Rotation CCW or CW
Mounting Flange SAE 2 Bolt B
Maximum Continuous†
Pressure 248 bar [3600 PSI]*
Maximum Intermittent†† Pressure 276 bar [4000 PSI]**
Minimum Speed at Continuous Pressure 750 RPM
Maximum Continuous Inlet Temperature 107°C [225°F]
Minimum Operating Temperature -29°C [-20°F]
Maximum Inlet Vacuum at 82°C [180°F] and Rated Speed 6.0 In. Hg
vickers Gear Pump 26002-RZA
People who bought this item also viewed
Sumitomo Gear Pump QT43-25-A
KITZ Check Valve PN16FWNBUE-DN250
Nachi Overflow Valve ORO-G03-B3-J50
Daikin Piston Pump VZ50C34RJPX-10
KCL Vane Pump VQ225-52-22-F-RARA-02
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
06/20/2020
Working principle of reciprocating compressor_Working process of reciprocating compressor
Working principle of reciprocating compressor<img src="{{media url="Working_principle_of_reciprocating_compressor.jpg"}}" alt="" />_Working process of reciprocating compressor Working principle of reciprocating compressor Relies on periodic changes in the working volume of the cylinder to compress the gas to achieve the purpose of increasing the working pressure. (The reciprocating movement of the piston in the cylinder causes the decompression to suck the gas, and then compress the gas to a certain pressure and send it out.) The working principle of the piston compressor.
-
07/07/2020
Quick look Small chillers summer maintenance tips
Quick look! Small chillers summer maintenance tips The high-temperature summer is a frequent season of safety production accidents, which affects the cooling effect of small chillers to a certain extent. Therefore, in order to reduce the equipment failure time and the losses it brings, we must always pay attention to the impact of high temperature on the small chiller equipment, and do a good job in the summer maintenance of the small chiller.
-
06/27/2020
The working principle and characteristics of inverter compressor
Inverter compressor refers to a compressor whose relative speed is constant, and whose speed is continuously adjusted within a certain range through a control method or means, which can continuously change the output energy.
-
01/22/2024
Single Fan and Dual Fan for Household Central Air Conditioning Outdoor Unit: How to Choose?
Central air conditioning generally includes indoor units and outdoor units. For the selection of outdoor units, there are generally single fan and double fan types to choose from. So which one is better to choose?
-
01/31/2023
What is Gear Ratio?
Gear ratio, i.e., the reduction ratio of the reducer, refers to the ratio of the instantaneous input speed to the output speed in the reduction mechanism, and is represented by the symbol "i".
-
02/23/2021
What to do if Haier refrigerator doesn't cool
In the process of using home appliances, there will be some situations. I believe many people have encountered that the refrigerator at home is not cooling. What will you do when you encounter this situation? Let’s take a look at Haier with the editor. What to do if the refrigerator is not cooling, for your reference.
-
10/18/2023
Dehumidifier Compressor Hot: Reasons and Fixes
A dehumidifier is an essential appliance for maintaining a comfortable and healthy indoor environment by reducing excessive humidity.
-
04/25/2024
Rexroth Servo Drive Fault Codes and Troubleshooting Methods
Common faults of Rexroth servo drives / servo controllers include: no display, phase loss, overcurrent, overvoltage, undervoltage, overheating, overload, grounding, parameter errors, display but no output, module damage, etc.
-
08/09/2020
DORIN compressor
DORIN Compressor Co., Ltd. of Italy was established in 1918. It is one of the founding organizations of ASERCOM in Europe and one of the few top refrigeration compressor manufacturers in the world.
-
06/25/2020
Basic knowledge of air energy
At present, the most commonly used vapor compression heat pumps, compressors, evaporators, condensers, and throttle valves are the four main components. Other auxiliary components include fans, four-way valves, liquid storage tanks, gas-liquid separators, copper pipes, and Protectors and electronic control parts used to ensure the normal operation of the machine, etc. Direct-heating models also include a water flow regulating valve. Schematic diagram of commercial air source heat pump system