Vargus Tool for Metal Cutting 2ER 0.35ISO VTX
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-O/2048EK.42KJ
TSUBAKI Belt BG852P3M10-530
Recent related posts
-
07/08/2022
Installation and Adjustment of Proportional Valves in Your Car
The proportional valve is mounted between the brake line master cylinder and the rear wheels. It's designed to adjust the pressure between the front and rear brakes, depending on how hard you're stopping.
-
09/15/2020
The technical status and development trend of air compressor
I. Introduction Compressor is a machine used to increase gas pressure and transport gas, and belongs to a working machine that converts the power energy of the prime mover into gas pressure energy. It has a wide range of types and uses, and is known as "general machinery".
-
03/14/2021
Function of servo drive
Regeneration and dynamic braking function; Instant power down protection function for quick shutdown;
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.
-
02/27/2021
Some common faults and solutions of servo motors
The temperature of the motor is too high or the motor is faulty with smoke the reason: 1). Excessive load 2). Two-phase operation
-
01/10/2023
5 Refrigeration Solenoid Valve Failures and the Solutions
Refrigeration solenoid valve is an industrial equipment controlled by solenoid. It adjusts mass direction, flow, speed and other parameters in industrial control systems.
-
06/21/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />
-
08/16/2020
The difference between condenser and cooler
There will be compressors, condensers, evaporators, expansion valves and refrigerants in the chiller refrigeration system. Only with the addition of these original parts will a good refrigeration system be formed.
-
12/22/2021
How to Calibrate a Pressure Transmitter Before Use
Pressure transmitter is a kind of commonly used measuring instrument, which can convert the physical parameters such as gas and liquid sensed by load cell into standard signal output.
-
09/16/2020
Check Valve PrincipleCheck Valve StandardCheck Valve Features
Check Valve Principle|Check Valve Standard|Check Valve Features|Check Valve Function|Check Valve Size Check valve is also called one-way valve or check valve, its function is to prevent the medium in the pipeline from flowing back. The bottom valve of the pump to close the water is also a check valve.