What should I do if the screw of the rod-type chiller bites to death
Screw chillers are widely used in industry and chemical industry. Screw chiller is just one type of screw refrigeration series. There are also medium and low temperature screw chillers, air-cooled screw chillers, SCY air-cooled screw chillers, water-cooled screw chillers and other equipment that we often come into contact with, all of which belong to the screw refrigeration series.
When the machine is running, it is unavoidable that there will be some problems of this kind or that. It is a metaphor that we often encounter insufficient refrigerant. When such a problem occurs, it will affect the cooling effect of our work. Therefore, in daily work, there are some strict requirements for the staff. They must do a good job of inspection and maintenance during their work. Only in this way can it be guaranteed that there will be no problems when the machine is running.
Today, what we are sharing with you is the treatment method for screw seizure of screw chiller. Some people think that this kind of problem is very difficult, but it is not as difficult to solve as we think.
In the first step, we have to analyze the reasons for the screw seizure, such as: motor burnout, abnormal noise, oil level switch alarm, contactor tripping, liquid injection system failure, terminal failure, water soaking, etc. It is the factor that causes the screw of the screw chiller to seize.
The second step is the processing method we want to adopt. When the oil filter is too dirty and blocked and the oil supply is not smooth, the screw is seized. At this time, the cleanliness of the system should be strengthened and maintained in time. When debugging in the factory, a dirt filter should be installed before the suction filter. After the debugging is completed tear down. It is recommended that the system be equipped with a differential oil pressure switch.
Insufficient oil supply pressure difference (required> 4kg/cm2) will cause the screw to seize after insufficient lubrication; four-way reversing valve blow-by: long-term operation under the condition of 25% capacity adjustment of the unit, unreasonable working conditions, etc., it is recommended to install the unit High and low dropout switch. Compressor reverse rotation causes wiring errors. Observe the high and low pressure changes when starting up and debugging. The unreasonable system matching caused by the loss of oil in the compressor may cause wet compression, etc., which may cause adjustment of the expansion valve or improvement of the unit. Note: Do not short-circuit the oil level switch. Long-term severe hydraulic compression will cause the screw to deform and seize. Check and repair in time.
The third step, the last thing we have to do is to make careful records during the work. Record the operation of the machine every day, keep a record of shifts, and maintain the chiller equipment frequently. Good maintenance will extend the service life of the machine.
What should I do if the screw of the rod-type chiller bites to death
Recent related posts
-
08/16/2020
What should I do if the screw of the rod-type chiller bites to death
Screw chillers are widely used in industry and chemical industry. Screw chiller is just one type of screw refrigeration series. There are also medium and low temperature screw chillers, air-cooled screw chillers,
-
08/16/2020
What to pay attention to when the refrigeration equipment is moved
Because the company needs to change the working environment, all the equipment of the company must be moved, and the refrigeration equipment in the disassembly and installation process requires staff with rich professional knowledge,
-
08/16/2020
Where is the key technology of ammonia refrigeration system construction
1. Refrigeration compressor installation Before the refrigeration compressor is in place, clean the soil and dirt from its bottom and foundation bolt holes, and clean up the foundation surface that has passed the acceptance.
-
08/16/2020
Why is the temperature too low after the cold storage is installed
After the cold storage is built, the first thing should be tested, so that we can know whether there will be problems after the cold storage is installed. Such a problem needs to be considered in the initial stage of the general cold storage installation.
-
08/15/2020
What should I do if wall cracks appear after the cold storage is built
After the construction of the cold storage project, there may be many problems. For example, we have seen a lot of news recently. It is said that the wall cracks appeared after the construction of the cold storage
-
08/15/2020
What should I do if the refrigeration performance of industrial refrigerators declines
When many enterprise users use industrial refrigerators, due to the lack of knowledge about the use and maintenance of equipment, industrial refrigerators are prone to various failures
-
08/15/2020
What should I do if the refrigeration equipment does not operate normally
Nowadays, in order to prevent the goods from selling well and causing economic losses, more and more businesses are using Xuzhou refrigeration equipment to store excess goods or sell them in anti-seasonal times.
-
08/15/2020
What should I do if the cold storage is moldy How to physically remove mildew
Mold generally grows in dark and humid places and can adapt to lower temperatures. Usually in high temperature storage, the situation is serious. Mold grows in the cold storage, and the spores will fly everywhere, which will contaminate the goods and products stored in the storage.
-
08/15/2020
What should be paid attention to when handling refrigeration equipment
Precautions for the handling of refrigeration equipment-Do not put it down during transportation. A series of matters must be paid attention to during the transportation of refrigeration equipment.
-
08/15/2020
What are the matters needing attention when installing rock wool board in cold storage
Many businesses now have their own cold storage and install semi-hermetic refrigeration compressors, through which food can be well preserved. So what should we pay attention to when installing rock wool board in the cold storage.
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
EAO Switch 82-6151.1123.B001
SAMXON Capacitor 250V 820UF
Banner Light Curtain SLPP14-410P8
WAGO Relay 857-718