Type | Analog outputs modules |
System | X20 System |
Description | X20 analog output module, 2 outputs, 10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution |
B&R ID code | 0x1BA2 |
Power consumption | 0.01 W |
CE | Yes |
UKCA | Yes |
ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc,IP20, Ta (see X20 user's manual),FTZÚ 09 ATEX 0083X |
UL | cULus E115267,Industrial control equipment |
HazLoc | cCSAus 244665,Process control equipment,for hazardous locations,Class I, Division 2, Groups ABCD, T5 |
DNV | Temperature: B(0 to 55°C),Humidity: B(up to 100%),Vibration: B(4 g),EMC: B(bridge and open deck) |
LR | ENV1 |
KR | Yes |
ABS | Yes |
BV | EC33B,Temperature: 5 - 55°C,Vibration: 4 g,EMC: Bridge and open deck |
EAC | Yes |
KC | Yes |
Output | ±10 V or 0 to 20 mA / 4 to 20 mA, via different terminal connections |
Digital converter resolution | ±12-bit |
Settling time on output change over entire range | 1 ms |
Data output rate | - |
Electrical isolation | Channel isolated from bus,Channel not isolated from channel |
Degree of protection per EN 60529 | IP20 |
Operating temperature | -25 to 60°C |
Operating Relative Humidity | 5 to 95%, non-condensing |
Pitch | 12.5+0.2mm |
B&R Controller Module X20AO2622
People who bought this item also viewed
B&R Controller Module 2DS100.60-1
B&R Controller Module 7CP430.60-1
B&R Controller Module 3PS477.9
B&R Controller Module 3IP151.60-2
B&R Controller Module 3PS465.9
Beckhoff Module EL2521-0024
Beckhoff Module EL1012
B&R Input Output Module 3DI486.6
Yaskawa Servo Motor SGMPH-01ABA2C
Panasonic Servo Drive MSD2A321E
Kwangwoo KW Encoder RIB-50-0720ZV
Omron PLC 3G2A5-OC224-E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCQV2-11-32-120
SAWANA Relay JS48J-A(DH48J-A) DC12V
Recent related posts
-
06/22/2020
What's wrong with air conditioning and cooling
1.The air conditioner lacks freon. Under such circumstances, the air conditioner cooling effect will be poor. 2. If there is a lot of dust and dirt in the filter, it will affect the heat dissipation effect, which will affect the cooling. 3. The outdoor temperature is too high, and it is difficult to lower the temperature by turning on the air conditioner at home. 4. Voltage problem, the power supply voltage of normal air conditioner is 220V, but if it is lower than 220V, the cooling effect will be greatly affected. Summer is coming soon, and the weather is getting hotter. But if the cooling effect of the air conditioner is not good after turning on, what is going on? Is there any good solution? <img src="{{media url="magefan_blog/What_s_wrong_with_air_conditioning_and_cooling.jpg"}}" alt="" />
-
08/15/2020
How to install large-scale cold storage refrigeration equipment
The cold storage is mainly used as a constant temperature storage air-conditioning equipment for food, dairy products, meat, aquatic products, etc. The cold storage is a kind of low-temperature cold storage and also a kind of refrigeration equipment.
-
06/14/2020
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
Analysis and solution of the three reasons for the high temperature of the exhaust of the compressor dryer
-
08/07/2020
Use and selection of water pumps for HVAC systems
1. Chilled water pump:<br></br> In the chilled water loop, a device that drives water to circulate. The end of the air-conditioned room (such as fan coil, air handling unit, etc.)
-
08/07/2020
Three circulation systems of industrial chillers
Water chillers play a very important role in the industry. They are needed in the refrigeration process of electroplating, chemical, printing, pharmaceuticals, plastics and other industries. Due to the wide range of applications of chillers
-
07/17/2022
How to Repair Gear Pump
In the previous article, we introduced a lot about the gear pump, so how to install the gear pump? Let's talk about it today.
-
07/01/2020
Several advantages of screw compressor
Several advantages of screw compressor In the cold storage installation, the choice of refrigerator is to choose to use screw machine or piston machine. The use of screw machines is gradually surpassing the share of the original piston machines.
-
09/04/2020
From the buying habits of motor users, how to better promote high-efficiency motors
Motor energy saving is a key project in industrial energy saving, and the motor system energy saving project is also one of the key energy saving projects designated by my country.
-
08/07/2020
Working principle of frequency converter
Inverters can be divided into voltage type and current type inverters.<br></br> Voltage type is an inverter that converts the DC of a voltage source to AC. The filtering of the DC loop is a current type that converts the DC of the current source to A
-
08/27/2020
Design and Application of Universal Crank and Connecting Rod Mechanism
First, let me introduce the function of the crank connecting rod mechanism to the internal combustion engine: 1) convert heat energy into mechanical energy; 2) piston reciprocating linear motion becomes crankshaft rotation motion; 3) output continuous power to related transmission devices.