Type | Rotary Servo Motors |
Series | Sigma-5 SGMGV Series |
Rated Output | 300 W |
Voltage | 200 V |
Serial Encoder | 20-bit incremental |
Rotation Speed | 1500 RPM - 3000 RPM |
Specifications | Straight with key and tap |
Options | Without options |
Time Rating | Continuous |
Thermal Class | Class F |
Vibration | 15μm |
Withstand Voltage | 1500VAC 1 min |
Insulation Resistance | 500VDC, 10MΩ minimum |
Enclosure | Totally enclosed, self-cooled, IP67 |
Ambient Temperature | 0 to 40ºC |
Ambient Humidity | 20 to 80% (non-condensing) |
Excitation | Permanent magnet |
Drive Method | Direct drive |
Mounting | Flange-mounted |
Yaskawa Servo Motor SGMGV-03ADA61
People who bought this item also viewed
Yaskawa Servo Motor SGMPH-04DAA61D
Yaskawa Servo Motor SGM7J-01AFA61
Yaskawa Servo Motor SGMAH-07DAA61D-OY
Yaskawa Servo Motor SGMPH-04DAA6CD
Yaskawa Servo Motor SGMAH-08AAN21
Yaskawa Servo Motor SGM7J-01AFA2C
Allen Bradley Servo Motor MPS-B560F-MJ52DF
Yaskawa Servo Motor SGMJV-04A3A21
YUKEN Servo Valve LSVG-03-40-1051
FANUC HMI A61L-0001-0090
Fuji VFD Frequency Converter H7F-5.5-4GA7
SIEMENS Actuator SSA81
COSEL Power Supply CES48033-25-V
DAYTON Speed Reducer 4M297
DIEWU NIC Card 82575-1X
OEG Relay SDT-SH-112DM
TADIRAN Battery SL-350-PR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Furnan Vane Pump 50T-20-FR+PA
Honeywell Sensor 40PC001G2A
Rexroth Piston Pump A2FO160/61L-PBB05
Danfoss Compressor NTZ068A4LR1A
Recent related posts
-
07/19/2020
Basic knowledge of refrigeration compressor
After shutting down, stop for at least 3 minutes before starting again to eliminate the pressure difference between the compressor inlet and outlet. Because in the case of a large pressure difference, the starting torque of the motor will increase, causing the current to rise to a certain level, the protector will act and the compressor cannot continue to run.
-
09/09/2020
Compressor companies have caused the misunderstanding of killing, how many tricks have you hit
In recent years, many machinery manufacturing companies, including the compressor industry, have suffered unprecedented tests. Some are not adaptable due to the transformation of the economic system, and there are also "secret injuries" from the company’s own business strategy.
-
06/24/2020
What is the problem with the poor cooling effect of the air conditioner
In the hot summer, I believe that many people can not do without air conditioning, air conditioning can allow us to spend this summer in a cool environment. However, in the process of using air conditioners, I believe that many people have encountered a situation where the cooling effect of the air conditioner is not good, so why is the cooling effect of the air conditioner not good? What needs to be solved.
-
06/30/2020
Common faults and causes of compressors
Common faults and causes of compressors Common compressor failures are as follows: L. The compressor cannot start normally The power supply voltage is too low, the motor circuit is poorly connected, or the exhaust valve is leaking, resulting in too high pressure in the crankcase. The energy regulation mechanism has failed.
-
09/18/2020
Jingliang Electronics-Air Compressor Sensor Solution
——High-quality, cost-effective to provide customers with perfect sensor solutions Precision Electronics-MEAS (MSI) Sensor Co., Ltd. is a precision electronic engineering expert who masters the world's leading silicon micromachining MEMS technology.
-
04/06/2022
Why Does The Fan Keep Running on My Air Conditioner?
Today, the air conditioning, as an electrical appliance that can adjust the temperature and make people feel cool is welcomed and loved by many people.
-
09/05/2020
What are the main functions and functions of air compressor post-processing equipment
What are the main functions and functions of air compressor post-processing equipment? In an air compressor system, in addition to an air compressor to produce compressed air, post-processing equipment is also required to cool, dry and purify the air.
-
09/09/2020
How to provide air source for air compressor
Is the air compressor better for centralized air supply or more energy-saving for point-by-point air supply; for equipment with small air consumption and low pressure, it may be economical to install a pressure reducing valve to work.
-
11/10/2022
What is an Industrial Fan?
Industrial fans, which can efficiently push a large amount of air and generate super-large air volume. This creates a circulating airflow field in the space.
-
12/16/2023
HVAC Fan Won't Turn off (Troubleshooting Guide)
Having a properly functioning HVAC system is essential for maintaining a comfortable and controlled indoor environment.