07/05/2022
Installation Of Magnet Pump
1.Dropping or subjecting the pump to strong impact may result failure. Handle the pump with care.
-
07/20/2022
Common Faults and Solutions of Diaphragm Pump
During the operation of the diaphragm pump, there should be no abnormal sound, and all parts should be free of running, emitting, dripping, leakage and other phenomena.
-
05/09/2023
What is Refrigeration Cycle? The Refrigeration Cycle Explained
The refrigeration cycle is a cyclic process in which heat is transferred from a low-temperature object (or environment) to a high-temperature object (or environment) through a refrigerant, thereby cooling the object to a temperature lower than the environment and maintaining this low temperature.
-
06/13/2020
What does the air conditioning cooling capacity mean
In addition to the different size of the air conditioner, the important indicator is the cooling capacity. The cooling capacity refers to the total amount of heat removed from the confined space, room or area per unit time when the air conditioner is perf 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
09/14/2020
The exhaust temperature of the unit is high (over 100℃)
The lubricating oil level of the unit is too low (the green position should be visible from the oil level mirror);
-
07/18/2020
reasons why the constant temperature and humidity test chamber does not cool
1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil damage the suction valve plate when the gas is sucked into the cylinder of the compressor, and it is produced when the piston is compressed when the piston is close to the top dead center and is not quickly discharged during the exhaust process after entering the cylinder.
-
07/21/2020
How to protect the refrigeration compressor, you must master the following knowledge!
When the compressor is running, some abnormal conditions may occur, such as: exhaust pressure is too high, suction pressure is too low, oil pressure is insufficient, motor is overheated, excess liquid enters the cylinder, etc. In the event of an abnormal situation, the compressor will be damaged if there is no protective measure.
-
08/11/2020
The relationship between refrigerant and water in explosion-proof chemical air conditioning
Compared with ordinary air conditioners, the good explosion-proof performance of explosion-proof chemical air conditioners is an important factor in the selection of enterprises.
-
06/13/2020
Single screw compressor
Single screw compressor
-
01/07/2024
Cooling Tower: Components, Working Principle, Types, Applications, and Precautions
A cooling tower is a device that uses the contact between water and air through the process of evaporation to dissipate waste heat generated in industrial or air conditioning systems.