There is no price at present, you can Request a Quote
Toggle position discrimination: 2 bit single electronic control
Port size: Rc1
Voltage: DC24V
Manual device: Locking type
Wire connection: Round Terminal Box
We can also provide the following models
AB41EX4-02-7-C313A-DC12
4GD359R-C8-4
GFGB51-6-3-13TRN-3
4GB429-C10-3
M3MA010-T4-D22-12-DC5V
FWD11-8N-B2CB-AC200V
MN4GA230R-C4-2
N4GD230R-C8-E03-4
AD12-10A-L5I-AC100V
GFLB41-7-4-B3RS-1
GFAB55-7-8-12G-4
AB41E4-3N-6-B3MBCN-AC100V
SNS-1-15A-MBNLK-3
M4GB319R-C6-1
MN4GE120R-CX-E22-2
M3MA019-T4-C-4-3
N4TB249-H8-L-5
MN4GD120R-C4-3
P5136-M0E-S-AC200V
AB31-1N-5-M3NABFS-DC48V
AB41-04-1-CDS-AC200V
M4GA429-10N-E21F-1
AB41EX4-03-3-F311-DC12
ADK11-20G-P3N-AC100V
AB41E4-03-1-D3LACN-DC24V
AB41EX4-02-7-E510A-AC100
4GA440-10-E2Q-4
MN4GE210R-C4-E22J-4
4GA410-C10-E21Z3-5
4GA429-10-E21F-1
4F340EX-08-G9-R-AC110V
GMFZ9-HX4L-HY6UDU
4GA450-C8-E03-4
GFGG41-8-3-12CRN-3
AB41EX4-02-1-L311AB-DC48
N4GE210R-C8-E02-3
M4GD380R-C8-1
P5126-M0EV-S-AC48V
AB42E4-3N-2-03L-DC12V
GFGG51-8-5-13RRN-3
3PA210-GS6-B-2
MN4GA229R-C8-3-1
M5136-NL-SL-DC48V
MN4S0660-C4-M1-4
FLB41-15-7-B2CHB-2
M4GA459-C8-E0NA-4
ADK11-25G-M5IBFZ-AC100V
GFAB41-5-6-12G-4
M4GE120R-00-E22J-3
AD11-20A-L2H-AC100V
AB42E4-2G-5-B5LABCN-AC100V
MN4TB189-H4-M1LT10K-4
M4GE150EX-CX-R1H-3-4
4SA030-T4-M1D01-DC5V
FGB41-10-7-13TRA-4
MN4GD110R-M5-E23J-2
AB42-02-7-A-DC24V
3PB110-06-M1LSS-AC115V
4KA230-08-AC24V
FAG33-6-1-12CHN-2
GFAG41-1-10-12C-1
4GA430-CX-E0K-1
M3MA089-T4-D01-13-DC6V
4F630-20G-DC48V
AB41EX4-03-7-E49B-DC48
AB42E4-02-4-B3LCN-AC200V
AB42E4-03-2-D5TACN-DC24V
AB41EX4-02-5-C310A-DC48
AB41E4-02-7-C5TABCN-DC100V
AP21-40A-K3I-AC100V
PVS-80A-210-AC100V
4GA420-C10-E22JQ-3
MN4GD139R-CX-E02J-4
MN4GE219R-CX-E2-3
P5136-M1DR-DC48V
AB31-2G-5-P3IABFS-DC24V
3QE110-M5-ME03A-1
MN4GE130R-CD6-1
M4TB320-HX-LT10-5
AB41EX4-02-1-L59A-DC100
AB41-03-4-H3AABHS-DC24V
AP21-40A-05N-AC200V
M4GD420EX-10-R1-8-4
GMFZ5-HX5-HY3DDU
M4GA310R-M5N-1
MN4GB240R-CD6NC-2
N4GE220R-CX-E02-2
AB42E4-03-5-D3LBCN-DC12V
AB31-1N-2-H3NABFS-DC24V
MN4TB230-H6-M1T10K-4
AB31-2N-7-P5MABD-AC200V
4GA429-C8-E3K-4
M4GA439-10N-E22F-5
M4GE120EX-00-RNH-6-4
CMFZ2-HX4Z-HY3EUD
M4GD380EX-C6-RNF-8-4
4GE229R-08-E02J-3
GAB352-1-7-R3AAGSZ-DC100V
AB42E4-03-7-03TBCN-AC100V
N4KA120A-HX-AC220V
AB42E4-3N-1-C5LAB-DC100V
N4TB220-HX-LT10-5
4GA430-10-E21F-3
M4GE210EX-C4-RNH-3-4
N4KA229-H8-AC115V
CMF17-02H-MO-HY1T
GMFZ3-HX6T-HY3UDU
AB41E4-02-1-C3TCN-AC200V
AB41EX4-03-2-0510AB-AC100
GFWG31-1-9-D2C-1
AB42E4-3G-1-B3MCN-AC100V
AB31-2G-2-J3ABHS-DC12V
M5122-M6VR-M5-L-DC48V
AB41E4-2N-2-B5MAB-DC12V
FGB31-6-3-13RR-4
AB42E4-02-5-D3LA-DC100V
ADK11-10G-05A-DC24V
GFAB45-7-10-12CS-1
AB41E4-03-7-05L-AC200V
M4GA440-C10-E23A-1
AB41EX4-03-3-R510B-DC12
AB42E4-2N-2-03M-AC200V
SNP-1L-20A-02KSMB4-3
AB41EX4-03-5-L311A-AC100
AP11-25G-N5I-AC200V
ADK11-25G-M3JBDSZ-DC12V
AD21-32A-J4A-AC100V
M4GA420-10N-E1Q-1
M4GA420-10G-E00Q-4
M5136-NLR-SL-DC24V
CMFZ6-HX4L-HY5BDU
AB41EX2-03-3-C4G10B-AC100V
AP22-50F-B2E-AC200V
AB31-1N-6-L3JABES-DC48V
PV5G-6-FG-S-1-A03
M4GE320R-CL8-E20-1
AB31-2N-2-L5NABF-AC200V
MN4TB129-HX-M1LT10K-6
4GA450-CX-E20K-1
AB41EX4-03-6-F49-DC24
AB41EX4-03-3-M411AB-AC100
M4GA449-10-E23JA-5
HVB412-4RM-3-2G-DC24V
SNP-1L-15A-02GLB4-2
AP12-20N-06H-AC100V
AB41E4-03-6-C5TAB-DC48V
4GB420-10N-E1K-4
M4GE249R-CD6-E0-3
AD21-50A-M6G-AC100V
AB41EX4-03-6-M49-DC24
M4SB020-GS4-M1D20-DC6V
GAB352N-5-4-H3AAGSZ-DC12V
M4GD210R-CX-E00-1
AD22-40A-02H-DC24V
AB42E4-2G-5-D3TBCN-DC24V
4TB330-08-M1-2
For more information,please contact us freely
CKD Solenoid Valve 4F710-25-B-DC24V
There is no price at present, you can Request a Quote
People who bought this item also viewed
CKD Solenoid Valve GAG412-1-0-B-AC110V
CKD Solenoid Valve FS2-03-4-AC220V
CKD Solenoid Valve EXA-C12-02CB-3
CKD Solenoid Valve 4GD359-C8-BC-3
KOGANEI Solenoid Valve A010-4E1-3W
CHELIC Solenoid Valve SNK-8203
KOGANEI Solenoid Valve 240-4E1-39-36W
Danfoss Compressor SZ240A4CBI
TOGI Transformer TRH1K-21S
SUNX Sensor FT-E20
Danfoss Expansion Valve 068U2072
BROAD-OCEAN Electric Motor Y6S643C01
RISUNY Piston Pump V23B4R
KCL Vane Pump VQ225-52-26-F-RARA-02
Danfoss Sight Glass SG5S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Panasonic Air Conditioner HE27FN1
Recent related posts
-
01/04/2021
Compressors
Compressors The largest compressor program for commercial and industrial refrigeration, air-conditioning and heat pump applications. Since the end of the 19th century, it has been our business to cool processes and products, and to control the tempera 器2 䀀 ᅵ皥 䖒皦즠Ʋ㊔ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㊞ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ќ 識 �僬㣢ᐲ
-
06/14/2020
Knowledge of maintenance of air energy heat pump
Knowledge of maintenance of air energy heat pump The air energy water heater is composed of an outdoor unit and an insulated water tank. The outdoor unit is called an air energy heat pump unit.
-
09/09/2020
The influence of machining on fatigue life
The residual compressive stress introduced by shot blasting/shot peening is a percentage of the final tensile stress strength, and this ratio increases as the strength/hardness of the part material itself increases. High-strength/hardness metals are more brittle and more sensitive to surface defects. Shot blasting/shot peening will allow these high-strength metals to be used in fatigue-prone working conditions. Aircraft landing gear is usually designed with a fatigue strength of 300 ksi (2068 MPa), combined with shot blasting/shot peening.
-
06/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
07/14/2020
Talk about explosion of air conditioner and refrigerant
As a household appliance, air conditioners are gradually going to thousands of households. Air conditioners have a history of hundreds of years, so we not only have to ask whether the early production of air conditioners has not exploded? Why the explosion of air conditioners happened in recent years has a close relationship with the refrigerants used in air conditioner production.
-
09/09/2020
Features of variable frequency screw air compressor
Motor: Special low-speed compressor motor, SKF bearings, insulation class F, protection class IP54, to ensure trouble-free operation. The efficiency is 3-5% higher than similar products.
-
01/04/2023
Parameters of the Solenoid Coil
The solenoid coil is tightly wrapped up on a core to form a solenoid. The main parameter of the solenoid coil is the size of the inductance.
-
06/14/2020
Workflow of single screw air compressor startup and commissioning
Workflow of single screw air compressor startup and commissioning
-
11/19/2023
Difference in 2 Pin, 3 Pin and 4 Pin Computer Fans: Which is better?
If a computer does not have a radiator, its internal temperature will be infinitely high, and eventually the hardware will be burned directly. Whether it is for the CPU, graphics card, chassis, or power supply, heat dissipation is required.
-
08/11/2020
Principles and characteristics of heat recovery series air conditioning units
With the growth of China’s economic power and the continuous improvement of people’s material and cultural living standards; the rapid development of high-rise buildings,