRIGHT Contactor SW180B-751
JAMICON Fan JF1238B2UR-R
TCG Electric Motor TCV18-200-(3-10)S
Bosch Filter 0986AF3386
Danfoss Sight Glass SGP16SN
Samsung Expansion Valve Coil LGK-04
MURATA Capacitor RPE113X7R105M50
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TCS Oil Seal TC 18*30*10
BANDO Belt T2.5-950-10
ACTEL IC A42MX16-PQG100I
VISHAY Capacitor 300V 0.001UF
AirTAC Air Cylinder SCD200X250S
Recent related posts
-
06/21/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
08/23/2020
Operation flow chart of cold chain cold storage management system
In recent years, people's demand for fresh food has increased, which has promoted the development of the cold storage industry, and has also brought many problems and challenges.
-
10/23/2023
Air Conditioner Line Frozen: Causes, Troubleshooting and Prevention Methods
When the air conditioner line freezes, it can be a frustrating experience for homeowners. Not only does it disrupt the cooling process, but it also indicates an underlying issue that needs to be addressed.
-
09/22/2020
Discussion on the Causes of Rotor Scaling of Natural Gas Compressor
An oilfield company’s compressor station ammonia compression refrigeration device mainly caused the reduction of natural gas processing capacity and increased power consumption; severe fouling would cause
-
08/19/2020
Three maintenance and inspection methods for air-conditioning refrigeration compressors
In order to ensure the normal operation of the compressor and prolong its service life, in addition to regular maintenance and inspection, daily maintenance and inspection are very important.
-
08/17/2020
Why can't the cold storage temperature drop The evaporator is very important!
There are many reasons why the temperature of the cold storage cannot drop. The editor of okmarts.com lists the following six common phenomena for your reference:
-
03/01/2024
A Guide to Fresh Air Ventilation System: Working Principle, Functions & Types
Fresh air ventilation system, also known as "house breathing system", is a type of indoor exhausting and ventilation system. It can discharge the dirty indoor air to the outside while also pulling fresh outdoor air into the room.
-
06/14/2020
Refrigeration compressors have five major technological
Refrigeration compressors have five major technological developments around energy saving CFCs and HCFCs refrigerants that have a destructive effect on the ozone layer are phase-out substances specified in the Montreal Protocol
-
06/14/2020
The harm and elimination method of air intake in refrigeration system
The harm and elimination method of air intake in refrigeration system 1 Overview In the refrigeration system, the so-called non-condensable gas means that when the refrigeration system is working, at a specific temperature and pressure in the condense 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ӡ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
03/20/2023
Structural Characteristics of Vacuum Pump
The vacuum pump refers to a device or equipment that uses mechanical, physical, chemical or physical-chemical methods to extract air from the pumped container to obtain a vacuum.