Per Package include:
1x Cartridge for YUKEN Vane Pump PV2R12-19-65-L-REAA-41.
1x Cartridge for YUKEN Vane Pump PV2R3-76-L-RAA-31.
Cartridges for YUKEN Vane Pump PV2R12-19-65-L-REAA-41 & PV2R3-76-L-RAA-31
People who bought this item also viewed
Eaton Vickers Vane Pump V20-1S7S-1C11
ANSON Vane Pump PVDF-470-470-10S
KEISTER Vane Pump PV2R2-33-FR
YEESEN Vane Pump PV2R2-33-FR
YUKEN Vane Pump PV2R13-116-10-F-RAAA-40
YUKEN Vane Pump PV2R1-25-L-RAA-43
YUKEN Vane Pump PV2R12-65-28-F-RAAA-40
YUKEN Vane Pump AR22-FR01C-20
TOKYO KEIKI Vane Pump SQP2-10-86-C-18
HONGYI Vane Pump 20V5A-1C22R
TCMC Vane Pump PV2R1-14-F-RAA-02
Yuci Vane Pump PFE-41085-1DT
ITAP Check Valve YORK103-DN40
YUKEN Overflow Valve LBS-16-V-3-A100-14
Daikin Piston Pump V15C12RJPX-95
Boden Gear Pump BAP2B1D12C2Z2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CAMOZZI Air Cylinder 24N2A16A100
SCENERY Vane Pump SQP21-14-7-86CD-18
MUNDORF Capacitor 450V 1UF
PHILIPS Capacitor 047 220UF 63V
SuperRed Fan CHA8012CBS-OA-P
TCS Oil Seal TC 22*38*5
Recent related posts
-
09/10/2020
Questions and Answers on Filter Technology of Compressed Air Purification System
1 Why is the most harmful of oil in the air? Answer: In some places with strict requirements, such as pneumatic control systems, a drop of oil can change the condition of the air holes. Paralyze the production line that was originally running normally and automatically.
-
06/14/2020
Causes and harms of non-condensable gas produced by refrigeration system
Non-condensable gas refers to air, hydrogen, nitrogen, lubricating oil vapor, etc. mixed in the refrigeration system.
-
01/05/2021
Screw compressors and expanders
Screw compressors and expanders From Nikola Stosic, ... Ahmed Kovacevic, in Positive Displacement Machines, 2019 Rotor proportions A general feature of screw compressors is that the pressure difference through them causes high rotor loads and 器2 䀀 ᅵ皥 䖒皦즠Ʋ㊔ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㊞ᰙЀ 呄ᠾ鹨់༹皧
-
01/13/2022
Rotational Inertia of Servo Motor
Servo motor refers to the motor that controls the operation of mechanical components in a servo system. Its rotor speed controlled by the input signal can respond quickly.
-
04/08/2022
Where is the Expansion Valve Located?
Expansion valve, also known as Throttle valve, is an important automatic control component of refrigeration system. It is generally installed between liquid reservoir and evaporator.
-
06/30/2020
How to deal with the faulty host refrigerant system of the compressor
How to deal with the faulty host refrigerant system of the compressor How to deal with a main engine refrigerant system where the compressor has burnt out or failed is a more serious and technically demanding problem than the production of a new main engine. However, it is often neglected by most of the technicians, and even the wrong concept is replaced if they think that it is broken anyway! It causes some disputes that the compressor quality is poor or others use it improperly.
-
07/15/2022
Common Faults of Gear Pump
Cause: A. the rotation direction is opposite; B. the suction or discharge valve is closed
-
08/28/2020
These hidden corners of the air compressor, so clean it
In summer, for air compressors, every day is the same; as if it is accidental, it is heatstroke and difficult to heat. During the operation of the air compressor, the production of sludge
-
06/14/2020
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
-
07/08/2020
This is the key method to solve the leakage problem of fan coil
The fan coil and fresh air system is a widely used air-conditioning method. Because of its flexible layout and the ability of each room to be adjusted independently, it is commonly used in hotels, hotels, office buildings, hospitals and other buildings. However, many problems are often caused by mistakes in construction and design, and the most common one is water leakage.