Maximum operating pressure: 25 MPa/3630 psi
Series: sub-plate mounting pilot operated relief valve
Valve size: 06
Maximum flow: 200 L/min(52.8 U.S.GPM)
V: for high venting pressure feature
Yuken Safety Valve BG-06-V-32
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Bosch Filter 0986AF0293
LW Power Supply PS-303DF
AirTAC Air Cylinder SCJ32X65-30
Recent related posts
-
11/07/2022
What is an Electronic Expansion Valve?
The electronic expansion valve is a kind of the expansion valve. It uses the electrical signal generated by the adjusted parameters to control the voltage or current applied to the expansion valve, thereby achieving the purpose of adjusting the liquid supply.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/13/2020
HVAC Innovative products and series of Danfoss commercial compressors
Hello everyone, today I will introduce you to Danfoss' high-temperature compressors.The refrigeration capacity of this series of scroll compressors ranges from 2 to 10 tons, and can be used in parallel. The compressor is divided into three platforms-household, small business and light business. Other features include: two frequencies, 450 kinds of codes.
-
10/15/2021
Piston Compressor Basics - Structure, Working Principle, Advantages and Disadvantages
As both manufacturers and end customers know, in a refrigeration or air conditioning system, the compressor is the equipment core by continuously sucking back and exporting refrigerant
-
09/07/2020
Why is air humid after compression
We all know the importance of compressed air drying. This is a critical step in the compressed air process. If you skip this step, it may cause a large amount of water to accumulate in your system. So why does compressed air get wet?
-
08/14/2020
How to reduce the overall cost of purchasing industrial chillers
How to reduce the overall cost of purchasing industrial chillers
-
08/30/2023
Heat Pump vs Conventional HVAC: Which is Better for Your Home?
When it comes to heating and cooling your home, there are two main options: heat pumps and conventional furnace and AC systems. In this article, we'll take a closer look at heat pumps and conventional furnace and AC systems
-
06/14/2020
An accident analysis of refrigeration compressor
An accident analysis of refrigeration compressor A major refrigerator damage accident occurred in the refrigeration workshop of a meat joint processing plant. The refrigeration workshop of the factory was equipped with 2 single-stage two-stage ammonia re 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž
-
08/07/2020
What should I do if there is water in the refrigerator compartment
In our daily life, many household appliances are used very frequently, but when encountering some emergencies, they feel helpless and have to ask after-sales or repair personnel for help.
-
10/16/2020
Copeland compressor installation steps
The compressor is regarded as the heart of the refrigeration system, and the actual responsibility of the compressor is to increase the pressure and bring the suction pressure state to the discharge pressure state. Emerson Copeland compressors are used in a wide range of applications and have a high degree of attention. Below, okmarts.com will introduce the steps and precautions for installing Copeland compressors.