There is no price at present, you can Request a Quote
Baldor Servo Drive FMH2A06TR-EN23?
There is no price at present, you can Request a Quote
People who bought this item also viewed
Allen Bradley Servo Drive 1394-SJT10-C-RL
Panasonic Servo Drive MCDDT3120003
Mitsubishi Servo Drive MR-J2S-500A
Fanuc Servo Drive A06B-6320-H343
Yaskawa Servo Motor SGM7J-02AFA61
LS Mecapion Encoder S58-10-1200ZC
Mean Well Power Supply HLP-60H-24
KOYO PLC H2-CTRIO
JSCC Speed Reducer 90GF25HE
MITSUBISHI Spindle Amplifier MDS-DH-SP-40
Winyao NIC Card WY546LX
HAWKER Battery 12HX400-FR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CRYDOM Contactor DRC3P48D4002
NACHI Check Valve OC-G01-T1-21
Recent related posts
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/08/2020
How to change the central air conditioner to be good for wind power
How to change the central air conditioner to be good for wind power 1. The conversion refrigeration of air conditioning becomes higher In order to control the balance function that runs during the operation of the parts, the central air-conditioning projﰨ2 䀀 湠疖 V ǜ
-
08/11/2020
Installation conditions and precautions of refrigeration compressors
The selection of the installation site is most ignored by the staff. Often after the compressor is purchased, you can find a location and use it immediately after piping. There is no prior planning at all.
-
06/20/2020
Air compressor selection_air compressor parameters
Air compressor selection_air compressor parameters Air compressor selection <img src="{{media url="Air_compressor_selection_air_compressor_parameters.jpg"}}" alt="" /> How to choose an air compressor in a reasonable way should comprehensively consider the comprehensive technical and economic indicators such as the investment and operating costs of the air compressor unit and the air compressor station, so that it conforms to the principles of economy, safety and application. Specifically, there are the following aspects:
-
08/06/2020
Principles that need to be followed when using antifreeze in industrial chillers
Principles that need to be followed when using antifreeze in industrial chillers<br></br> The role of antifreeze for industrial chillers is to prevent expansion and cracking of heat exchangers, pipes or engine cylinder blocks due to the freezing of the coolant.
-
03/03/2023
Test and Diagnosis of Cylinder Sealing
Cylinder sealing is guaranteed by engine piston group, valve and valve seat, cylinder head, cylinder block, cylinder gasket and other parts.
-
08/11/2020
Installation of fittings of air-conditioning water system
Air-conditioning water system includes cooling water system (cooling water pipe, pump, cooling tower, condenser, valve, etc.), chilled water system (chilling water pipe, pump, terminal, valve, insulation, expansion tank, etc.) and condensate water system
-
08/11/2020
How to use semi-hermetic refrigeration compressor to save energy
The increasing population has made the problem of scarcity of resources increasingly serious, especially some non-renewable resources, which have become the focus of the struggle between countries.
-
06/13/2020
Comparison of working principle of single screw and twin screw refrigeration compressors
Comparison of working principle of single screw and twin screw refrigeration compressors 1. Twin screw compressor Twin-screw refrigeration compressor is an energy-adjustable oil-injected compressor. Its three consecutive processes of suction, c 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ҵ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ