There is no price at present, you can Request a Quote
Power: 30KW
Power: 380V/440V-50HZ/60HZ
Cylinder diameter (mm): 82
Stroke (mm): 55
Number of cylinders: 6
Exhaust volume: 151.6m3/h
Foot mounting size: 305mmx381mm
Dimensions (mm): length 790 width 503 height 443
Suction pipe inner diameter (mm): 54
Exhaust pipe inner diameter (mm): 41.2
Oil charge (liter): 4.75
Suitable for refrigerant: R12 R22 R502 We can also provide the following models
GSD60235VBB332
GYU80385VLR232
GYD60120VAYR4-1
GTD80137VLB3
GED60235VBB432
GTU80421VLYB3-2
GTD80295VLYR4-1
GUU60154VLYR532
GSD80385VAB2
66GE-60Y
GMD80137VLR6
GED80485VBYR432
GTD80120VBYB532
GED60120VAR432
GED60385VBYR4-2
GSD80485VLYB532
GMD80485VAYB5-1
GUD80485VWYB3-1
GMD60385VAYB6-2
4CESH-9
GUD80182VLR5
GMD60235VLR632
GSD80295VLYR232
GYD80182VBYB332
GUD80295VWYR6-1
GED60137VBYB4
GYD60120VAYR6-1
GMD80137VLB5-2
GYD60182VAYR6
GMD80485VWYR6-2
GMU80295VLB3
GYD60485VLR6-1
GED80137VAB6
GUD60385VBR6-2
GSD60295VLYR5
GYD80485VBR4-1
66GE-68
GED80421VBYB4-1
GED80295VLB6
GUD60120VBYB5-2
GED80421VBYR2-1
GUD80485VAR5-2
GSD80385VWB532
GMD60120VLR2
GYD60137VBYB2-1
GTD80137VLR2-2
GUD80385VBB6-2
GMD80235VBYR5-1
GYU60120VLB5
GTU60137VLR632
GED60182VLB632
GTD80120VLB3-2
CSHP7553-70P-40P
GED60182VWYR632
GTD60385VLYR2-2
GED80235VLYR432
F402H/S4N-8.2Y
GMD60182VAYB4-1
GMD60137VLB3
GED80120VBYB6-2
GYD60235VLB232
GUD80154VLR6-2
GMD80120VLYR2
GSD80154VBYB2-1
GUD80182VAB432
GED60182VWYR532
GSD60154VAR232
GED60120VAR4-2
GMU80295VLB2-1
GED60137VBR2-1
GYU60182VLR2-2
GYD80295VBYB3-2
For more information,please contact us freely
Bitzer Compressor 6F-40.2Y-40P
There is no price at present, you can Request a Quote
People who bought this item also viewed
Bitzer Compressor 4CC-6.2-40S
Bitzer Compressor 4VCS-6.2
Bitzer Compressor 4G-20.2
Bitzer Compressor 4DC-5.2-40P
GMCC Compressor PH200X2C-8FTC3
Daikin Compressor 2YC45ZXD
Bitzer Compressor 4CC-9.2-40S
Tecumseh Compressor AE2425Z-FZ3C
CHINT Transformer JBK5-250
YORK Expansion Valve 022G00002-081
ALBRIGHT Contactor SU280B-1268
Sanyo Denki Fan 9GV0412P3J29
ABB Electric Motor M2QA100L8A
FESTO Filter MS9-LFX-1-U
Danfoss Sight Glass SGI6
SPRAGUE Capacitor 25V 680UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Servo Drive MSDA153D2A49
SEKO Diaphragm Pump MM2I179G
KMC Industrial Chain Black green DLC 12
Mitsubishi PLC FX3S-20MT-ESS
HENGYI Vane Pump VP-SF-12-E
Recent related posts
-
09/20/2020
ABB motor low price spot limited time
Shanghai ABB Motor's okmarts.com's ABB motor storage-type spot supplier, was established on Chengdu Airport Road, highway, canal and airport to the whole country. The company has a high-quality, skilled and dedicated team of 30 people.
-
06/13/2020
Before replacing the compressor, remember to do 10 things first, remember ~~
Before replacing the compressor, remember to do 10 things first, remember ~~ 1. Before replacing, you must check the cause of the damage to the original refrigeration compressor and replace the defective parts. Because damage to other components will dir 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ
-
03/21/2024
The Development History and Trends of Servo Systems
The servo system has experienced the development process from hydraulic, pneumatic to electrical. At present, the most widely used is the electrical servo system.
-
08/05/2020
Why does the refrigeration compressor produce overheat protection What matters should be paid attention to in the use of overload protector
The working principle and classification of the overload protector. The overload protector of the compressor for air conditioning generally adopts a snap-type bimetallic protector, which consists of a heating wire,
-
08/28/2020
These hidden corners of the air compressor, so clean it
In summer, for air compressors, every day is the same; as if it is accidental, it is heatstroke and difficult to heat. During the operation of the air compressor, the production of sludge
-
07/27/2020
The use and maintenance operation of screw unit
Parallel unit: generally composed of the same type of compressor, but also can be composed of different types of compressors. It can be composed of the same type of compressor, or it can be composed of different types of compressors (such as piston machine + screw machine). As shown below:
-
07/23/2020
9 usage details that affect the life of air conditioners
1. Clean the air filter frequently. Usually clean once every 2-3 weeks. The steps are: remove the panel; pull out the air filter; clean the air filter. Rinse the air filter under the tap. Since the filter is made of plastic frame and polyester silk, it should not be cleaned with hot water above 40℃ to prevent shrinkage and deformation.
-
11/10/2022
What is an Industrial Fan?
Industrial fans, which can efficiently push a large amount of air and generate super-large air volume. This creates a circulating airflow field in the space.
-
09/16/2020
Application skills of air compressor using oil and gas separator
Abstract: The application technical requirements of the oil-gas separation core used in air compressors, and the problems that occur during the use of the oil-gas separation core are analyzed, and the matters to be noted before installation.
-
06/29/2020
What are the causes treatment and prevention methods of compressor liquid blow
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows: