Fluid: Air(to be filtered by 40u m filter element)
Mounting type: Basic FA LB TC TCM1 Operating pressure:
Double acting: 0.15 to 1.0 Mpa(22 to 145psi)(1.5 to 10.0bar)
Single acting: 0.2 to 1.0 Mpa(28 to 145psi)(2.0 to 10.0bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second):
Double acting: 30 to 500
Single acting: 50 to 500
Cushion type: Bumper
Bore size: 80mm
Stroke: 140mm
AirTAC AirPneumatic Cylinder SDA80X140S CompactPneumatic Cylinder(Double acting)
People who bought this item also viewed
MINDMAN Air Cylinder MCMB-11-40-75-A
Compact Air Cylinder SD34X12
Festo Air Cylinder DNC-40-1000-PPV-A
AirTAC Air Cylinder TR6X20S
AirTAC Air Cylinder ACQ125X50S
AirTAC Air Cylinder SC40X50
AirTAC Air Cylinder ACQ32X25S
Festo Air Cylinder ADN-50-50-A-P-A
Festo Air Cylinder DZF-63-20-A-P-A
Festo Air Cylinder DGSL-8-50-P1A
Festo Air Cylinder DFM-20-40-P-A-KF
Belimo Actuator GM24A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Camel Vane Pump VCM-DF-40C-40C-10
STYLE Fan US80B23
KROM Switch DG500B-3
Mitsubishi Servo Motor HF-SP441BK-S1
Copeland Compressor ZR108KCE-TFD-551
HENGYI Vane Pump VCM-SF-40C-20
Recent related posts
-
08/19/2020
How to speed up the evaporation and heat dissipation of cooling tower water
In the process of water cooling in the cooling tower, the water is formed into very small water droplets or very thin water film, which expands the contact area of water and air and prolongs
-
08/11/2020
How to use semi-hermetic refrigeration compressor to save energy
The increasing population has made the problem of scarcity of resources increasingly serious, especially some non-renewable resources, which have become the focus of the struggle between countries.
-
06/13/2020
Is there any problem with compressor oil return
Is there any problem with compressor oil return 1. Mechanism analysis of compressor oil shortage During the operation of the system, the lubricating oil is discharged from the compressor along with the refrigerant, and then returned to the compressor 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ
-
08/18/2020
Reasons for the high low pressure value of the chiller
In the application of industrial refrigeration, the chiller is used in conjunction with production and processing equipment, so it runs for a long time. If the customer lacks professional maintenance and routine equipment maintenance for the chiller in daily life
-
01/04/2023
Tips for Solenoid Coil Winding
The solenoid coil is a device that uses the principle of electromagnetic induction to work. When a current flows through a wire, a certain electromagnetic field is generated around the wire. It is regularly wound.
-
08/05/2020
The purpose, method and choice of cold storage system defrosting
The purpose, method and choice of cold storage system defrosting
-
09/02/2020
The difference between centrifugal air compressor and screw air compressor!
Centrifuge and screw air compressor are currently the air compressors with a high market share. Today, I will tell you what are the differences between centrifuges and screw air compressors. I hope this article can help you.
-
06/30/2020
Broken suction valve of Bristol compressor
Broken suction valve of Bristol compressor A Bristol compressor is a machine that compresses gas. Generally, the piston compresses gas 1450 times per minute (half-sealed compressor) or 2900 times (full-sealed compressor), that is, the time to complete an intake or exhaust process is 0.02 seconds or even shorter.
-
08/24/2021
What Motors can be Used with VFD - Three-Phase Induction Motor
The ordinary three-phase asynchronous motor can be used with the variable frequency drive (VFD). Through the analysis of its main market share
-
09/21/2020
Refrigeration system failure symptoms
Symptoms of refrigeration system failure 1. Detection of pressure and temperature of refrigeration system (1) The pressure concept of the refrigeration system The refrigeration system can be divided into high and low pressure during operation. The high pressure section is from the discharge port of the compressor to before the throttle valve. This section is called the evaporation pressure.