Our oil-less compressors deliver quiet, cool operation and long vane life.
Besides 100% oil-less operation, these compressors also feature:
* Direct drive
* Long vane life
* Inlet filter standard
* Pressure regulator included
* Minimal maintenance
* Continuous duty rated
*
Model DT 4.16
Horsepower 0.94
CFM @ Open Flow 11.2
Max. Pressure (PSIG) 15
Noise Level (dBa) 64
Becker Vacuum Pump DT4.16K
People who bought this item also viewed
NASH Vacuum Pump 2BV2061ONC022P
NASH Vacuum Pump 2BV2070ONC002P
JK Magnet Pump JKX-F-665-T-C-V
AQUA Water Pump AU200-1.5HP
Burgmann Mechanical Seal 59U-40
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TECO Servo Motor JSMA-MB20ABK01
CROWN Fan AGE02510B12M
Nemicon Encoder OVF-12-2MHT
Recent related posts
-
09/11/2020
Ways to reduce bearing noise
Ways to reduce bearing noise (1) Method of using chemical additives Adding certain chemical additives to the bearing lubricant can reduce bearing noise. For example, a low-noise grease containing noise-reducing additives produced by a factory in Tianjin can reduce bearing noise by 3.9-9.2dB from the original basis. , Suitable for use in miniature or small bearings.
-
07/23/2020
R410a and R22 refrigerant comparison application and installation specifications
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
-
07/16/2020
Analysis of the reason why cold storage should not be built underground
Many people think that building cold storage underground will have better thermal insulation effect than cold storage on the ground, because in the past, when the technology was backward, it was very common to choose cellars as crop storage. But from a commercial point of view, it is not scientific to blindly build the cold storage underground. The cold storage construction team stands from the perspective of consideration for customers
-
07/02/2020
The compressor lacks oil, so the harm is so great!
The compressor lacks oil, so the harm is so great! Compressors are complex machines that operate at high speeds. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, and pistons is the basic requirement for maintaining normal operation of the machine.
-
05/11/2022
Mitsubishi air conditioner E1, E2, E3, E4, E5, E6 and other faults, how to troubleshoot and repair?
Whether there is a fault in the indoor and outdoor units can be known by the access code of the remote control, the content of the green LED
-
01/27/2022
Four Methods to Maintain the Central Air Conditioner Compressor
The compressor is the heart of the central air conditioner. It is located in the outdoor air conditioning unit.
-
07/19/2020
The principle structure, advantages and disadvantages of scroll refrigeration compressor
Principle: The scroll line pattern of the moving plate and the static plate are the same, but the phase difference is 180°C; they mesh to form a series of closed spaces; the static plate does not move, and the moving plate revolves around the center of the fixed plate with the eccentricity as the radius. When the moving disc revolves, it meshes in sequence, so that the crescent-shaped area is continuously compressed and reduced, so that the gas is continuously compressed and finally discharged from the center hole of the static disc
-
07/22/2020
The working principle of cooling and heating of air conditioning
In addition to the cooling function, the heating and cooling air conditioner also has the heating function. The biggest difference from a single-cooling air conditioner is that an electromagnetic four-way reversing valve is installed in the heating and cooling air conditioner.
-
06/21/2020
Refrigeration, Air Conditioning Compressors: Reciprocating, Rotary, Screw, Centrifugal, Scroll
What is Refrigeration Compressor The compressors are one of the most important parts of the refrigeration cycle. The compressor compresses the refrigerant, which flows to the condenser, where it gets cooled. It then moves to the expansion valve, and the evaporator and it is finally sucked by the compressor again. For the proper functioning of the refrigeration cycle, the refrigerant must be compressed to the pressure corresponding to the saturation temperature higher than the temperature of the naturally available air or water. It is the crucial function that is performed by the compressor. Compression of the refrigerant to the suitable pressure ensures its proper condensation and circulation throughout the cycle. The capacity of the refrigeration or air conditioning depends entirely on the capacity of the compressor.<img src="{{media url="422C8FF7C729C6E9A7416FCA7C2EB508849153E1_large.jpg"}}" alt="" />
-
08/19/2020
Why can a chiller with superior environmental performance reduce the cost of use
Many companies need a low temperature environment when completing production tasks. Because companies use air-cooled chillers to reduce the environmental temperature, the cost is relatively low, and they are very suitable for long-term use by companies.