Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.1 to 1.0 Mpa(15 to 145psi)(1.0 to 10.0 bar)
Single acting: 0.2 to 1.0 Mpa(28 to 145psi)(2.0 to 10.0 bar)
Proof pressure: 1.5MPa(215psi)(15bar)
Temperature(degrees Celsius): -20 to 80
Speed range(mm per second):
Double acting: 30 to 500
Single acting: 50 to 500
Magnet: With magnet
Bore size: 100mm
Stroke: 15mm
AirTAC Air Cylinder Pneumatic ACQJ100X15S Model:Compact Cylinder Pneumatic(Adjustable stroke)
People who bought this item also viewed
MINDMAN Air Cylinder MCMJ-11-10-10-B
CKD Air Cylinder SCPG2-M-00-10-30
AirTAC Air Cylinder ACQ12X10
AirTAC Air Cylinder ACQ20X30
AirTAC Air Cylinder HRQ7
KOGANEI Air Cylinder ORV16X450
Festo Air Cylinder SLT-20-40-A-CC-B
CHANTO Air Cylinder ASR50X50
Festo Air Cylinder ADVU-100-25-P-A
Eltra Encoder EL58B2500S5L10X3PA
SMC Solenoid Valve SY7240-5GZD-02
Johnson Controls Actuator M9106-AGA-5
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Solenoid Valve JMN1H-5/2-D-2-C
Schneider Circuit Breaker EZD630E3600PK
NEC Relay EC2-12NU
Fuji Relay MS4SY-APB
Eltra Encoder EL40B2500Z5L6X6PA
CAHO Temperature Controller H721SRR2-T
Recent related posts
-
11/14/2021
What is Configuration Software? - HMI/ MMI/ SCADA
Configuration software is a control system composed of HMI (Human and Machine Interface) / MMI (Man and Machine Interface)/ SCADA (Supervisory Control and Data Acquisition).
-
06/14/2020
Cold storage system composition control and operation process
Cold storage system composition control and operation process 1. Composition of small cold storage system As shown in the figure, the figure is a refrigeration device composed of a cold storage, mainly including: refrigeration compressor, chiller, therm 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ
-
03/02/2022
Factors Affecting Air Compressor Performance in Long-Period Operation
Through the research on the use and periodic failure factors of compressors in recent years, it is known that bearing clearance.
-
08/14/2023
Are Window Heat Pumps Efficient? (Window Heat Pump: Everything You Need to Know)
Window heat pumps (heat pump window units, window unit heat pumps) are a popular heating and cooling solution for homes and apartments. They are affordable, easy to install, and can help save energy compared to other heating and cooling options.
-
08/08/2023
How to Defrost a Heat Pump: A Comprehensive Guide
Heat pumps are an essential component of HVAC systems that provide both heating and cooling solutions for homes and commercial buildings. However, like any other mechanical device, they require maintenance and care to operate efficiently and effectively.
-
08/19/2020
Application of large temperature difference cooling water system in industrial cooling system
In the industrial cooling system, in order to meet the process requirements, small flow materials need to be cooled with a large temperature difference (for example, a certain juice beverage needs to cool the material from 30°C to 5°C
-
06/14/2020
A compressor is a fluid machine that raises low-pressure gas to high-pressure gas
It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the motor
-
07/27/2020
Don't know the refrigeration and air conditioning compressor? Understand the following points and know what it does!
In air conditioning and refrigeration systems, the compressor plays a role in compressing and transporting refrigerant gas. The expansion valve plays the role of throttling and reducing pressure
-
08/20/2020
How to prevent high temperature alarm of industrial chiller in summer
In the high temperature and hot summer, the frequency of use of industrial chillers is the highest in a year, and summer is also the season when industrial chillers have the most frequent high temperature alarms.
-
08/05/2020
The difference between the three types of evaporators dry, flooded, and falling film evaporators
The refrigerant in the dry evaporator passes through the heat exchange tube, and the cold water runs outside the high-efficiency heat exchange tube. Such a heat exchanger has relatively low heat exchange efficiency,