The rated limiting breaking capacity (ka) kA) Icu AC50Hz 400V 70
The rated running breaking capacity (kA) Ics AC50Hz 400V 70
The minimum value of the rated residual switching-on and switching-off capacity I△m is 25%Icu. Seventeen point five
Use category a.
Total life expectancy with load and no load 2000/8000/10000
Tripper type thermomagnetic type
The residual operating current (adjustable in the fourth gear) I △ n (a) x2: 0.1/0.3/0.5/1; X4:0.2/0.5/1/2
Breaking time (adjustable in third gear) Total breaking time (s) T1: 0.3/0.5/1
Weight (kg) 3P/4P 9.5/11.5
NM8 or NM8S plastic casing circuit breakers are NM8L and NM8SL residual current operated circuit breakers
after being assembled with residual current protection modules conveniently. NM8L and NM8SL series residual
current operated circuit breakers are mainly used in circuits with AC 50Hz, rated voltage up to 400V and
rated current up to 630A A.. Its main function is to provide indirect contact protection for fatal personal
electric shock, and at the same time, it can also be used to prevent electrical fire caused by ground fault
current. It can be used to protect the overload, short circuit and undervoltage of the line, and can also be
used for infrequent switching of the line.
NM8L: Thermomagnetic Residual Current Action Circuit Breaker
NM8SL: Intelligent Residual Current Action Circuit Breaker
Shell level 100A 250A 630A
The rated current (a) is 16, 20, 25, 32, 4050, 63, 80, 100, 125, 160, 180, 200, 225, 250, 315, 350, 400, 500, 630
Note: the maximum value of thermomagnetic residual current operated circuit breaker is 500A A.
3 means 3 poles
4 means 4 poles
4A indicates that the N pole is not equipped with an overcurrent release element, and the N pole is always on;
4B indicates that the N-pole is not equipped with an overcurrent release element, and the N-pole and the other
three poles are combined and divided together (the N-pole is combined first and then divided)
4C indicates that the N pole is equipped with an overcurrent trip element, and the N pole is closed and divided
together with the other three poles (the N pole is closed first and then divided), and the operating current is 1.0In;;
4D indicates that the N pole is equipped with an overcurrent tripping element, and the N pole is always on, and the
operating current is 1.0In;;
M: No code for motor protection: power distribution protection
Normal working conditions and installation conditions
The altitude of the product installation site is 2000m and below;
The external magnetic field of the installation site of residual current operated circuit breaker shall not
exceed 5 times of the earth magnetic field in any direction;
The action value of the intelligent release is not affected by temperature fluctuation. However, the maximum
allowable current of residual current operated circuit breaker is still the same as that of circuit breaker
Environmental temperature.
Damp-heat: the relative humidity of the atmosphere should not exceed 50% when the ambient air temperature is
+40℃, and it can be higher at lower temperature. The monthly average maximum relative humidity in the wettest month is
90%, at the same time. The monthly average minimum humidity in this month is +25℃, and the condensation on the
product surface due to temperature change is considered.
Pollution level: the pollution level is level 3
Characteristics
Using splicing modular design, users can install and maintain themselves without affecting the characteristics
of circuit breakers;
With power indication;
The residual action current and the breaking time of the residual current can be adjusted, which is convenient
for users to choose;
With residual current action indication and reset button, users can quickly judge the action reason of residual
current action circuit breaker.
In addition, the residual current operated circuit breaker cannot be closed without confirming and eliminating
the leakage fault (the reset button is not pressed);
The residual current operated circuit breaker equipped with auxiliary switch can remotely indicate the tripping
of the circuit breaker in case of leakage fault;
High breaking ability and no arcing;
With isolation function and reliable contact indication
Isolation position is in "0" (off) position;
Only when the contact is fully opened can the operating handle indicate the "0" (OFF) position;
Padlocks can only be installed when the contacts are opened;
Rotating the handle will not change the reliability of contact indication;
The isolation function shall ensure the mechanical reliability indicated by the contact, no residual current,
and the terminal on the power supply side can withstand high impact voltage;
Isolation function
Chint Circuit Breaker NM8L-630S/4C
There is no price at present, you can Request a Quote
People who bought this item also viewed
Chint Circuit Breaker NM1LE-250S/4300A
Terasaki Circuit Breaker S400-CF
Siemens Circuit Breaker ED43B050
Siemens Circuit Breaker 3RV2021-4CA20
CHINT Transformer JBK3-63
Eaton Contactor DILM32-10C(24V50/60HZ)
Ferraz Shawmut Fuse A130UD73TTI500
TYCO Relay KUL-4266
Yageo Resistor PNP3WVJT-73-0R1
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Mitsubishi Servo Motor HG-KN43B
ADDA Fan AQ1224MB-F52
Sanyo Denki Fan 109E5724H502
FULOS Air Cylinder CQ2BS12-15
Ebmpapst Fan A2D200-AH18-01
KITZ Butterfly Valve PN16WJA40
Recent related posts
-
08/20/2020
The air conditioner doesn’t cool right after I bought it. I bought a fake brand.
Summer is here, and the sales season for air conditioners is also coming. However, recently some citizens have bought "fake air conditioners." Obviously it is a new product of the well-known brand Midea, why does it stop cooling after just a few days of purchase?
-
07/05/2022
Installation Of Magnet Pump
1.Dropping or subjecting the pump to strong impact may result failure. Handle the pump with care.
-
08/17/2020
What is the principle of the chiller shell and tube evaporator
The cold water shell and tube evaporator is made by expanding two-layer metal plates with high-pressure gas or by mechanical pressing. It can also be made of aluminum alloy die-casting.
-
06/25/2020
Is Hitachi air-conditioning compressor Toshiba brand
"I obviously bought a Hitachi air conditioner. It was discovered that the air conditioner used a Toshiba compressor during maintenance." A few days ago, some media reported this complaint about Hitachi air conditioners. Therefore, many consumers questioned the difference between the case and the internal machine brand: the purchase clearly identified a certain brand, why did you change the brand of the contents inside without telling it? Is there any difference between the products of the two brands? What if the after-sales service is not guaranteed?
-
09/10/2020
Regular maintenance and maintenance of Fusheng air compressor
1. Regular maintenance and maintenance of main components In order to enable the air compressor to operate normally and reliably and ensure the service life of the unit, a detailed maintenance plan must be formulated, manned operations, regular maintenance, and regular inspection and maintenance are required to keep the air compressor unit clean, oil-free, and dirt-free.
-
01/12/2021
Recommend that you use Mitsubishi Electric Air Conditioner
Recommend that you use Mitsubishi Electric Air Conditioner Recently, many businesses recommend Mitsubishi Electric air conditioners, Emphasized the keel motor; Let me introduce you today: Where is the keel motor? Mitsubishi Electric patent: [ 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
08/16/2020
What parameters should be understood when choosing a central air-conditioning air-cooled heat pump unit
You must be familiar with central air-conditioning, but did you know that there is a unit in central air-conditioning called a cold and heat pump unit? The work of central air-conditioning is inseparable from it.
-
07/27/2020
Principles and advantages and disadvantages of screw refrigeration compressors in cold storage
Principles and advantages and disadvantages of screw refrigeration compressors in cold storage Foreword: The cold storage house detailed the classification of cold storage compressors in the article "Introduction to the types of cold storage refrigeration compressors". Among them, screw compressors are mentioned.
-
07/24/2020
Common failures and causes analysis of refrigeration compressors
Common failures and causes analysis of refrigeration compressors The refrigeration compressor is the heart of the entire refrigeration system and the most important in the refrigeration system. Its main function is to compress the low-temperature and low-pressure gas from the evaporator into high-temperature and high-pressure gas to provide source power for the entire refrigeration cycle.
-
12/29/2021
Where is Servo Motor and Servo Drive Used?
With the development of information, communication and automation technology, a wide variety of automatic control devices have been used in industry production and daily life of modern world.