Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.25 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.18...0.25 A |
Suitable for induction motors with P | 0.06 kW |
Instantaneous overcurrent releases | 3.3 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.233 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.18...0.25 A
N-release 3.3 A Screw terminal Standard switchingcapacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 - +80 degrees centigrade
during transport -50 - +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.18 - 0.25
operating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.25 A
operating current
at AC-3 at 400 V rated value 0.25 A
operating power at AC-3
at 230 V rated value 37 W
at 400 V rated value60 W
at 500 V rated value90 W
at 690 V rated value120 W
operating frequency at AC-3 maximum 15 1/h
number of CO contacts for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 3.3 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.25 A
at 600 V rated value0.25 A
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0CA10
People who bought this item also viewed
Siemens Circuit Breaker 5SY4332-7
Siemens Circuit Breaker 3VU1300-1MG00
Siemens Circuit Breaker 3RV1011-1EA10
Siemens Circuit Breaker 3RV1011-1CA15
ABB Circuit Breaker GDA202 A-25
Siemens Circuit Breaker 3RV1021-0AA10
Siemens Circuit Breaker 3RV2021-0JA10
Siemens Circuit Breaker 3RV1121-1KA10
Amgis Transformer L01-6303
Fuji Contactor NAT-60F
DEHN Surge Protection Device DGP C MOD
Ferraz Shawmut Fuse PC31UD69V500A
CRYDOM Relay H12WD48110
Siemens Resistor 3RT1926-1BB00
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
MINDMAN Air Cylinder MCJT-12-16-45M
Shilin Contactor S-P400T
Nidec Fan W40S12BHD5-07T046
Recent related posts
-
08/07/2020
Technical post: Use icons to tell you the difference between constant speed and frequency conversion!
The fixed speed air conditioner means that the speed of the internal compressor motor is constant and the temperature is adjusted by switching the compressor on and off.
-
08/17/2020
Analysis of 4 major reasons for the high energy consumption of building HVAC systems
1. Analysis of the high energy consumption of the building HVAC system The reasons for the high energy consumption of building HVAC systems are mainly reflected in the following aspects:
-
10/30/2021
VFD Troubleshooting: 10 Simple Methods to Master
At present and in the future, the maintenance of the electrical control equipment, VFD (Variable Frequency Drive) will become the professional knowledge that all electricians need to master.
-
07/20/2023
What is a Water Source Heat Pump (with Water Source Heat Pump Diagram)
A water source heat pump (WSHP) is an HVAC system that uses the natural heat in water to provide heating, cooling, and hot water for commercial and residential buildings.
-
06/14/2020
Vane compressor
The vane compressor is directly driven at a very low speed. The rotor is the only continuously running component. There are a number of slots cut along the length direction, in which there are inserted vanes that can slide on the oil film. The rotor is in 器2 䀀 ᅵ皥 䖒
-
07/20/2020
How does a refrigeration compressor work? Introduction to the working principle of a refrigeration compressor【Detailed explanation】
Refrigeration compressors are devices that are often used in our industrial industry and in life, such as air conditioners, refrigerators, etc., all have a refrigeration function. Traditional refrigeration equipment must be equipped with a refrigeration compressor, and the quality of the refrigeration function is concerned with refrigeration The quality of the compressor, so we must understand the performance of the refrigerator when we buy refrigeration products. Let's take a look at the specific content of the refrigerator.
-
06/29/2020
The core problem of compressor operation
The core problem of compressor operation The scroll compressor is a volumetric compression compressor, and the compression component is composed of a movable scroll and a static scroll. Its working principle is to use the relative orbital motion of the movable and static scrolls to form a continuous change in the enclosed volume, so as to achieve the purpose of compressing gas.
-
09/09/2020
The relationship between air compressor power, pressure and volume flow
Air compressor terminology: What is the relationship between air compressor power, working pressure and volume flow? First, let's first understand the definition of the three.
-
08/29/2020
Factors affecting the quality of air compressors human, machine, material, method, environment, and measurement....
First of all, let's understand what is 5M1E?<br></br> A) Man: The operator’s knowledge of quality, technical proficiency, physical condition, etc.;<br></br>
-
04/06/2023
What Type of Compressor is Used in Domestic Refrigerators
We all know that in addition to electricity, refrigerators rely on compressors to maintain normal operation. The compressor is like the heart of the refrigerator.