Revolutions:4096
Interface:PROFIBUS DP
Pinout:TR-ECE-TI-DGB-0112
Supply voltage:11-27V
TR Encoder CMV58M-00023
People who bought this item also viewed
Mitsubishi Servo Motor HF-SN302BJ
Allen Bradley Servo Drive 2099-BM09-S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KCL Vane Pump VQ435-216-88-F-RARA-02
SMC Solenoid Valve SY5320-5GD-01
Yaskawa Servo Motor SGMG-13ASR-ES12
FITOK Ball Valve BGSS-ML20-15
ZIPPY Power Supply DR2Z-6400F-R
PTC Industrial Heater 175 2200w
Recent related posts
-
08/12/2020
How to choose the expansion valve of air-cooled chiller How to judge high and low pressure
How to choose and install the expansion valve for industrial chillers, screw chillers, air-cooled chillers, and chillers: The choice of expansion valve and the performance of the air-cooled chiller refrigeration system play an important role, the correct ¨ﰨ2
-
02/20/2024
Electric Furnace vs. Gas Furnace: Working Principle, Pros & Cons, Factors to Consider
As winter approaches and the need for a reliable heating system becomes paramount, the choice between an electric furnace and a gas furnace is a decision many homeowners must grapple with.
-
01/08/2021
The relationship between the start of the compressor with liquid and the migration of refrigerant and the solution
The relationship between the start of the compressor with liquid and the migration of refrigerant and the solution One, start with liquid First, let's define what is called liquid start. When the refrigeration unit is in the shutdown state, there is ref 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ҡ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴
-
06/29/2020
What are the causes treatment and prevention methods of compressor liquid blow
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows:
-
11/30/2021
Differences Between Sensor and Transmitter
Sensors and transmitters play an important role in the field of automatic control. Transmitters are developed based on sensors, which have close relationship and differences.
-
07/28/2020
Method and steps to replace the refrigeration compressor
Cut off the power supply: Before replacing the compressor, be sure to cut off the power supply of the unit, otherwise there will be a risk of electric shock.
-
03/02/2021
Connection between Arduino and servo motor
The connection of the servo motor using Arduino is as follows: Connect the black wires on the two servo motors to the GND on the Arduino Connect the red wires on the two servo motors to the 5V pin on the Arduino Connect the yellow wire on the first motor to pin 8 on the Arduino
-
07/14/2020
I realized that in winter, the refrigerator should be adjusted correctly, and the power saving and cooling are correct.
I realized that in winter, the refrigerator should be adjusted correctly, and the power saving and cooling are correct. I believe that there should be a refrigerator in the home of the friends, the role of the refrigerator is to freeze and refrigerate the food in the home.
-
05/10/2023
What is a scroll compressor? Everything You Need to Know
A scroll compressor (also called spiral compressor, scroll pump and scroll vacuum pump) is a device for compressing air or refrigerant. So there are scroll air compressors and scroll refrigeration compressor (refrigeration scroll compressor).
-
06/20/2020
Installation instructions for explosion-proof air conditioners
Installation instructions for explosion-proof air conditioners <img src="{{media url="Installation_instructions_for_explosion-proof_air_conditioners.jpg"}}" alt="" /> 1. The power supply of the explosion-proof air conditioner shall have a dedicated line, and a circuit breaker or air switch shall be provided in the dedicated line. The power supply wires and fuses should comply with the relevant regulations and cannot be changed at will.