Global one-stop procurement platform for industrial spare parts.
support01@okmarts.com service@okmarts.com hydraulic@okmarts.com
Okmarts.com Online Store, Refrigeration Compressor Price, O&Kmarts Logo
Max 200 characters
Display the website inEN
EN
translate to EN
EN
translate to ES
ES
translate to العربية
العربية
All
ASSOMA
ASSOMA
  • Magnet Pump
    Magnet Pump
DATTO
DATTO
  • Magnet Pump
    Magnet Pump
Iwaki
Iwaki
  • Magnet Pump
    Magnet Pump
  • Diaphragm Pump
    Diaphragm Pump
PAN WORLD
PAN WORLD
  • Magnet Pump
    Magnet Pump
Colrey
Colrey
  • Magnet Pump
    Magnet Pump
CTMP
CTMP
  • Magnet Pump
    Magnet Pump
All Brands
All Brands
    • a
    • b
    • c
    • d
    • e
    • f
    • g
    • h
    • i
    • j
    • k
    • l
    • m
    • n
    • o
    • p
    • q
    • r
    • s
    • t
    • u
    • v
    • w
    • x
    • y
    • z
    • 3
    • 7
      Top Picks
      • WILO Magnet Pump PM-250PE
      1/1
      WILO Magnet Pump PM-250PE
      $ 720 .00

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      • Specifications
      • Q&A
      • Reviews
      The WILO Magnet Pump is high quality!
      Power source: 1-220V/50Hz
      Input/Output power: 350/250 W
      Approved fluids: chemical liquid
      Max. head: 6 m
      Maximum flow: 100 L/min
      Rated flow: 50 L/min
      Maximum pressure: 6 bar

      Ask questions

      (0/1,200)

      Max 1200 characters

      • Q: Are there shopping protection plans or extended warranty services?

        A: Depending on the category and brand of the product, we may offer shopping protection plans or extended warranty services. You can view relevant information on the product details page and choose to purchase based on your needs.

      • Q: Are the actual colors of the products consistent with the pictures?

        A: We do our best to ensure the accuracy of product images. However, due to variations in display devices and lighting conditions, there may be slight differences in actual colors. We provide detailed color descriptions to assist you in making better choices.

      • Q: How can I change my email address associated with my account?

        A: To change the email address associated with your account, please contact our customer service team and provide them with the necessary verification information. They will assist you in updating your email address.

      View More
      Question has been sent successfully

      Reviews

      • M

        Michael Earley

        Jul 18, 2025

        WILO Magnet Pump PM-250PE
        Tiene las piezas que necesito y envía muy rápido
        Helpful
        Unhelpful
      • D

        Donald Wood

        May 08, 2025

        WILO Magnet Pump PM-250PE
        You can easily find the information you need.
        Helpful
        Unhelpful
      • M

        Michael Nichols

        May 04, 2024

        WILO Magnet Pump PM-250PE
        The product arrived on schedule, and it's perfect.
        Helpful
        Unhelpful
      • G

        Gregory Colt

        Oct 21, 2023

        WILO Magnet Pump PM-250PE
        It came quickly and I'm really happy with it.
        Helpful
        Unhelpful
      • A

        Anonymous user

        Nov 25, 2022

        WILO Magnet Pump PM-250PE
        All was ok! No problems whatsoever.
        Helpful
        Unhelpful

      WILO Magnet Pump PM-250PE

      $ 720 .00
      Click here to view shipping costs.

      ✔ In Stock (Can ship in 5-7 days)

      Quantity
      MOQ : 1
      Payment Methods
      T/T pay VISA pay mastercard pay Diners Club pay Discover pay JCB pay American Express pay Stripe pay PayPal pay Google pay Apple pay Link pay venmo pay
      • Online Support 24/7

      • 12 Months Warranty for New Products

      • 30 Days Money Back Guarantee

      People who bought this item also viewed

      New In stock for sale, Iwaki Magnet Pump MX-251CV5-4

      Iwaki Magnet Pump MX-251CV5-4

      US$2936.75
      New In stock for sale, Iwaki Magnet Pump MD-100FY-3

      Iwaki Magnet Pump MD-100FY-3

      US$1018.53
      New In stock for sale, VACUTRONICS Vacuum Pump JP-180V

      VACUTRONICS Vacuum Pump JP-180V

      US$1561.54
      New In stock for sale, Iwaki Diaphragm Pump WEZC36D1VC

      Iwaki Diaphragm Pump WEZC36D1VC

      US$1049.95
      New In stock for sale, EMAUX Water Pump SR20 380V

      EMAUX Water Pump SR20 380V

      US$712.69
      New In stock for sale, Burgmann Mechanical Seal M37G/18-G6 (TC/SIC/VIT)

      Burgmann Mechanical Seal M37G/18-G6 (TC/SIC/VIT)

      US$34.62

      Customers frequently viewed

      New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

      IWAYA DENKI Water Pump 25CJT0752

      US$2307.69
      New In stock for sale, Panasonic Servo Motor MHMF022L1V2M

      Panasonic Servo Motor MHMF022L1V2M

      US$653.85
      New In stock for sale, Honeywell Solenoid Valve VE4025B1045

      Honeywell Solenoid Valve VE4025B1045

      US$334.62
      New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

      ROTEN Mechanical Seal 8E5K-22-X

      US$384.62
      New In stock for sale, SANDSUN Overload Pump VA08H-760

      SANDSUN Overload Pump VA08H-760

      US$1568.40
      New In stock for sale, GS Battery 6-QW-60(450)-(55D23L-KR)

      GS Battery 6-QW-60(450)-(55D23L-KR)

      US$646.15
      New In stock for sale, Rechi Compressor 44R273A

      Rechi Compressor 44R273A

      US$341.00
      New In stock for sale, Bosch Rexroth Linear Guideway Runner Block R165381920

      Bosch Rexroth Linear Guideway Runner Block R165381920

      US$107.69
      New In stock for sale, MINDMAN Air Cylinder MCQV2-11-40-200

      MINDMAN Air Cylinder MCQV2-11-40-200

      US$88.46
      New In stock for sale, Mitsubishi Compressor YB645WTG

      Mitsubishi Compressor YB645WTG

      US$549.00
      New In stock for sale, YUKEN Vane Pump PV2R12-19-33-L-REAA-42

      YUKEN Vane Pump PV2R12-19-33-L-REAA-42

      Contact Us
      New In stock for sale, NSK Bearing R 1810

      NSK Bearing R 1810

      US$6.15
      New In stock for sale, Shinko Temperature Controller PCA1R 00-521

      Shinko Temperature Controller PCA1R 00-521

      Contact Us
      New In stock for sale, MAC Solenoid Valve 45A-AA1-DDAJ-1KG

      MAC Solenoid Valve 45A-AA1-DDAJ-1KG

      US$150.77
      New In stock for sale, HITACHI VFD Frequency Converter L300P-220HFE

      HITACHI VFD Frequency Converter L300P-220HFE

      US$2115.38
      New In stock for sale, SMC Solenoid Valve VP3145-035DLB

      SMC Solenoid Valve VP3145-035DLB

      US$1538.85
      New In stock for sale, Baumer Encoder ATD 2A B14 Y 1 360AUSD2SR12S6IP65

      Baumer Encoder ATD 2A B14 Y 1 360AUSD2SR12S6IP65

      Contact Us
      New In stock for sale, REXROTH Relay HED80P1X/350Z14KW

      REXROTH Relay HED80P1X/350Z14KW

      US$107.69
      New In stock for sale, Fuji VFD Frequency Converter FRN220G11S-4CX

      Fuji VFD Frequency Converter FRN220G11S-4CX

      US$17692.31
      New In stock for sale, TYCO Relay V23079-E1208-B301

      TYCO Relay V23079-E1208-B301

      US$13.88

      Recent related posts

      What are the causes of air conditioning trip

      06/20/2020

      What are the causes of air conditioning trip

      What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

      Several issues that need attention in the cold storage verification report in the new GSP requirements

      08/18/2020

      Several issues that need attention in the cold storage verification report in the new GSP requirements

      The new version of the GSP requires that pharmaceutical business and distribution companies must build a temperature and humidity monitoring system, and form a verification report after scientific testing for inspection by the drug regulatory department.

      Refrigeration oil replacement points of screw refrigeration compressors for cold storage equipment

      08/05/2020

      Refrigeration oil replacement points of screw refrigeration compressors for cold storage equipment

      1. The role of lubricating oil:<br></br>   1) A dynamic seal is formed between the screw and the compression chamber and the male and female screws to reduce the leakage of refrigerant from the high pressure side to the low pressure side during the compression process.<br></br>

      It is also a refrigeration equipment, why does the refrigerator not need to add fluoride

      08/12/2020

      It is also a refrigeration equipment, why does the refrigerator not need to add fluoride

      Whether in summer or winter, air conditioners are people's good partners, especially in the hot summer, everyone can say that this life is given by air conditioners.

      Five years of sharpening the sword to rewrite the monopoly pattern of foreign brands

      09/18/2020

      Five years of sharpening the sword to rewrite the monopoly pattern of foreign brands

      "After five years of development and testing, we have successfully developed an oil-free water lubricated single screw air compressor, which broke the long-term monopoly of foreign brands in one fell swoop and became another benchmark for "Creation in Shunde".

      The common oil shortage failures of scroll refrigeration compressors are here

      06/14/2020

      The common oil shortage failures of scroll refrigeration compressors are here

      The compressor has been short of oil for a long time-the mechanism and the friction pairs are overheated, resulting in bearing sintering and shaft holding. The compressor is short of oil for a short time-the mechanism and the friction pairs are abnorma器2䀀ᅵ皥䖒皦즠Ʋ焬क़㲈Ʋ䌁皦

      Three maintenance and inspection methods for air-conditioning refrigeration compressors

      08/19/2020

      Three maintenance and inspection methods for air-conditioning refrigeration compressors

      In order to ensure the normal operation of the compressor and prolong its service life, in addition to regular maintenance and inspection, daily maintenance and inspection are very important.

      Three major causes of compressor cracks in winter

      07/01/2020

      Three major causes of compressor cracks in winter

      Three major causes of compressor cracks in winter When using the compressor in winter, we may encounter some problems, such as cracks in the compressor body. There are many ways to cause cracks in the compressor. After summing up, the specifics can be summarized as the following three points:

      Is the duct air conditioner a central air conditioner Advantages and disadvantages of duct machines and central air conditioning

      08/11/2020

      Is the duct air conditioner a central air conditioner Advantages and disadvantages of duct machines and central air conditioning

      At present, there are mainly three types of household central air conditioners that are popular on the market: one is air-cooled heat pump hot and cold water units, commonly known as water machines (water system central air conditioners);

      What faults frequently occur after the air conditioner is moved

      07/29/2020

      What faults frequently occur after the air conditioner is moved

      Refrigeration system failures are common faults in our maintenance. The failure phenomena are also various and strange, but there are still rules to follow and experience can be used for reference.

      • Welcome to O&Kmarts

        Is there anything we can help?

        Email us
      • Feedback

      Join in

      Join in to enjoy exclusive discounts and give you greater discounts

      See More About O&Kmarts Member
      Sign up now

      Common Problem

      Payment Methods
      Shipping Guide
      Sales and Refund Policy
      FAQs

      About O&Kmarts

      About Us
      Membership

      Website Terms

      Privacy Policy
      Terms Of Use
      Bidding Agreement
      Review Rules

      Customer Service

      support01@okmarts.com
      service@okmarts.com
      hydraulic@okmarts.com
      +86-28-84166335
      GMT+08:00 Mon-Fri, 9:00 AM-7:00 PM
      Customer Feedback

      POPULAR PRODUCTS :

      ASSOMA Magnet Pump PAN WORLD Magnet Pump DATTO Magnet Pump Iwaki Magnet Pump MDK-20S4TS02C MDK-20S4TS02C MD-10K-220NL 25CJT0752 MHMF022L1V2M VE4025B1045 8E5K-22-X VA08H-760 ae4430ys AVC BAZC0925R2U awa9490zxn Camel WE43-G02-C4-A110-N CS AD-20-V-G2 e68s15 1024 6 l 5 edr 150 24 Hitachi SH380RY-C8DU1IN Hitachi SHX33SC4-U Hitachi THU33WC6-E HNB71FA-YBE IMI Norgren 2636404.0000.000.00 jiaxipera MG1060Y kd1209pts1 Moog Servo Valve G631-3006B MSMD021P1S Parker 443798W sc 0 magnetic contactor SNB172FEKMT Ziehl Abegg RH22V-4IP.ZC.BR

      Disclaimer: All brand names, model or type numbers or marks listed on the website are owned by their respective manufacturers. These terms are used for identification purposes only and are not intended to indicate affiliation with OEM companies. Product pictures shown on the website are for illustrative purposes only and the actual item may vary in design, specification, etc. Confirm at the time of purchase if you are unsure.

      © eCommerce. 2017-2026. All Rights Reserved
      © eCommerce. 2017-2026. All Rights Reserved
      Press and drag the mouse to start taking a screenshot