08/17/2020
Analysis of 4 major reasons for the high energy consumption of building HVAC systems
1. Analysis of the high energy consumption of the building HVAC system The reasons for the high energy consumption of building HVAC systems are mainly reflected in the following aspects:
-
08/25/2020
Mitsubishi inverter air conditioner basic principle training
1. The difference between inverter air conditioner and fixed frequency air conditioner <br></br> 1. Different compressors
-
07/28/2021
Daikin Vs. Toshiba Air Conditioners
Daikin in Japan has always maintained the first market share, is the world's only multinational enterprise integrating the air conditioner
-
06/14/2020
How to solve the problems encountered during the operation of 120KW cold air-cooled compressor
The 120KW cold capacity air-cooled compressor mainly has three related systems: refrigerant circulation system, water circulation system and automatic electrical control system.
-
09/06/2020
What kind of knowledge is choosing an air compressor
The air compressor market is mixed. There are all kinds of air compressors of all brands, and consumers will inevitably be confused. How to distinguish between true and false, how to distinguish between good and bad,
-
07/07/2020
Why defrost cold storage What are the ways to defrost
Why defrost cold storage What are the ways to defrost I. Overview: The frost on the surface of the evaporator in the cold storage hinders the conduction and distribution of the cooling capacity of the refrigeration evaporator (pipe), which ultimately affects the cooling effect.
-
08/02/2020
How to determine the refrigerant leakage of the air conditioning system Only need these six steps
Shut down and unplug the air conditioner (to prevent danger during the inspection process), and connect a pressure gauge to the large valve. Observe the static pressure.
-
03/12/2021
Four control modes of servo drive
1.Feedback compensation open loop control. The accuracy of open-loop system is low, because the step error , start stop error and mechanical system error of servo driver will directly affect the positioning accuracy. This system has the advantages of both open-loop and closed-loop, that is, it has the stability of open-loop and the accuracy of closed-loop.
-
07/17/2020
The effect of insufficient refrigerant charge on the chiller
1. If the suction pressure and discharge pressure of the compressor are lower than the normal value, then you need to check to see if it is due to insufficient refrigerant charge.
-
10/12/2021
What are the Major Causes of Variable Frequency Drive (VFD) Damage?
The larger the setting value, the higher the gain and the greater the stiffness. Under the same frequency command pulse condition, the position lag will be smaller.