YI-SHING Vane Pump VP-12-12-FA2
People who bought this item also viewed
YI-SHING Vane Pump VHIF-30-140
YI-SHING Vane Pump VHIF-F25-25-A
YI-SHING Vane Pump VHIF-F40-A
Camel Vane Pump VCM-SF-15D-20
Yuci Vane Pump PFED-32028-016-1DT
HONGYI Vane Pump 35V21A-1C22R
Camel Vane Pump VCM-SF-15B-30
SMC Proportional Valve ITVX2030-043N
NACHI Check Valve OCP-G01-B1-F-21
HP Overflow Valve MRF-02A-K-2
NACHI Piston Pump PVS-1B-35N2-12
HYDROMAX Gear Pump HGP-2A-F2R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder MAD60X100
Sanyo Denki Fan 9G0812P1H051
Recent related posts
-
02/23/2024
Projector Cooling: How to Effectively Cool Down a Projector
Friends who once used projectors will easily notice a phenomenon: when standing next to the projector, they will feel bursts of hot air. So friends, have you ever wondered why projectors heat up?
-
07/05/2020
PORTABLE AIR COMPRESSOR MARKET SWOT ANALYSIS BY GROWTH AND FORECAST FROM 2020-2026|STANLEY BLACK&DECKER,POWERMATE,CAMPBELL HAUSFELD,SENCO
DataIntelo report titled Global Centrifugal Air Compressor Market provides detailed information and overview about the key influential factors required to make well informed business decision. This is a latest report, covering the current COVID-19 impact on the market.
-
12/29/2023
How to Maintain the Solar Inverter Cooling Fan in Hot Weather?
Solar inverters are generally installed outdoors and are affected by natural factors such as sun, rain, sand, dust or high temperature.
-
07/18/2020
How to protect the refrigeration compressor
Safety operating rules for Freon refrigeration compressor units in cold storage Freon refrigerants are generally used in cold storage refrigeration systems, so the following is a brief introduction to some of the operating specifications of Freon refrigeration units, so that everyone will feel very simple and relaxed when using them.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
05/05/2022
10 Matters When Installing Water Solenoid Valve?
Solenoid valve is one of the commonly used valves in automatic control system. It is favored by users because of its low price, simple use, convenience and reliability.
-
01/05/2021
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes.
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes. Skematic of Compression Refrigeration System
-
08/16/2020
The difference between condenser and cooler
There will be compressors, condensers, evaporators, expansion valves and refrigerants in the chiller refrigeration system. Only with the addition of these original parts will a good refrigeration system be formed.
-
11/09/2021
PLC (Programmable Logic Controllers) and HMI (Human-Machine Interface) for Intelligent Factory
The development of "intelligent factory" has put forward a new direction for manufacturers. It is necessary for manufacturers to master the production and marketing process clearly
-
08/07/2020
Temperature requirements and uses of various cold storage
Temperature requirements and uses of various cold storage<br></br> Different cold storages have different requirements for temperature. Now I will introduce to you