It is applied to many fields, like Automotive Hybrid, electric & powertrain systems Enterprise systems Enterprise projectors Personal electronics Home theater & entertainment .
And the main parameters of this part is: FPGA Spartan-II Family 200K Gates 5292 Cells 263MHz 0.18um Technology 2.5V 208-Pin PQFP.
Additionally, it is green and compliant to RoHS (Lead free / RoHS Compliant).
XILINX IC Integrated Circuit XC2S200-5PQG208C
People who bought this item also viewed
Siemens PLC 6ES7216-2AF22-0XB0
SAMSUNG RAM Card M393A2K40CB2-CVF
Beckhoff Terminal Box Module IP1002-B400
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Contrinex Sensor DW-AD-605-M30
BANDO Belt T2.5-145-24
PIZZATO Switch FL 619-K52
HONGFA Relay HFV6V-12-HT-R(614)
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/12/2021
Mitsubishi Heavy Industries Air Conditioner KXZmini series, excellent quality starts with the selection of parts
When you are in an office building, shopping mall, cinema, restaurant, or at home, you can enjoy the comfortable body feeling brought by the pleasant room temperature. Will you ever be curious? What advanced technology is behind the air outlets, let us Ca 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/13/2020
Piston screw scroll centrifuge compressor characteristics analysis
Piston screw scroll centrifuge compressor characteristics analysis 1. Semi-closed piston compressor Principle: Rely on the reciprocating motion of the piston to compress the gas in the cylinder.
-
06/13/2020
The new air conditioner takes only 5 minutes to evacuate. What is the effect of air conditioning cooling and heating
The new air conditioner takes only 5 minutes to evacuate. What is the effect of air conditioning cooling and heating
-
09/07/2020
Principle and function of temperature control valve of screw air compressor
Each component of the screw air compressor has its unique and important role, such as air filter, oil filter, safety valve, temperature control valve, one-way valve, etc. If one of them is missing, the screw air compressor will not function properly.
-
06/13/2020
Global Refrigeration Compressor Market Overview 2020: Emerson, HITACHI, GMCC, Huangshi Dongbei, Landa
The market study namely Global Refrigeration Compressor Market 2020 by Manufacturers, Regions, Type and Application, Forecast to 2025 shows a focused situation of key industry players combined with their market share, deals, and development prospects.
-
07/22/2020
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
I only learned today that the dehumidification mode cannot be used indiscriminately when the air conditioner is turned on in summer, which consumes electricity and consumes compressors.
-
01/16/2021
Refrigerator compressor maintenance case
Refrigerator compressor maintenance case Case description: The repair is a Refrigerator 220 direct-cooled refrigerator, which starts after the contact is stuck, causing the refrigerator compressor to start normally and sometimes abnormally.
-
09/10/2020
Application of pressure sensor in air compressor control system
Take a single screw air compressor as an example to illustrate the working principle of an air compressor. The working process of a screw air compressor is divided into four processes: suction, sealing and conveying, compression and exhaust.
-
07/08/2020
How to solve the problem of poor oil return of screw chiller
1. What is the cause of the poor oil return of the screw chiller? Generally speaking, the reason for the poor oil return of the screw chiller is mainly due to the phenomenon of the gas mixture of lubricating oil and refrigerant during the operation. Specifically, in the operation of the refrigeration system, encountering the miscibility of the refrigerant and the refrigerator lubricating oil will cause the lubricant in the refrigeration compressor to run and the refrigerant will be discharged into the condenser in the form of gas mist and droplets.