Primary Voltage:115 V/230 V
Secondary Voltage in Series:36 V CT at 4.44 AA
Secondary Voltage in Parallel:18 V at 8.88 A
Primary Frequency:50 Hz/60 Hz
TRIAD Transformer VPT36-4440
People who bought this item also viewed
Siemens Transformer Y55-0135
CHINT Transformer JMB-3000
Shihlin Circuit Breaker BW-2000S 3P 1600A
Hager Contactor ETC363P
Littelfuse Fuse KLKR15
ABB Relay TA25DU-14M 10-14A
Yageo Resistor FKN3WSJR-73-4R7
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BOSCH Flowmeter 0280218190 LM0036
Hitachi Compressor E405DHD-42A2YG
Schneider Sensor XS4P18NC410
Ferraz Shawmut Fuse A15QS80-4
Recent related posts
-
08/12/2020
Selection and Selection of Operation Mode of Ice Storage Process in Ice Storage Air Conditioning Ice storage process selection:
During the operation of the ice storage air conditioning system, the refrigerator can have two operating conditions, namely, ice storage conditions and cooling conditions.
-
01/09/2021
Be sure to understand these before installing a new fan
The most troublesome thing: the new fan requires indoor and outdoor air exchange, which requires opening holes on the wall or glass. The diameter of the holes in the market is basically concentrated on 150mm\120mm\110mm\100mm.
-
04/25/2023
What are the 4 Main Components in a Central AC System
There are four main components in the central air conditioning system, namely: compressor, condenser, throttling device, and evaporator. Evaporators and condensers are collectively referred to as heat exchangers
-
07/31/2020
How to use refrigerant to empty the air conditioner after installation
Air, moisture and impurities contained in the air will cause pressure increase, current increase, noise increase, and power consumption increase in the air conditioner system, which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage.
-
09/07/2022
What is Three Phase Induction Motor and How Does It Work
Three-phase induction motor is an AC motor that generates electromagnetic torque to drive the rotor to rotate by the interaction of the rotating magnetic field formed by the stator winding
-
06/13/2020
How much future does using water as refrigerant
How much future does using water as refrigerant Refrigeration technology is always developing in the direction of high efficiency and environmental protection, but is it very futuristic to use water as a refrigerant?
-
09/23/2020
Automatic control scheme for multiple adsorption dryers and air compressors
With the development of modern industry and the improvement of automation level, various industries have higher and higher requirements for air supply, purification level, automatic control, and continuous and reliable air supply of air compressor stations.
-
07/16/2020
ZB scroll compressor configuration
ZB scroll compressor configuration Compressor model; built-in pressure relief valve; exhaust temperature protection; exhaust check valve; motor protector; midpoint protector ZB15-ZB48; ZF09-ZF18; IPR; TOD has a midpoint protector ZB58-ZB114; None; ASTP has key protectors Built-in pressure relief valve (IPR valve)
-
03/02/2021
Control mode of servo motor
Torque control: the torque control mode is to set the external output torque of the motor shaft through the input of external analog quantity or the assignment of direct address. For example, if 10V corresponds to 5nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5nm: if the load of the motor shaft is lower than 2.5nm, the motor will rotate forward, and when the external load is equal to 2.5nm
-
03/12/2024
EC Fan: Everything You Need to Know
In the realm of modern ventilation and air circulation systems, Electronically Commutated (EC) fans have emerged as a groundbreaking technology.