Fluid: Air(to be filtered by 40u m filter element)
Operating pressure:
Double acting: 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar) or 0.1 to 0.7 Mpa(15 to 100psi) (1.0 to 7.0 bar)
Single acting: 0.3 to 0.7 Mpa(36 to 100psi)(3.0 to 7.0 bar)or 0.2 to 0.7 Mpa(28 to 100psi)(2.0 to 7.0 bar)
Proof pressure: 1.1MPa(160psi)
Temperature(degrees Celsius): -20 to 70
Speed range(mm per second): 30 to 500 or 50 to 800
Cushion type: No cushion or Bumper
Bore size:10mm
Stroke:10mm
Magnet:without magnet
AirTAC Air Cylinder Pneumatic PB10X10Pen size Cylinder Pneumatic(Double acting)
People who bought this item also viewed
Compact Air Cylinder SD34X12
Festo Air Cylinder AEVULQZ-16-10-P-A
Festo Air Cylinder SLG-18-200-YSR-A
AirTAC Air Cylinder TR6X50S
AirTAC Air Cylinder ACQ32X30S
AirTAC Air Cylinder MD16X40S
AirTAC Air Cylinder TR16X30S
AirTAC Air Cylinder SC50X50
MINDMAN Air Cylinder MCGB-03-16-75
Festo Air Cylinder DGSL-25-150-Y3A
Festo Air Cylinder ADN-50-40-I-P-A
HENGSTLER Encoder RI58-O/120ES.41KF
UNIVER Solenoid Valve AA-0402III-19
Honeywell Actuator OM-P2-E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
EMERSON Power Supply ECM3-18
AirTAC Air Cylinder SC80X975S
LEEMIN Filter LH0060D010BN4HC
NEW-ERA Air Cylinder HP07-8JB
Keyence Sensor PX-10P
Recent related posts
-
06/13/2020
The principle of auxiliary equipment of air conditioning and refrigeration system
The principle of auxiliary equipment of air conditioning and refrigeration system (1) In air conditioning and refrigeration, in order to enable the reliable and stable operation of the refrigeration system and improve the economics of operation
-
08/12/2020
Have you figured out the "enthalpy" and "entropy" of the refrigeration system?
1. Enthalpy<br></br> It is a kind of energy, used to indicate the thermal state parameter of the state of the refrigerant, it represents the size of the total energy of the refrigerant; namely:
-
07/14/2020
Analysis on energy saving and consumption reduction of compressed air system
Analysis on energy saving and consumption reduction of compressed air system Compressed air is widely used in the industrial field due to its safety, environmental protection, good adjustment performance, convenient transmission, convenient centralized management and application, and good working environment applicability.
-
12/05/2022
Top 7 Linear Guideway Brands
The linear guideway, also known as the linear guide, is used for high-precision or high-speed linear reciprocating motion.
-
05/23/2022
Working Principle and Composition of Safety Light Curtain?
Safety light curtain is generally used in high-risk mechanical equipment such as punch press, stamping and non-standard machinery to protect workers from personal injury.
-
06/13/2020
The Package of Compressor and H series Gas Turbine
The Mitsubishi Hitachi Power Systems H-100 100 MW Class twin shaft gas turbine is ideally suited as a main refrigeration compressor driver for 4 to 6 mtpa LNG plant
-
06/13/2020
Take you to understand the development status of Chinese air compressor industry
According to statistics, in recent years, China's air compressor output has been increasing year by year. In the future, compressed air system energy-saving services will transform the energy-saving control of single equipment to the energy-saving design ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ
-
08/20/2020
Cold storage anti-corrosion and anti-frost coatings effectively solve the problem of frosting and corrosion
In the cold storage, when the dew point of the air is lowered by the cooling pipe surface, the moisture in the food and air will precipitate and condense on the pipe wall. If the pipe wall temperature is lower than 0°C, it will condense into a rain layer.
-
09/07/2020
Year-end overhaul of compressor equipment in tire service industry
Partial maintenance of oil-water separator The main function of the oil-water separator is to adjust the system pressure and ensure system lubrication. Insufficient system pressure will cause the tire changer to work weakly, and lubrication failure will cause damage to the tire changer cylinder or wasted oil injection.
-
08/19/2020
5 common causes of refrigeration system failures and solutions
1. The suction temperature is too high-mainly caused by the increase of suction superheat. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam.