Togami Contactor PAK-19J
Togami Contactor PAK-19J
People who bought this item also viewed
Togami Contactor PAK-21J
Togami Contactor PAK-35U
Togami Contactor CLK-15J40-S642C
Togami Contactor PAK-35J
Togami Contactor CLK-15J20-P6C
HITACHI Contactor X8-GWE
Fuji Contactor SL25-H22
Fuji Contactor SC-E2SP-G
Block Transformer VB3.2/2/24
SQUARE D Circuit Breaker MGA36450
Littelfuse Fuse FLNR-8
TYCO Relay VF7-11F11
IRC Resistor RNC65H2053FM
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Delta Fan ASB0205LA-00CFJ
Balluff Sensor BFO0055
KOGANEI Air Cylinder SDA25X15-N-180
YI-SHING Vane Pump PV2R12-53-28-FR
Leynow Vacuum Pump LV0202
Recent related posts
-
02/27/2021
Working principle of servo motor (how servo motor works)
The rotor inside the servo motor is a permanent magnet. The U / V / W three-phase electricity controlled by the driver forms an electromagnetic field. The rotor rotates under the effect of this magnetic field. At the same time, the encoder of the motor feeds back the signal to the driver. The driver adjusts the rotation angle of the rotor according to the comparison between the feedback value and the target value. The accuracy of servo motor depends on the accuracy of encoder (number of lines).
-
09/03/2020
Introduction of simple pressure vessel and fixed pressure vessel for air compressor gas storage tank
As the fourth most widely used energy source, compressed air is second only to traditional energy sources such as electric energy. As a necessary product for air compressors, compressed air is widely used in various fields of national production and life in my country.
-
06/29/2020
Compressor protection measures against liquid strikes
Compressor protection measures against liquid strikes When too much liquid enters the cylinder and it is too late to discharge it from the exhaust valve, a liquid blow will occur in the cylinder. The high pressure generated during the liquid blow damages the cylinder, piston, connecting rod, etc., so it is necessary to take a Series of protective measures.
-
08/20/2020
Cold storage anti-corrosion and anti-frost coatings effectively solve the problem of frosting and corrosion
In the cold storage, when the dew point of the air is lowered by the cooling pipe surface, the moisture in the food and air will precipitate and condense on the pipe wall. If the pipe wall temperature is lower than 0°C, it will condense into a rain layer.
-
09/01/2022
The Working Principle of the Vacuum Contactor
The vacuum contactor uses the vacuum interrupter to extinguish the arc to frequently connect and cut off the normal working current.
-
04/29/2022
How to test a contactor?
Check the rated voltage of the contactor coil and connect it to the matching power supply. Open the switch and check whether the contactor is closed. If it cannot be pulled in, it indicates that the contactor coil is faulty.
-
08/15/2020
Precautions during the use of air-cooled refrigerators
Before using the air-cooled chiller, you can carefully count the operating data of the equipment, and then based on these operating data, you can make a basic judgment on the operating status of the equipment,
-
07/31/2020
What are the specific operation methods for maintenance of screw compressors in cold storage
Before the cold storage screw compressor must be overhauled, if possible, unload the slide valve to the "0" position, shut down normally, and cut off the power supply.
-
06/25/2020
Classification of air-conditioning compressors
The air-conditioning compressor plays the role of compressing and driving the refrigerant in the air-conditioning refrigerant circuit. The working circuit is divided into an evaporation area (low pressure area) and a condensation area (high pressure area). The indoor unit and outdoor unit belong to the high-pressure or low-pressure area (depending on the working state), and the compressor is generally installed in the outdoor unit.
-
09/11/2020
Summary Essentials of water treatment for central air-conditioning chillers
Looking at the management of central air-conditioning throughout the country, it is found that very few are well managed, and all have problems of one kind or another to varying degrees. The main problems are described as follows: 1. Problems caused by the unreasonable design of the design department