It is applied to many fields, like Communications equipment Broadband fixed line access Enterprise systems Enterprise projectors Personal electronics Portable electronics .
And the main parameters of this part is: Secure Applications Processor SoC ARM11 CPU.
Additionally, it is green and compliant to RoHS (Lead free / RoHS Compliant).
BROADCOM IC Integrated Circuit BCM5892PC0KFBG
People who bought this item also viewed
Omron PLC ZEN-10C3DR-D-V2
INTEL NIC Card AX210NGW
SANREX Rectifier Module DFA50BA160
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Tecumseh Compressor TPA1413YXA
XINLEI Air Compressor XSZG-15A
HUGGLUNDS Hydraulic Motor A6VM 355
NTK Tool for Metal Cutting CSVR08
Recent related posts
-
06/14/2020
Haikou exploded, the central air conditioner was back
Haikou exploded, the central air conditioner was back, was it wrong Since 2020, the safety of the use of central air conditioning has been widely concerned. From the clustered infections in closed places during the epidemic to the explosion accident in H 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱
-
09/07/2020
What happens if the water-cooled air compressor is short of water
The cooling methods of screw air compressors are mainly divided into two types: air-cooled and water-cooled. Air-cooled air compressors are a relatively common cooling method and are used in small and medium-sized air compressors.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/21/2022
Installation Tips and How to Test a Diaphragm Pump
When installing a pneumatic diaphragm pump, anyone who is not familiar with pumps and pump installations will often make small mistakes that result in costly damages.
-
06/24/2020
The reason why the air conditioner is not cooling
Occasionally encounter the problem that the air conditioner does not cool in life. Don't worry at this time. The reason for the air conditioner not cooling is not very complicated. After understanding the reason for the air conditioner not cooling, you can solve the problem by taking the right medicine.
-
02/09/2024
Hot Air Circulation Tunnel Dryers: Structure, Working Principle, Features and Application
Tunnel dryer is a common drying equipment. It is widely used in food, medicine, chemical and other industries.
-
08/21/2020
Useless for a lifetime. Dehumidification and refrigeration of air conditioners are completely different!
This summer, the heavy rain that has come in New York caught many friends off guard, and the humid and sultry weather made the big guys complain. A small partner told the author that at this time, dehumidification is enough. The air conditioner does not need to be cooled. principle of refrigeration of central air-conditioning chillers
-
09/04/2020
Eight core issues warn compressor companies, and the rapid changes in the market cannot be ignored
When we find that the hot companies a few years ago have become traditional enterprises, you will understand how fast we are in an era of change! Most compressor companies now have a very serious sense of crisis-dealers are difficult to manage
-
02/27/2021
Working principle of servo motor (how servo motor works)
The rotor inside the servo motor is a permanent magnet. The U / V / W three-phase electricity controlled by the driver forms an electromagnetic field. The rotor rotates under the effect of this magnetic field. At the same time, the encoder of the motor feeds back the signal to the driver. The driver adjusts the rotation angle of the rotor according to the comparison between the feedback value and the target value. The accuracy of servo motor depends on the accuracy of encoder (number of lines).
-
06/28/2020
Compressor-Hitachi 3p inverter compressor
Compressor-Hitachi 3p inverter compressor What are the characteristics of scroll refrigeration compressors? The characteristics of scroll refrigeration compressors are as follows, and their characteristics are also the goals that air-conditioning compressor manufacturing technology is constantly pursuing.