Long service life, long-term maintenance-free operation
Low dust generation, low noise,acceptable running sound
Smooth motion in all mounting orientations
Thin, compact design, large radial load capacity
Superb in planar running accuracy
Superb capability of absorbing mounting error
THK Linear Guideway SRS12WM
People who bought this item also viewed
THK Linear Guideway SHS25LV1UU
THK Linear Guideway SHS30LR1SS
THK Linear Guideway SHS20LV1SS
THK Linear Guideway HSR35LB1UU
SBC Linear Guideway SBG20FL-C-K1
HIWIN Linear Guideway HGH15CAH
HIWIN Linear Guideway HGW35HCC
DEK Printing Machine Parts 185281
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
COSEL Power Supply PBA1500F-5-C
Bristol Compressor L64A183DBL
TCH Vane Pump PVF23-116-F-R
Panasonic Servo Motor MGMF442L1G6M
DHF Tool for Metal Cutting UTW0603
Recent related posts
-
09/10/2020
Air compressor lubricant performance requirements
1. High quality base oil The base oil of compressor oil can be divided into two categories: mineral oil type and synthetic oil type. The production of mineral oil-type compressor oil is generally obtained by solvent refining, solvent dewaxing, hydrogenation or clay supplement refining to obtain the base oil, and then add a variety of additives to blend.
-
08/03/2020
What is the cooling system of the computer room refrigeration facility, adsorption refrigeration, and assembly cold storage
Many people have little understanding of the cooling system of the computer room refrigeration facility, adsorption refrigeration, and prefabricated cold storage.
-
08/14/2020
How does the cold storage refrigeration system supplement and discharge refrigerant
The cold storage refrigeration system must ensure that the refrigerant is dry when adding refrigerant (only applicable to fluorine refrigerant refrigeration systems),
-
08/16/2020
What is the difference between a water source heat pump and a water ring heat pump
1. Water source heat pump technology Water source heat pump technology is a low-temperature low-level thermal energy resource formed by using solar energy and geothermal energy absorbed from shallow water sources on the earth's surface
-
06/24/2020
What's wrong with the freezer not cooling
There are four main reasons: the first is the lack of refrigerant and the compressor has problems; the second is the problem of the power cord of the freezer; the third is the frost in the evaporator of the freezer; the fourth is that the storage in the freezer is too full. Of course, no matter what the reason is, you should find a professional to help repair the loophole or add refrigerant.
-
09/08/2020
Air compressor lubricant model the difference between No. 32 and No. 46 air compressor lubricants
Air compressor lubricants are generally No. 32 oil and No. 46 oil. No. 32 is a mineral type. The general service life is about 2000 hours and needs to be replaced. The operating temperature must be below 90 degrees to avoid carbon deposits.
-
06/30/2020
Causes of compressor burnout
Causes of compressor burnout Common failures of compressors are mainly the following three: 1. Motor burned out; 2. Liquid shock; 3. Oil shortage caused by refrigeration oil. Today I will give you a detailed analysis of the cause of the motor burnout.
-
06/14/2020
Capillary
The capillary tube is the simplest throttling device. The capillary tube is a very thin diameter red copper tube with a specified length. Its inner diameter is generally 0.5 to 2 mm. Characteristics of capillary tube as throttling device
-
07/03/2022
What is a Magnet Pump?
Magnet pumps are seal-less pumps that use the technology of a drive magnet and inner magnet connected to an impeller to move fluid through the pump.
-
12/13/2023
R410a VS R134a: Comparison of Commonly Used Refrigerants in Data Centers
At present, data centers mainly use two types of refrigerants. One is R410a, which is mainly used in small or medium-sized data centers with air conditioning cooling capacity of 300-400 KW.