WECON HMI LEVI102EL
People who bought this item also viewed
Mitsubishi HMI A975GOT-TBD-CH
Weintek HMI MT506MV5WV
Fuji HMI Industrial Touch Screen V710SD
Weintek HMI MT8050iE
Mitsubishi Servo Motor HF54BT-A48
TECO Servo Drive TSTE20C
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron HMI NT2S-SF121B-EV2
Fuji Contactor SC-N2S-G
Recent related posts
-
06/13/2020
Precautions for the operation of cold storage equipment
Precautions for the operation of cold storage equipment 1. For the evaporator of the air-cooled machine: always check the defrosting situation, whether the defrosting is timely and effective, it will affect the cooling effect and cause the liquid return 器2 䀀 ᅵ皥
-
06/13/2020
Rotor compressor
The rotor compressor is driven by the engine or the motor (mostly driven by the motor), and the other rotor (also known as the female rotor or the concave rotor) is driven by the oil film formed by the main rotor through oil injection, or by the main roto 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然
-
06/13/2020
Screw refrigeration compressors are prone to these types of failures, have you ever encountered them
1. Fault type 1. Abnormal compression ratio 2. Low condenser efficiency and failure 3. Low evaporator efficiency and failure 4. Failure of the oil system 5.Electrical failure
-
06/29/2020
Treatment of frost in crankcase when compressor head frost is serious
Treatment of frost in crankcase when compressor head frost is serious The frost on the cylinder head is caused by a large amount of wet steam or refrigerant sucked into the compressor. The main reasons for this situation are:
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.
-
06/13/2020
How important is the installation environment of the refrigeration unit It is enough to do these 4 points!
How important is the installation environment of the refrigeration unit It is enough to do these 4 points! The refrigeration equipment (compressor unit) is installed in the machine room, and the surrounding environment should be maintained:
-
07/09/2020
Global Scroll Compressors Market 2020 Industry Segment – Air Squared, LG, Airpol, Bitzer, BOGE
Recently MarketsandResearch.biz has published a new report entitled Global Scroll Compressors Market Growth 2020-2025 goes into the past for analyzing the market scenario, at the same time, it provides a complete insight into the market. Starting from the number of sales made, the price structure of each segment, revenue generated and expected to be made,
-
08/15/2020
The main cause of cold storage fire is cold storage installation or cold storage construction
In recent years, we have seen a lot of news about cold storage fires. Once a cold storage causes a fire, it will not only cause economic losses to us, but also may cause safety problems.
-
06/29/2020
How to deal with compressor stuck cylinder
How to deal with compressor stuck cylinder The compressor jamming cylinder means that the shaft of the compressor is stuck, and the compressor cannot rotate at this time. The cause of the compressor jamming cylinder is either the lack of refrigeration oil, insufficient lubrication and increased friction, or the presence of dust or impurities in the pipeline, which causes the moving surface to be stuck, or the pure mechanical failure causes the compressor to be stuck.
-
08/11/2020
Common practice of oil return design in refrigeration system
When the condenser is installed higher than the compressor, a U-shaped bend is required at the intake pipe of the condenser to prevent oil from returning to the exhaust side of the compressor during shutdown and also help prevent liquid refrigerant from the condenser