There is no price at present, you can Request a Quote
Circuit breaker 4 a tripper 2.8 ... 4 A A n tripper 52 A, used for motor protection, etc
Class 10, threaded connection, standard switch capacity, with lateral auxiliary switch 1 NO+1 NC
Product brand name SIRIUS
Product Name Circuit Breaker
Product specifications are used for motor protection
Product type name 3RV6
Comprehensive technical data
Structural dimension S00 of circuit breaker
The loss power W totals 6 W typically
The measured value is 690 V at AC when the pollution degree of isolation voltage is 3
The measured value of impulse voltage resistance is 6 kV
Protection level IP
IP20 on the front
connection terminal IP20
dent resistance
comply with IEC 60068-2-27 25g/11 ms
environmental conditions
The installation height is higher than the horizontal plane
the maximum value is 2 000 m.
Ambient temperature
-20 ...+60 c during operation
-50 ...+80 C during transportation
Relative air humidity during operation 10 ... 95%
main circuit
The number of poles is used for the main circuit 3
Settable current action value 2.8 ... 4 A of overload tripping of current control
Working voltage
the measured value is 690 V
the maximum measured value is 690 V at AC-3
The measured working frequency is 50 ... 60 Hz
The measured working current is 4 a.
Working current
AC-3 AC-3
the measured value is 4 A at 400v
Switching frequency
the maximum value at AC-3 is 15 1/H.
auxiliary circuit
The structure of the auxiliary switch is horizontally placed
Protection and monitoring functions
Trip level CLASS 10
Over-current release specification heat
Working short circuit current (Ics) breaking capacity AC
the measured value at 400v is 100 kA
Breaking capacity of limit short circuit current (Icu)
the measured value at 400 V at AC is 100 kA
Current action value
52 A of short circuit release without delay
Protection device to prevent short circuit from causing damage to switching device.
Product function short circuit protection yes
Specification of short circuit release magnetic
Mounting/fixing/outline dimensions
The loading position is arbitrary
Fastening type: screw fastening and snap fastening on 35mm mounting rail according to DIN EN 60715
Height 97 mm
Width 45 mm
Depth 96 mm
Siemens Circuit Breaker 3RV6011-1EA15
There is no price at present, you can Request a Quote
People who bought this item also viewed
AEG Circuit Breaker MBS 25 0.63-1A
Siemens Circuit Breaker 5SY6310-7CC
Siemens Circuit Breaker 3RV2021-4BA20
Siemens Circuit Breaker 3RV1011-0CA10
Siemens Circuit Breaker 3RV1011-0KA10
ABB Circuit Breaker 2CDS251001R0045
CHINT Transformer TDGC2J-15
Schneider Contactor LP1K09008BD
OBO Surge Protection Device FLD 5
LINDNER Fuse D01-50A
TAIAN Relay RHU-10K1/454 9-12.5A/610
UniOhm Resistor 1206W4J0564T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron PLC C4K-OR2
FOTEK Sensor PM18-05N-M12
Honeywell Sensor CP18D1DNLC
CKD Solenoid Valve 4GE229-E2C
Recent related posts
-
01/05/2021
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes.
Refrigerant, compressor, expansion valve (flow control device), evaporator, condenser, pipes and tubes. Skematic of Compression Refrigeration System
-
08/05/2020
The purpose, method and choice of cold storage system defrosting
The purpose, method and choice of cold storage system defrosting
-
07/04/2020
Danfoss Miele Maneurop compressor MT40 market information
Danfoss Miele Maneurop compressor MT40 market information Meiyoule compressor model; Danfoss Meiyoule Maneurop compressor MT40; Meiyou MT40 horsepower: 3.3hp
-
11/18/2021
Rosemount Transmitter Series 1151, 2088, 2051, 3051CA, 3051S and the Differences
Rosemount pressure transmitter is a kind of general pressure transmitter. It is manufactured according to the law of electromagnetic induction and JB/T9248-1999 standard.
-
06/13/2020
Refrigeration compressor industry market competition status and development trend research report
In recent years, China's refrigeration compressor industry has also developed rapidly due to downstream demand. During the "Eleventh Five-Year Plan" period, the localization rate of complete sets of refrigeration compressors in all major fields of industr ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦
-
09/09/2020
Nine misunderstandings in the selection and use of air compressor lubricants
Good lubrication will give full play to the overall efficiency of the air compressor unit in operation, improve equipment efficiency, ensure production quality, and reduce maintenance costs and downtime, which is of inestimable significance.
-
06/13/2020
The role of lubricating oil
The role of lubricating oil 1) A dynamic seal is formed between the screw and the compression chamber and the male and female screws to reduce the leakage of refrigerant from the high-pressure side to the low-pressure side during the compression process.
-
10/14/2021
Factors to Consider When Selecting Rotary Encoders
In a series of modern machinery industries like construction, building materials, mining, engineering vehicles, metallurgy, water conservancy, port machinery and other fields related to large heavy equipment, the reliability and safety of equipment comes first in process control.
-
02/19/2023
The Structure, Characteristics, and Notices for Use of Butterfly Valve
Butterfly valve consists of valve case and valve body. This valve, which is characteristic of rotatable disc or double plate, can be used to cut off water. Its axis of rotation is perpendicular to the direction of water flow.
-
07/14/2023
Troubleshooting a Refrigerator Compressor Running But Not Cooling: A Comprehensive Guide
The refrigerator is an essential appliance in every home, keeping our perishable food items fresh and safe for consumption. However, when the refrigerator compressor is running but the refrigerator is not cooling