Temperature:-20...70 degrees Celsius
Port size(Note):M5X0.8
Note:PT thread,G thread and NPT thread are available.
AirTAC Air Cylinder TCLJ12X60-20S
People who bought this item also viewed
MINDMAN Air Cylinder MCMJ-11-10-10-B
CKD Air Cylinder FCD-L-40-35
AirTAC Air Cylinder SCJ125X100-100
AirTAC Air Cylinder TCM16X30S
AirTAC Air Cylinder SE40X230
AirTAC Air Cylinder MA25X550SCM
SHAKO Air Cylinder IC40C100
Festo Air Cylinder DNC-32-25-PPV-A
CKD Air Cylinder CMK2-LB-20-100
Festo Air Cylinder ADN-16-15-I-P-A
KOGANEI Solenoid Valve 113-4E1-PSL
SIEMENS Actuator GEB164.1E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Camel Vane Pump VCM-DF-20B-20B-10
KOGANEI Air Cylinder DA20X50-A
YUKEN Vane Pump A37-F-R-03-H-S-K-32
Beckhoff Coupling Module BK9053
MINDMAN Air Cylinder MCMA-11-40-90
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/07/2020
Common physical and chemical methods for removing scale in condensers in chillers
The water chiller is prone to scale formation in the condenser pipe after long-term use. If it is not treated in time, these scales will affect the heat exchange effect and cause the condensing temperature of the unit to increase
-
07/22/2020
The ranking of compressor industry companies has changed so much
Due to the high technical threshold and high capital investment of the compressor industry, the concentration of the top five brands of the five major compressors in the industry has exceeded 63%, but the five major products also reflect different differentiation and evolution trends.<br></br>
-
06/23/2020
The air conditioner suddenly stopped cooling.
1.The air conditioner remote control may not adjust the temperature. 2. It may be that the air conditioner has not been cleaned for too long, which causes dust to accumulate on the filter net, so that the cold air blocking the air conditioner cannot be blown out. 3. There may be leakage of freon in the air conditioner, resulting in too little freon, and the air conditioner is not cooled. 4. Energy saving is due to unstable voltage, which causes the air conditioner to not be cooled. 5. It may be that the number of air conditioners is insufficient, and the small number of horses is not used for cooling in a large area of the house.
-
09/06/2020
Dry air compressor sales, please keep these seven words in mind!
move】 Work does not raise idlers, and the team does not raise idlers. Go every day, not afraid of thousands of miles; Do it often, not afraid of everything.
-
06/14/2020
Why does the refrigeration compressor frost and the solution!
Why does the refrigeration compressor frost and the solution! 1. The frost on the compressor return air port indicates that the temperature of the compressor return air is too low, so what will cause the compressor return air temperature to be too low? 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ӄ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
06/14/2020
Refrigeration compressor classification overview
Refrigeration compressor classification overview The compressor is the core equipment in the refrigeration system. Only by converting electrical energy into mechanical work and compressing the low-temperature and low-pressure gas refrigerant into high- 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧
-
04/22/2024
FANUC Servo Amplifier Alarm Codes and Solutions (SV401~SV423)
Relying on its strong R&D capabilities and rigorous work style, FANUC continues to develop epoch-making products, making the FANUC CNC system one of the most widely used and recognized systems on the market today.
-
03/10/2021
The main circuit fuse fusing is a common fault of SCR servo driver. The causes of fuse fusing are as follows
The "phase sequence" of power incoming line is incorrect. Due to the synchronization problem between the trigger pulse and the main circuit of SCR servo driver, there are strict requirements on the "phase sequence" of the input power supply. If the "phase sequence" is not correct, connecting the power supply may immediately cause the fuse of the main circuit of the driver to blow.
-
06/14/2020
Do summer air-conditioning rooms need air purifiers
Do summer air-conditioning rooms need air purifiers It is high temperature in summer again. Many people have disputes about whether an air purifier is needed in summer.