Fluid: Air(to be filtered by 40u m filter element)
Mounting type: Basic FA LB TC TCM1
Operating pressure: 0.15 to 1.0 Mpa(22 to 145psi)(1.5 to 10.0bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second): 30 to 800
Cushion type: Variable cushion
Bore size: 160mm
Stroke1: 700mm
Stroke2: 700mm
AirTAC AirPneumatic Cylinder SCT160X700X700 StandardPneumatic Cylinder(Double acting muti-position type)
People who bought this item also viewed
MINDMAN Air Cylinder MCQV2-11-40-200
Compact Air Cylinder QJ92-1642-A
AirTAC Air Cylinder ACQ80X40
AirTAC Air Cylinder SC63X150S
AirTAC Air Cylinder ACQ40X20
AirTAC Air Cylinder HLH16X10S
Festo Air Cylinder DSNU-16-30-PPV-A
Festo Air Cylinder DNU-50-125-PPV-A
CKD Air Cylinder LCSQ-0830
Festo Air Cylinder ADVU-25-60-A-P-A
Nemicon Encoder HEF-2048-2MHC
CML Solenoid Valve WE42-G02-B8B-A240-N
Belimo Actuator BLF24
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
BOSCH Battery GBA 18V 4.0AH
TAKAMISAWA Relay LZ-12S 12VDC
HOBO Level Meter MX2001-04
Recent related posts
-
01/03/2023
How does Solenoid Coil Work?
Solenoid coils are built using the presence of a magnetic field around a wire. It is wound in a spiral shape to strengthen the magnetic field, i.e.
-
05/31/2022
How to Choose The Right PC Power Supply?
Power supplies are often overlooked, but they are a vital component in any desktop PC. We’re going to cover the basics, so you’ll know what to look for when selecting a new PSU.
-
08/18/2021
How to Repair Your Servo Motor
First, you need to do the following things before starting the servo motor. Measure the insulation resistance (for low voltage motor it should not be less than 0.5m).
-
08/02/2020
When air conditioners lack fluoride, five common leak detection methods will teach you who don’t understand!
When the air conditioner is lack of fluoride, the detection of leaks is the primary task of leakage repair. Today we introduce five common leak detection methods for you, namely fluorescent leak detection, soapy water leak detection
-
08/11/2020
Pay attention to these details. The air energy heat pump can be used for more than 10 years.
In a few months, the northern heating season will officially begin. In addition to central heating, this year's "coal-to-electricity conversion" has also received much attention.
-
08/26/2020
Overview of Screw Refrigeration Compressor Technology
Screw compressors, also known as screw compressors, are divided into single screw compressors and twin screw compressors. The single screw compressor was developed by Sinn, France in the 1970s.
-
06/22/2020
Why is the air conditioner not cooling
Why is the air conditioner not cooling There are many factors for not cooling, for example: the selected air conditioner does not match the area of the room; improper installation of the air conditioner will cause the air circulation of the air conditioner to be unsmooth; when the indoor temperature is relatively high, the air conditioner cannot be cooled when turned on; It has been aging, or the service life has expired; the air conditioner has not been cleaned for a long time, and the filter surface is covered with dust; and the freon of the air conditioner has been seriously lacking. <img src="{{media url="magefan_blog/Why_is_the_air_conditioner_not_cooling.jpg"}}" alt="" />
-
09/15/2020
The technical status and development trend of air compressor
I. Introduction Compressor is a machine used to increase gas pressure and transport gas, and belongs to a working machine that converts the power energy of the prime mover into gas pressure energy. It has a wide range of types and uses, and is known as "general machinery".
-
08/11/2020
Principles and characteristics of heat recovery series air conditioning units
With the growth of China’s economic power and the continuous improvement of people’s material and cultural living standards; the rapid development of high-rise buildings,
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.