Pressure PumpsOil-Less Compressor
Vacuum PumpOil-Flooded Rotary Vacuum Pump
Our rotary vacuum pumps are cool running, quiet, and highly efficient.
Providing vacuum to 29.9 in.Hg (0.4 Torr), our compact, direct-drive, oil-flooded pumps operate on a semi-synthetic oil and offer gas ballast as an option. Our multi-stage oil separation system is 99.9+% efficient.
If you want reliability and durability combined with industry-leading performance, you want a Becker rotary vacuum pump.
U 5.100
50 Hz 60 Hz
Nominal Air Flow (CFM) 58.9 70.6
Maximium Vacuum (Torr) 0.075
Horsepower 3.5
Inlet Size (Inches) 1.25
Becker Vacuum Pump U5.100/7
People who bought this item also viewed
NASH Vacuum Pump 2BV2061ONC022P
Iwaki Magnet Pump MX-70VM-34
SEKO Diaphragm Pump AKS603AHP0800
CALPEDA Water Pump TP100/A
TTO Mechanical Seal 65×82×12
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SUNON Fan GM0503PFV2-8
Schneider HMI HMISTU655W
Recent related posts
-
01/09/2021
Be sure to understand these before installing a new fan
The most troublesome thing: the new fan requires indoor and outdoor air exchange, which requires opening holes on the wall or glass. The diameter of the holes in the market is basically concentrated on 150mm\120mm\110mm\100mm.
-
06/14/2020
The new air conditioner takes only 5 minutes to evacuate. What is the effect of air conditioning cooling and heating
The new air conditioner takes only 5 minutes to evacuate. What is the effect of air conditioning cooling and heating
-
06/14/2020
Judgment and common sense of fluoride deficiency in central air conditioning
The amount of fluoride added to large central air conditioners is generally more, and there are more types of refrigerants. The specific amount can be added according to the label on the nameplate. It is necessary to grasp the amount.
-
07/15/2023
What is a Semi-Hermetic Compressor? Everything You Need to Know
If you're in the refrigeration or air conditioning industry, you may have come across the term "semi-hermetic compressor." But what exactly is a semi-hermetic compressor, and how does it differ from other types of compressors?
-
07/04/2020
Danfoss Miele Maneurop compressor MT40 market information
Danfoss Miele Maneurop compressor MT40 market information Meiyoule compressor model; Danfoss Meiyoule Maneurop compressor MT40; Meiyou MT40 horsepower: 3.3hp
-
07/05/2020
Hitachi ultra-low temperature heat pump compressor
Hitachi ultra-low temperature heat pump compressor What are the characteristics of scroll refrigeration compressors? The characteristics of scroll refrigeration compressors are as follows, and their characteristics are also the goals that air-conditioning compressor manufacturing technology is constantly pursuing.
-
03/02/2021
Voltage of servo motor: relationship between voltage and speed of servo motor
1)At high speed, the speed is proportional to the voltage 2) At low speed, the voltage is lower than the decrease of speed;
-
05/16/2023
Why Does My AC Compressor Shut Off After 2-3 Minutes?
In the hot summer, the air conditioner is one of the necessary cooling appliances. When we use the air conditioner in normal times, we should perform maintenance on it from time to time, so as to reduce the failure rate.
-
06/30/2020
Excessive head resistance will cause compressor to trip
Excessive head resistance will cause compressor to trip The existence of compressor failure does not seem to have much to do with the brand. In other words, whether it is a Hitachi compressor, a Copeland compressor, or another brand of compressor, as long as it is used for a long time, there will be some problems of failure. . Compressor tripping is a common fault. When this failure usually occurs, we should comprehensively look for the cause of the failure.
-
06/14/2020
Failure analysis and analysis of other common failures of screw refrigeration compressor
The compression ratio of the screw machine is too large: it proves that this system completely deviates from the design value. The main phenomena are that the temperature of the exhaust temperature is too high, the suction pressure is too low, and the tem 器2 䀀 ᅵ皥